Jeff Ketterling

Dr. Jeff Ketterling

orcid

Research Focus & Metrics

Academic Career Length

31Years (1996-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2003 in Ultrasound in Medicine & Biology
Verified
Journal Article
Closed access
FLFrederic L. Lizzi
Frederic L. Lizzi
RMRobert Muratore
Robert Muratore
CDCheri X. Deng
Cheri X. Deng
JKJeff Ketterling
Jeff Ketterling
SAS.Kaisar Alam
S.Kaisar Alam
AKAndrew Kalisz
Andrew Kalisz

22 January 2015 in Investigative Ophthalmology & Visual Science
Verified
Journal Article
Open access
PDF file
JMJonathan Mamou
Jonathan Mamou
CWChristianne A. Wa
Christianne A. Wa
KYKenneth M. P. Yee
Kenneth M. P. Yee
RSRonald H. Silverman
Ronald H. Silverman
JKJeff Ketterling
Jeff Ketterling
JSJ. Sebag
J. Sebag
Purpose.: Clinical evaluation of floaters lacks quantitative assessment of vitreous structure. This study used quantitative ultrasound (QUS) to measure vitreous opacities. Since floaters reduce contrast sensitivity (CS) and quality of life (Visual Function Questionnaire [VFQ]), it is hypothesized that QUS will correlate with CS and VFQ in patients with floaters. Methods.: Twenty-two eyes (22 subjects; age = 57 ± 19 years) with floaters were evaluated with Freiburg acuity contrast testing (FrACT; %Weber) and VFQ. Ultrasonography used a customized probe (15-MHz center frequency, 20-mm focal length, 7-mm aperture) with longitudinal and transverse scans taken in primary gaze and a horizontal longitudinal scan through premacular vitreous in temporal gaze. Each scan set had 100 frames of log-compressed envelope data. Within each frame, two regions of interest (ROIs) were analyzed (whole-central and posterior vitreous) to yield three parameters (energy, E; mean amplitude, M; and percentage of vitreous filled by echodensities, P50) averaged over the entire 100-frame dataset. Statistical analyses evaluated E, M, and P50 correlations with CS and VFQ. Results.: Contrast sensitivity ranged from 1.19%W (normal) to 5.59%W. All QUS parameters in two scan positions within the whole-central ROI correlated with CS (R > 0.67, P < 0.001). P50 in the nasal longitudinal position had R = 0.867 (P < 0.001). Correlations with VFQ ranged from R = 0.52 (P < 0.013) to R = 0.65 (P < 0.001). Conclusions.: Quantitative ultrasound provides quantitative measures of vitreous echodensity that correlate with CS and VFQ, providing objective assessment of vitreous structure underlying the functional disturbances induced by floaters, useful to quantify vitreous disease severity and the response to therapy.

30 November 1998 in Physical Review Letters
Verified
Journal Article
Closed access
PDF file
JKJeff Ketterling
Jeff Ketterling
RARobert E. Apfel
Robert E. Apfel
Single bubble sonoluminescence stability in ambient radius ( R0), drive pressure ( Pa) phase space is examined for water partially saturated with pure argon, pure nitrogen, and argon/nitrogen mixtures in order to examine the dissociation hypothesis (DH) of Lohse and Hilgenfeldt [J. Chem. Phys. 107, 6986 (1997)]. A stroboscopic imaging system was employed to measure R0 and the maximum bubble radius Rmax. Pa was calculated by fitting the Rayleigh-Plesset equation to R0 and Rmax. Excellent agreement was seen between experiment and prediction over a wide range of parameters, validating DH.

1 December 1996 in The Journal of the Acoustical Society of America
Verified
Journal Article
Closed access
YTYuren Tian
Yuren Tian
JKJeff Ketterling
Jeff Ketterling
RARobert E. Apfel
Robert E. Apfel
A direct imaging system is introduced to study the oscillations of microbubbles acoustically levitated in water. The bubble is illuminated with a light emitting diode (LED) which is strobed at a frequency different from the driving sound field. This technique slows the moving image of the bubble, allowing one to observe the shape of a bubble oscillating between 5 to 100 μm in diameter. The bubble shapes are recorded on video tape and then analyzed by an automatic image analysis system which gives the variations of bubble diameter versus time. Experiments were performed with and without the bubbles sonoluminescing. Asymmetric shapes of the bubbles were observed in some cases.

1 July 2004 in Ultrasonic Imaging
Verified
Journal Article
Open access
PDF file
EFErnest J. Feleppa
Ernest J. Feleppa
CPChristopher R. Porter
Christopher R. Porter
JKJeff Ketterling
Jeff Ketterling
PLPaul Lee
Paul Lee
SDShreedevi Dasgupta
Shreedevi Dasgupta
AKAndrew Kalisz
Andrew Kalisz
Because current methods of imaging prostate cancer are inadequate, biopsies cannot be effectively guided and treatment cannot be effectively planned and targeted. Therefore, our research is aimed at ultrasonically characterizing cancerous prostate tissue so that we can image it more effectively and thereby provide improved means of detecting, treating and monitoring prostate cancer. We base our characterization methods on spectrum analysis of radiofrequency (rf) echo signals combined with clinical variables such as prostate-specific antigen (PSA). Tissue typing using these parameters is performed by artificial neural networks. We employed and evaluated different approaches to data partitioning into training, validation, and test sets and different neural network configuration options. In this manner, we sought to determine what neural network configuration is optimal for these data and also to assess possible bias that might exist due to correlations among different data entries among the data for a given patient. The classification efficacy of each neural network configuration and data-partitioning method was measured using relative-operating-characteristic (ROC) methods. Neural network classification based on spectral parameters combined with clinical data generally produced ROC-curve areas of 0.80 compared to curve areas of 0.64 for conventional transrectal ultrasound imaging combined with clinical data. We then used the optimal neural network configuration to generate lookup tables that translate local spectral parameter values and global clinical-variable values into pixel values in tissue-type images (TTIs). TTIs continue to show cancerous regions successfully, and may prove to be particularly useful clinically in combination with other ultrasonic and nonultrasonic methods, e.g., magnetic-resonance spectroscopy.

27 March 2006 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
JKJeff Ketterling
Jeff Ketterling
SRS. Ramachandran
S. Ramachandran
OAO. Aristizabal
O. Aristizabal
An experimental system to take advantage of the imaging capabilities of a 5-ring polyvinylidene fluoride (PVDF)-based annular array is presented. The array has a 6-mm total aperture and a 12-mm geometric focus. The experimental system is designed to pulse a single element of the array and then digitize the received data of all array channels simultaneously. All transmit/receive pairs are digitized and then the data are post-processed with a synthetic-focusing technique to achieve an enhanced depth of field (DOF). The performance of the array is experimentally tested with a wire phantom consisting of 25-mum diameter wires diagonally spaced at 1-mm by 1-mm intervals. The phantom permitted the efficacy of the synthetic-focusing algorithm to be tested and was also used for two-way beam characterization. Experimental results are compared to a spatial impulse response method beam simulation. After synthetic focusing, the two-way echo amplitude was enhanced over the range of 8 to 19 mm and the 6-dB DOF spanned from 9 to 15 mm. For a wire at a fixed axial depth, the relative time delays between transmit/receive ring pairs agreed with theoretical predictions to within plusmn2 ns. To further test the system, B-mode images of an excised bovine eye were rendered