Yan Xu

Dr. Yan Xu


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 March 2019 in Energies
Verified
Journal Article
Open access
PDF file
WJWaqas Javed
Waqas Javed
DCDong Chen
Dong Chen
Mohamed Emad FarragMohamed Emad Farrag
Mohamed Emad Farrag
YXYan Xu
Yan Xu
Low voltage direct current (LVDC) distribution has gained the significant interest of research due to the advancements in power conversion technologies. However, the use of converters has given rise to several technical issues regarding their protections and controls of such devices under faulty conditions. Post-fault behaviour of converter-fed LVDC system involves both active converter control and passive circuit transient of similar time scale, which makes the protection for LVDC distribution significantly different and more challenging than low voltage AC. These protection and operational issues have handicapped the practical applications of DC distribution. This paper presents state-of-the-art protection schemes developed for DC Microgrids. With a close look at practical limitations such as the dependency on modelling accuracy, requirement on communications and so forth, a comprehensive evaluation is carried out on those system approaches in terms of system configurations, fault detection, location, isolation and restoration.

28 May 2020 in Nanomaterials
Verified
Journal Article
Open access
PDF file
QLQing Liu
Qing Liu
SZShihang Zhang
Shihang Zhang
YXYan Xu
Yan Xu
In this study, the dense cloud-like structured CuS nanoparticles were successfully prepared using a simple two-step hydrothermal method. The experimental temperature was the most important factor that affected the microstructure and surface functions of CuS/C. Therefore, the CuS/C electrodes were synthesized at different temperatures (80 °C, 120 °C, and 160 °C). Subsequently, their crystallographic phase and morphologies as well as the structure of the as-prepared electrodes were analyzed in detail. The electrode prepared at 120 °C (CuS/C-120) was determined to have a perfect microstructure, high specific capacitance, and good rate performance. To further improve the electrochemical performance of this electrode, it was combined with polyaniline (PANI) to obtain a CuS/C-120@PANI electrode via the cyclic voltammetric electrodeposition method. The CuS/C-120@PANI electrode exhibits a specific capacitance of 425.53 Fg−1 at a current density of 1 Ag−1 and a good cycling stability of 89.86% after 3000 cycles. The perfect architecture of CuS/C-120@PANI maximizes the synergistic effect between its different components and provides abundant electrochemically reactive sites, promoting the diffusion and transfer of electrolyte ions during the electrochemical reaction processes. Detailed analysis shows that the CuS/C-120@PANI electrode has great potential for use in high-performance energy storage devices.

21 October 2022 in Energies
Verified
Journal Article
Open access
PDF file
TMTianxiang Ma
Tianxiang Ma
ZHZiqi Hu
Ziqi Hu
YXYan Xu
Yan Xu
HDHaoran Dong
Haoran Dong
Flexible DC distribution networks have a strong capacity for new energy consumption and have received extensive attention from scholars in recent years, but fault location for DC distribution lines is a difficult task. To solve this problem, we propose using a comprehensive grey correlation degree analysis to analyze the similarity of aerial mode traveling differential current waveforms at the first and last ends of a DC line, thus achieving fault location by obtaining the optimal time shift. Additionally, we built a six-terminal flexible DC distribution network model in Matlab/Simulink for simulation and validation, showing that the method can complete the rapid and accurate location of all types of faults on a DC line, and that it possesses an anti-transition resistance capability, making it suitable and highly reliable for cases of low sampling frequency.

28 August 2024 in Electronics
Verified
Journal Article
Open access
PDF file
MWMing-Yuan Wang
Ming-Yuan Wang
YXYan Xu
Yan Xu
Flexible DC power grids are widely recognized as an important component of building smart grids. Compared with traditional AC power grids, flexible DC power grids have strong technical advantages in islanding power supplies, distributed power supplies, regional power supplies, and AC system interconnection. In multi-terminal flexible DC power grids containing renewable energy sources such as solar and wind power, due to the instability and intermittency of renewable energy, it is usually necessary to add energy storage units to pre-regulate the power of the multi-terminal flexible DC power grid in islanded operation. Aiming at the important problem of large current impact and serious consequences when the flexible DC distribution network fails, a combined location method combining an improved impedance method (series current-limiting reactors at both ends of the line to obtain a more accurate current differential value) and a particle swarm optimization algorithm is proposed. Initially, by establishing the enhanced impedance model, the differential variables under the conditions of inter-electrode short-circuit and single-pole grounding fault can be obtained. Then tailor-made fitness functions are designed for these two models to optimize parameter identification. Subsequently, the iterative parameters of the particle swarm optimization algorithm are fine-tuned, giving it dynamic sociality and self-learning ability in the iterative process, which significantly improves the convergence speed and successfully avoids local optimization. Finally, various fault types in a six-terminal DC distribution network are simulated and analyzed by MATLAB, and the results show that this method has good accuracy and robustness. This research provides strong theoretical and methodological support for improving the safety and reliability of DC distribution systems.

3 October 2022 in Energies
Verified
Journal Article
Open access
PDF file
YXYan Xu
Yan Xu
ZHZiqi Hu
Ziqi Hu
TMTianxiang Ma
Tianxiang Ma
Compared with the pole-to-pole short circuit, the fault characteristics are not obvious when a monopolar grounding fault occurs in a DC distribution network, and it is difficult to locate the fault accurately. To solve this problem, this paper proposes a fault location method based on improved ReliefF and Weighted random forest (WRF). The 24 time and frequency-domain fault features of the postfault aerial mode current are calculated, and the most useful features are selected to form the optimal feature subset for input to the fault location estimator. In this paper, the ReliefF algorithm is utilized for automatic feature selection and obtaining the weights of features. In addition, the WRF algorithm is used to build the fault location estimator. Considering the fault location, fault resistance, noise and time window length, the Matlab/Simulink simulation platform is used to simulate the fault situation and compare it with other algorithms. The simulation results show that the average positioning error of the fault location method is less than 0.1%, which is not affected by the fault resistance and has strong robustness.

30 June 2026 in Electricity
Verified
Journal Article
Open access
PDF file
YXYan Xu
Yan Xu
CYChaoqiang Yu
Chaoqiang Yu
JZJianTao Zhap
JianTao Zhap
To address the transient frequency limit violations triggered by the low-inertia characteristics of temporary islanded microgrids formed under extreme disasters, this paper proposes a multi-source collaborative two-stage robust optimization day-ahead scheduling model considering dynamic frequency constraints. Firstly, a collaborative architecture encompassing emergency power vehicles, grid-forming energy storage systems, and flexible loads is constructed. Through collaborative scheduling in the day-ahead pre-scheduling and real-time re-scheduling stages, this architecture effectively avoids the exorbitant costs of physical load shedding under extreme conditions. Secondly, to overcome the limitations of traditional robust box uncertainty sets—which ignore temporal correlations, tend to cause non-physical high-frequency oscillations, and hinder algorithm convergence—a time-correlated uncertainty set based on state-transition auxiliary variables is designed to accurately capture the continuous evolution characteristics of meteorological disturbances. The column-and-constraint generation algorithm is utilized for the solution methodology, combined with the big-M method to transform the subproblem containing bilinear terms into a mixed-integer linear programming model for efficient solving. Simulation results on a modified 33-node test system demonstrate that the proposed model effectively filters out high-frequency oscillation trajectories and significantly improves computational efficiency. Under the worst-case temporal disturbances, the transient frequency drop and the rate of change in frequency are strictly controlled within safe thresholds. Compared to deterministic scheduling and traditional box-based robust models, the proposed scheme effectively balances system security and economic efficiency, demonstrating exceptional system resilience and defense capabilities against varying prediction errors.