BACKGROUND: Although minor, a sore throat after endotracheal intubation can adversely affect patient satisfaction and postoperative function. We compared the effects of 2 endotracheal tube cuff shapes on postoperative sore throat. METHODS: One hundred ninety-one adult patients were included in the study. After induction of anesthesia, patients were randomized to endotracheal intubation with a conventional cylindrical-shaped cuff (Group C, n = 95) or a tapered-shaped cuff (Group T, n = 96). The number of intubation attempts, time to achieve endotracheal intubation, and duration of intubation were recorded. Postoperative sore throat and hoarseness were assessed at 1, 6, and 24 hours after surgery. A 0- to 100-mm visual analog scale was used to evaluate sore throat severity. The primary outcome of this study was the overall cumulative incidence of postoperative sore throat in the 24-hour evaluation period in the 2 groups. RESULTS: The overall incidence of postoperative sore throat was lower in Group T than in Group C (32% vs 54%; relative risk = 0.60, 95% confidence interval: 0.43–0.85; P= .003). At 6 hours after surgery, the incidence and severity of postoperative sore throat were lower in Group T compared with Group C (Bonferroni-corrected P< .05). Postoperative hoarseness also occurred less frequently in Group T compared with Group C (19% vs 37%; P= .006). Group T had lower incidence of hoarseness at 1 and 6 hours after surgery than Group C (Bonferroni-corrected P< .05), but the incidence of hoarseness at 24 hours after surgery did not differ between groups. CONCLUSIONS: Intubation using an endotracheal tube with a tapered cuff reduced the incidence and severity of postoperative sore throat and the incidence of hoarseness after surgery when compared with an endotracheal tube with a cylindrical cuff.
In the present study, we compare the LMA-Protector™ and the i-gel™ in terms of adequacy of the airway seal, insertion time, ease and accuracy of insertion, and the incidence of postoperative sore throat. In 110 anesthetized and paralyzed adult patients, the i-gel™ (n = 55) or the LMA-Protector™ (n = 55) was inserted. The primary outcome was airway leak pressure. The secondary outcomes included the first-attempt success rate, insertion time, ease and accuracy of the device insertion, ease of gastric tube placement, blood staining on the device after removal, and incidence and severity of postoperative sore throat. The airway leak pressure was higher with the LMA-Protector™ than with the i-gel™ (31 [7] cmH2O vs. 27 [6] cmH2O, respectively; P = 0.016). Insertion time was longer with the LMA-Protector™ than with the i-gel™ (27 [16] sec vs. 19 [16] sec, respectively, P < 0.001), but ease of insertion and the first-attempt success rate were not different between the two groups. The LMA-Protector™ provided a worse fiberoptic view of the vocal cords and more difficult gastric tube insertion than the i-gel™ (both P < 0.001). Blood staining on the device was more frequent with the LMA-Protector™ than with the i-gel™ (P = 0.033). The incidence and severity of postoperative sore throat were not different between the two groups. The LMA-Protector™ provided a better airway sealing effect than the i-gel™. However, it required a longer insertion time, provided a worse fiberoptic view of the vocal cords, and caused more mucosal injury compared to the i-gel™. ClinicalTrials.gov (NCT03078517). Registered prior to patient enrollment, Date of registration: Mar 13, 2017.
21 April 2020 in Canadian Journal of Anesthesia/Journal canadien d'anesthésie
BACKGROUND: For safe nasotracheal intubation without middle turbinate injury, the tracheal tube should pass through the lower pathway, which is beneath the inferior turbinate and immediately above the nasal floor of the nostril. The purpose of this study was to assess the influence of nasal tip lifting on the incidence of passing preformed nasal Ring-Adair-Elwyn (RAE) tubes through the lower pathway during nasotracheal intubation. METHODS: Patients were randomly assigned to a “nasal tip lifting group” or a “neutral group.” For patients in the nasal tip lifting group, an investigator pulled the nasal tip in a cephalad direction when inserting a preformed nasal RAE tube into the nostril after induction of anesthesia. For patients in the neutral group, a tube was inserted with the nasal tip in a neutral position. The pathway by which the tube passed in each patient was identified using a fiberscope. The incidence of the tube passing through the lower pathway was compared between the 2 groups. The incidence of epistaxis was also evaluated. RESULTS: Eighty-six patients were enrolled and completed the study protocol. The incidence of the tracheal tube passing through the lower pathway was significantly higher in the nasal tip lifting group (79.1%) than in the neutral group (51.2%) (relative risk, 1.55; 95% confidence interval, 1.11–2.15; P = .007). Although the incidence of epistaxis was not different between the groups (18.6% vs 32.6%; P = .138), it was lower when the tracheal tube passed nasal cavity through the lower pathway (14.3%) than the upper pathway (46.7%), regardless of the randomized group with adjustment for potentially confounding variables (odds ratio, 0.19; 95% confidence interval, 0.07–0.54; P = .002). CONCLUSIONS: The nasal tip lifting maneuver helped to guide preformed nasal RAE tubes into the lower pathway during nasotracheal intubation.