Zdeněk Kopecký

Dr. Zdeněk Kopecký


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 October 2020 in Journal of Nuclear Engineering and Radiation Science
Verified
Journal Article
Closed access
PDF file
ZMZdeněk Matěj
Zdeněk Matěj
FMFilip Mravec
Filip Mravec
AJAles Jancar
Ales Jancar
MKMichal Košťál
Michal Košťál
FKFrantišek Kučera
František Kučera
OPOldřich Pecák
Oldřich Pecák
In this work, we compare the pulse-shape discrimination (PSD) properties of newly developed liquid scintillator LSB-200, EJ-299-33A, BC-501A, stilbene, p-terphenyl, and Hidex Aqualight in neutron field generated by the LVR-15 reactor with silicon filter utilization. Pulses from the scintillators are processed by the Neutron-Gamma spectrometer. This spectrometric system with fast digitizer card contains two analog–digital converters with a resolution of 12 bits and sampling frequency 500 × 106 Hz. For photomultiplier linearity improvement, the active divider has been used. Measured data from scintillators have been processed using the integration method and compared. The results are presented.

22 October 2024 in Instruments
Verified
Journal Article
Open access
PDF file
AJAles Jancar
Ales Jancar
ZKZdeněk Kopecký
Zdeněk Kopecký
JČJiří Čulen
Jiří Čulen
ZMZdeněk Matěj
Zdeněk Matěj
MKMichal Košťál
Michal Košťál
In this work, we studied the light-output properties, efficiency function, as well as the pulse-shape discrimination (PSD) capability of p-Terphenyl scintillator. The selected solid cylindrical scintillation detector has a thickness of 45 mm and a diameter of 45 mm. Recently presented studies of light-output functions have only been measured for low-neutron energies. Our motivation has been to determine the light output function for p-Terphenyl scintillator more accurately over a wider neutron energy range. The measurements have been carried out with mono-energetic neutron beams in the wide energy range from 1.1 to 19 MeV. The neutron–gamma spectrometric system which we developed has been used for the measurement. The input analog signal from the detector was digitized with a fast 12-bits analog to digital converter with a sampling frequency of 1 GHz. Measured data from the detector are processed into the gamma and neutron spectra. The accurate light output function for the p-Therphenyl scintillator has been calculated. The pulse-shape discrimination capability, as well as the detection efficiency, of a p-Terphenyl scintillator are lower in comparison with a NE-213 equivalent detector.

23 August 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
AJAles Jancar
Ales Jancar
ZKZdeněk Kopecký
Zdeněk Kopecký
JČJiří Čulen
Jiří Čulen
ZMZdeněk Matěj
Zdeněk Matěj
MKMichal Košťál
Michal Košťál
In this work, we studied light-output properties, efficiency function as well as PSD capability of p-Terphenyl scintillator. The selected solid cylindrical scintillation detector has a size of (45 x 45) mm with PSD properties. Recently presented studies of light-output functions have been meas-ured only for low neutron energies. Our motivation has been to determine more accurate the light output function for p-Terphenyl scintillator over a wider neutron energy range. The measurements have been carried out with mono-energetic neutron beams in the wide energy range from 2.5 to 19 MeV. The neutron-gamma spectrometric system, which we developed has been used for the measurement. The input analogue signal from the detector is digitized with fast 12-bits analogue to digital converter with sampling frequency of 1 GHz. Measured data from the detector are processed into gamma and neutron spectra. The light output function for protons has been determined by finding the position of the protons for given neutron energies. The more accurate light output function for p-Therphenyl scintillator has been calculated. The pulse-shape discrimination capability as well as efficiency of p-Terphenyl scintillator in comparison with NE-213 equivalent detector is lower.