Background: An atrioventricular defibrillator system with a floating atrial dipole (VDD ICD) can provide atrial sensing by a single lead. Our aim was to compare the arrhythmia detection efficacy of VDD ICDs with conventional single- (VVI) and dual-chamber (DDD) defibrillators. Methods: Data from consecutive patients undergoing ICD implantation were retrospectively analyzed. The primary endpoint was the incidence of device-detected, new-onset atrial arrhythmias, while secondary endpoints were sensing parameters, complication rates, incidence of appropriate/inappropriate ICD therapy, arrhythmic/heart failure-related hospitalizations, and all-cause mortality. Results: A total of 256 patients (mean age 64 ± 12 years, male 75%, primary prophylaxis 28%, mean follow-up 3.7 ± 2.4 years) were included (VVI: 93, VDD: 94, DDD: 69). Atrial arrhythmia episodes were detected more frequently by VDD systems compared to VVI ICDs (aHR 7.087; 95% CI 2.371–21.183; p < 0.001), and at a rate similar to that of DDD ICDs (aHR 1.781; 95% CI 0.737–4.301; p = 0.200). The rate of inappropriate shocks was not different among the three ICD systems. Conclusion: VDD devices revealed an advantage in atrial arrhythmia detection compared to VVI ICDs and were non-inferior to DDD systems. Their main indication may be closer monitoring in high-risk patients with atrial arrhythmias to help therapy optimization and not the improvement of tachycardia discrimination.
19 May 2026 in Indian Pacing and Electrophysiology Journal
Limited data are available on long-term changes in the conduction system following transcatheter aortic valve implantation (TAVI). To assess AV conduction changes after TAVI and examine the relationship between pacemaker-derived parameters and surface ECG findings. We retrospectively analyzed patients who underwent PM implantation after TAVI between July 2014 and June 2023. Demographic, imaging, procedural, and ECG data were collected. A dedicated follow-up (FU) visit, including device interrogation and a 12-lead ECG recorded during temporary VVI pacing at 30 bpm, was performed on average 1.7 ± 1.3 years post-implant. Based on FU ECGs, patients were classified as having persistent (persAVB) or regressive AV block (regrAVB). Among 377 TAVI procedures, 33 PM implantations (8.7%) occurred a mean of 5.7 days post-procedure. Indications included third-degree AV block in 27 (81%), second-degree AV block in 3 (9%), and bradycardia in 3 (9%). FU ECGs were available for 14 patients; 7 (50%) showed conduction recovery. Baseline QRS duration was significantly wider in persAVB than in regrAVB (107.1 ± 27.3 ms vs. 80.7 ± 1.6 ms; p = 0.038). Median right ventricular pacing (RVp) burden was substantially higher in persAVB (100% [IQR 98.8-100%]) compared with regrAVB (0% [IQR 0-2.5%]; p < 0.001). Pacemaker dependency was present in 28% of persAVB patients and in none of the regrAVB group. A substantial proportion of patients showed recovery of atrioventricular conduction over time, particularly those without pre-existing conduction disturbances. The degree of RVp closely reflected conduction recovery status during follow-up.
17 November 2025 in Journal of Cardiovascular Electrophysiology