A shield made of barium sulfate for interventional angiography was analyzed for X-ray spectrum transmission and radiation dose rate using an anthropomorphic phantom to evaluate radiation dose reduction. The barium sulfate comprised nanoparticles for a 2-mm-thick layer, and the shield was 40 × 60 cm in size with a lead equivalent of 0.06 mmPb. X-ray energy spectra were measured before and after the use of barium composite shields with the anthropomorphic phantom. The radiation dose rate was reduced by 20% from 55 to 44 mR/min (p < 0.05) using the barium composite shield, and by 32.4% from 526 to 355.7 mR/min at the flank (p < 0.05). Using an eco-friendly radiation shield mixed with barium sulfate, the radiation dose in the angiography system was reduced by 20–32.4%. The image quality was maintained and these results can be used to appropriately reduce the radiation dose in clinics.
22 May 2020 in Radiation Effects and Defects in Solids
The purpose of this study was to evaluate the dose and image to assess a shielding made of barium sulfate for the protection of supersensitive radiation eye lens and superficial breast during CT scanning. Doses were measured by CT scan of the head and chest phantoms with a polymethylmethacrylate (PMMA) phantom consisting of holes (designated in sequence at 0°, 90°, 180°, and 270°). Dose measurement of the eye lens was performed using a 16 cm head phantom and chest breast dose measurement was performed using a 32 cm PMMA body phantom. The dose was measured using a barium shield and the dose reductions in the head and chest phantoms were calculated by comparing the doses of the reference. For image evaluation, HU and noise on the left and right sides were measured by dividing them into the anterior, lateral (90°, 270°), and posterior positions. To evaluate the barium shielding image, the image was evaluated by selecting a surface plot using the ImageJ program. The head phantom dose decreased by 12.4% maximum in the anterior position (0°) and the chest phantom showed a decrease of 31.37% in the anterior (0°) and 33.63% in the lateral (90°) positions. In the comparison of noise of the image, the head phantom showed an increase of 50.43% in the anterior position. There was a significant difference in dose at positions other than the lateral (270°) and posterior (180°) positions (p < 0.05). Scanning the chest phantom in the anterior position increased the noise by up to 90.66% in the noise comparison (270°) and the posterior (180°) position showed significant differences in image (p < 0.05). In the CT scan using a barium-based shielding agent, the dose was reduced by 3.3–12.4% in the head and 3.62–33% in the chest. The barium shielding agent should be used for the examination by reducing the dose and maintaining the image quality by applying it efficiently during CT examination.
15 June 2011 in Journal of the Korean Physical Society
There is a concern regarding the adverse effects of increasing radiation doses due to repeated computed tomography (CT) scans, especially in radiosensitive organs and portions thereof, such as the lenses of the eyes. Bismuth shielding with an adaptive statistical iterative reconstruction (ASIR) algorithm was recently introduced in our clinic as a method to reduce the absorbed radiation dose. This technique was applied to the lens of the eye during CT scans. The purpose of this study was to evaluate the reduction in the absorbed radiation dose and to determine the noise level when using bismuth shielding and the ASIR algorithm with the GE DC 750 HD 64-channel CT scanner for CT of the head of a humanoid phantom. With the use of bismuth shielding, the noise level was higher in the beam-hardening artifact areas than in the revealed artifact areas. However, with the use of ASIR, the noise level was lower than that with the use of bismuth alone; it was also lower in the artifact areas. The reduction in the radiation dose with the use of bismuth was greatest at the surface of the phantom to a limited depth. In conclusion, it is possible to reduce the radiation level and slightly decrease the bismuth-induced noise level by using a combination of ASIR as an algorithm process and bismuth as an in-plane hardware-type shielding method.
15 February 2011 in Journal of the Korean Physical Society