Alexander Fingerle

Dr. Alexander Fingerle

orcid

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2021 in Radiology
Verified
Journal Article
Closed access
FGFlorian Gassert
Florian Gassert
TUTheresa Urban
Theresa Urban
MFManuela Frank
Manuela Frank
KWKonstantin Willer
Konstantin Willer
WNWolfgang Noichl
Wolfgang Noichl
FPFranz Pfeiffer
Franz Pfeiffer
This study introduces the qualitative and quantitative characteristics of x-ray dark-field chest radiographs in healthy humans. Background X-ray dark-field radiography takes advantage of the wave properties of x-rays, with a relatively high signal in the lungs due to the many air-tissue interfaces in the alveoli. Purpose To...

1 April 2022 in Radiology
Verified
Journal Article
Closed access
TUTheresa Urban
Theresa Urban
FGFlorian Gassert
Florian Gassert
MFManuela Frank
Manuela Frank
KWKonstantin Willer
Konstantin Willer
WNWolfgang Noichl
Wolfgang Noichl
DPDaniela Pfeiffer
Daniela Pfeiffer
Dark-field chest radiography shows dark-field signal intensity losses that correspond to emphysematous areas found on chest CT images in participants with emphysema. Background Dark-field chest radiography allows for assessment of lung alveolar structure by exploiting wave optical properties of x-rays. Purpose To evaluate the qualitative and quantitative featur...

1 February 2019 in European Journal of Radiology
Verified
Journal Article
Closed access
DDDominik Deniffel
Dominik Deniffel
ASAndreas Sauter
Andreas Sauter
JDJulia Dangelmaier
Julia Dangelmaier
AFAlexander Fingerle
Alexander Fingerle
ERErnst J. Rummeny
Ernst J. Rummeny
DPDaniela Pfeiffer
Daniela Pfeiffer

1 April 2012 in European Journal of Radiology
Verified
Journal Article
Closed access
MEMatthias Eiber
Matthias Eiber
AFAlexander Fingerle
Alexander Fingerle
MBMelanie Brügel
Melanie Brügel
JGJochen Gaa
Jochen Gaa
ERErnst J. Rummeny
Ernst J. Rummeny
KHKonstantin Holzapfel
Konstantin Holzapfel

26 May 2023 in Investigative Radiology
Verified
Journal Article
Open access
TUTheresa Msc Urban
Theresa Msc Urban
ASAndreas Sauter
Andreas Sauter
MFManuela Frank
Manuela Frank
KWKonstantin Willer
Konstantin Willer
WNWolfgang Msc Noichl
Wolfgang Msc Noichl
DPDaniela Pfeiffer
Daniela Pfeiffer
Objectives: Dark-field chest radiography (dfCXR) has recently reached clinical trials. Here we compare dfCXR to conventional radiography for the detection and staging of pulmonary emphysema. Materials and Methods: Subjects were included after a medically indicated computed tomography (CT) scan, showing either no lung impairments or different stages of emphysema. To establish a ground truth, all CT scans were assessed by 3 radiologists assigning emphysema severity scores based on the Fleischner Society classification scheme. Participants were imaged at a commercial chest radiography device and at a prototype for dfCXR, yielding both attenuation-based and dark-field images. Three radiologists blinded to CT score independently assessed images from both devices for presence and severity of emphysema (no, mild, moderate, severe). Statistical analysis included evaluation of receiver operating characteristic curves and pairwise comparison of adjacent Fleischner groups using an area under the curve (AUC)–based z test with a significance level of 0.05. Results: A total of 88 participants (54 men) with a mean age of 64 ± 12 years were included. Compared with conventional images (AUC = 0.73), readers were better able to identify emphysema with images from the dark-field prototype (AUC = 0.85, P = 0.005). Although ratings of adjacent emphysema severity groups with conventional radiographs differed only for trace and mild emphysema, ratings based on images from the dark-field prototype were different for trace and mild, mild and moderate, and moderate and confluent emphysema. Conclusions: Dark-field chest radiography is superior to conventional chest radiography for emphysema diagnosis and staging, indicating the technique's potential as a low-dose diagnostic tool for emphysema assessment.

23 September 2014 in PLOS ONE
Verified
Journal Article
Open access
PDF file
DMDaniela Muenzel
Daniela Muenzel
TKThomas Köhler
Thomas Köhler
KBKevin Brown
Kevin Brown
SŽStanislav Žabić
Stanislav Žabić
AFAlexander Fingerle
Alexander Fingerle
PNPeter B. Noël
Peter B. Noël
Evaluation of a new software tool for generation of simulated low-dose computed tomography (CT) images from an original higher dose scan. Original CT scan data (100 mAs, 80 mAs, 60 mAs, 40 mAs, 20 mAs, 10 mAs; 100 kV) of a swine were acquired (approved by the regional governmental commission for animal protection). Simulations of CT acquisition with a lower dose (simulated 10–80 mAs) were calculated using a low-dose simulation algorithm. The simulations were compared to the originals of the same dose level with regard to density values and image noise. Four radiologists assessed the realistic visual appearance of the simulated images. Image characteristics of simulated low dose scans were similar to the originals. Mean overall discrepancy of image noise and CT values was −1.2% (range −9% to 3.2%) and −0.2% (range −8.2% to 3.2%), respectively, p>0.05. Confidence intervals of discrepancies ranged between 0.9–10.2 HU (noise) and 1.9–13.4 HU (CT values), without significant differences (p>0.05). Subjective observer evaluation of image appearance showed no visually detectable difference. Simulated low dose images showed excellent agreement with the originals concerning image noise, CT density values, and subjective assessment of the visual appearance of the simulated images. An authentic low-dose simulation opens up opportunity with regard to staff education, protocol optimization and introduction of new techniques.