Sura Ahmed

Mrs. Sura Ahmed

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2023 in AIP Conference Proceedings
Verified
Conference Paper
Open access
PDF file
NANoor T. Al-Sharify
Noor T. Al-Sharify
SASura Ahmed
Sura Ahmed
HNHusam Yahya Nser
Husam Yahya Nser
OSOng Hang See
Ong Hang See
ZAZainab talib Al-sharify
Zainab talib Al-sharify
LWLeong Yeng Weng
Leong Yeng Weng
With advancements in technology, it is now possible to explore the characteristics of a cornea in depth. A computer-aided diagnostic tool known as corneal topog

8 August 2024 in Heliyon
Verified
Journal Article
Open access
NANoor T. Al-Sharify
Noor T. Al-Sharify
HNHusam Yahya Nser
Husam Yahya Nser
NGNebras Ghaeb
Nebras Ghaeb
ZAZainab talib Al-sharify
Zainab talib Al-sharify
OSOng Hang See
Ong Hang See
SASura Ahmed
Sura Ahmed
The corneal eye diseases such as Keratoconus cause weakening of the cornea, with this disease the cornea can change in shape. This condition affects between 1 in 3,000 to 1 in 10,000 people. The main reason for the development of such conditions is unknown and can have significant impacts. Over the last decade, with advancements in computerized corneal topography assessments, researchers have increasingly expressed interest in corneal topography for research as well as clinical activities. Up till now, several aspheric numerical models have been developed as well as proposed to define the complex shape of the cornea. A commonly used term for characterizing the asphericity in an eye is the Q value, a common indicator of the aspherical degree of the cornea. It is one of the critical parameters in the mathematical description model of the cornea as it represents the cornea's shape and the eye's characteristics. Due to the utmost importance of this Q value of the cornea, a couple of studies have attempted to explore this parameter and its distribution, merely in terms of its influence on the human eye's optical properties. The corneal Q value is an important factor that needs to be determined to treat for any refractive errors as corneal degeneration are disease that can lead to potential problems with the structure of the cornea. This study aims to highlight the need to understand Q value of the cornea as this can essentially assist with personalising corneal refractive surgeries and implantation of intraocular lenses. Therefore, the relevance of corneal Q value must be studied in association with different patients, especially ones who have been diagnosed with cataracts, brain tumours, or even COVID-19. To address this issue, this paper first carries out a literature review on the optics of the cornea, the relevance of corneal Q value in ophthalmic practice and studies corneal degenerations and its causes. Thereafter, a detailed review of several noteworthy relevant research studies examining the Q value of the cornea is performed. To do so, an elaborate database is created, which presents a list of different research works examined in this study and provides key evidence derived from these studies. This includes listing details on the age, gender, ethnicity of the eyes assessed, the control variables, the technology used in the study, and even more. The database also delivers important findings and conclusions noted in each study assessed. Next, this paper analyses and discusses the magnitude of corneal Q value in various scenarios and the influence of different parameters on corneal Q value. To design visual optical products as well as to enhance the understanding of the optical properties of an eye, future studies could consider the database and work presented in this study as useful references. In addition, the work can be used to make informed decisions in clinical practice for designing visual optical products as well as to enhance the understanding of the optical properties of an Eye.

1 January 2023 in AIP Conference Proceedings
Verified
Conference Paper
Open access
PDF file
HNHusam Yahya Nser
Husam Yahya Nser
NANoor T. Al-Sharify
Noor T. Al-Sharify
SASura Ahmed
Sura Ahmed
LWLeong Yeng Weng
Leong Yeng Weng
OSOng Hang See
Ong Hang See
NGNebras Ghaeb
Nebras Ghaeb
This paper aims to comprehensively review the refractive error measurement theories in human cornea, which is considered one of the most important theories used

27 November 2024 in Bioengineering
Verified
Journal Article
Open access
PDF file
NANoor T. Al-Sharify
Noor T. Al-Sharify
SYSalman Yussof
Salman Yussof
NGNebras Ghaeb
Nebras Ghaeb
ZAZainab talib Al-sharify
Zainab talib Al-sharify
HNHusam Yahya Naser
Husam Yahya Naser
LWLeong Yeng Weng
Leong Yeng Weng
This paper provides comprehensive insights into the cornea and its diseases, with a particular focus on keratoconus. This paper explores the cornea’s function in maintaining ocular health, detailing its anatomy, pathological conditions, and the latest developments in diagnostic techniques. Keratoconus is discussed extensively, covering its subtypes, etiology, clinical manifestations, and the application of the Q-value for quantification. Several diagnostic techniques, such as corneal topography, are crucial points of discussion. This paper also examines the use of machine learning models, specifically Decision Tree and Nearest Neighbor Analysis, which enhance the accuracy of diagnosing based on topographical corneal parameters from corneal topography. These models provide valuable insights into disease progression and aid in clinical decision making. Integrating these technologies in medical research opens promising avenues for enhanced disease detection. Our findings demonstrate the effectiveness of Decision Tree and Nearest Neighbor Analysis in classifying and predicting conditions based on corneal parameters. The Decision Tree achieved classification accuracy of 62% for training and 65.7% for testing, while Nearest Neighbor Analysis yielded 65.4% for training and 62.6% for holdout samples. These models offer valuable insights into the progression and severity of keratoconus, aiding clinicians in treatment and management decisions.

29 July 2025 in Iraqi Journal for Computer Science and Mathematics
Verified
Journal Article
Open access
PDF file
SASura Ahmed
Sura Ahmed
NGNebras Ghaeb
Nebras Ghaeb
SYSalman Yussof
Salman Yussof
NANoor T. Al-Sharify
Noor T. Al-Sharify
HNHusam Yahya Nser
Husam Yahya Nser
LWLeong Yeng Weng
Leong Yeng Weng
The ophthalmologist uses various techniques to diagnose corneal abnormalities, including corneal topography and tomography devices. Currently generated color corneal elevation surface maps from topographic imaging devices are essential for detecting ocular diseases, while accurately classifying these maps to differentiate between different shapes remains an issue. This study aims to assess and compare parameters of the front and back corneal surface elevation map patterns of normal/abnormal corneas. Two hundred cases were randomly taken (100 normal and 100 abnormal) with a single normal reference image, and then an additional 25 cases were added later for the optimization process. The preprocessing of all images involved converting them from color to black and white images to highlight the elevation bowtie shapes. The correlation coefficient, as implemented in MATLAB, was used to identify similar shapes of bowties for both normal and abnormal cases and determine the elevation values at the thinnest location. Additionally, it was used to measure the elevation bowtie angle between the reference normal image (case) and all other cases for image classification. Individually, the cut-off value of maximum correlation (mean ± 2 standard deviation) was calculated to distinguish between normal/abnormal patterns for 200 cases, and the cut-off values (0.974418 ≥ correlation ≥ 0.575, 0.994548 ≥ correlation ≥ 0.537841) were used for elevation back and front, respectively. Normal angle has cut-off values of (≤ 25 and =90), while normal elevation values at the thinnest location are (≤ 15, ≤ 20) for front and back surfaces. This method is based on elevation back, achieving an accuracy of 74%, and an accuracy of 64% was achieved for elevation front. Our model’s final accuracy was calculated by combining both the elevation back and elevation front final results to achieve 75.5% accuracy. Adding more data will not further increase the accuracy output since it has reached its optimal level. The development of this method aims to assist ophthalmologists in diagnosing and confirming clinical decisions through the accurate detection of corneal disease.

1 January 2023 in AIP Conference Proceedings
Verified
Conference Paper
Open access
PDF file
SASura Ahmed
Sura Ahmed
NANoor T. Al-Sharify
Noor T. Al-Sharify
HNHusam Yahya Nser
Husam Yahya Nser
ZAZainab talib Al-sharify
Zainab talib Al-sharify
NGNebras Ghaeb
Nebras Ghaeb
LWLeong Yeng Weng
Leong Yeng Weng
The anterior densely innervated corneal tissue determines more than 50% of the optical power reflection. The Cornea’s structure is composed of six layers, from the epithelium to the endothelium, and a deficiency in one of these layers produces various illnesses that result in alterations in the tissue’s physical and chemical characteristics. One of the mane problems happened to eye cornea is found during Keratoconus (KC), where the Cornea shape changes from normal aspherical to the cone-like protrusion of the central Cornea. This affected tissue suffers from decreased vision due to myopia, irregular astigmatism, and corneal scarring. A comprehensive review was done to investigate the Physical, chemical Properties and Clinical Diagnosis Modalities in the current work for patients with Keratoconu. Physically, where the Cornea is irregular in shape, incoming light rays cannot be focused on a single point, causing the wavefront’s typical spherical shape to change. In addition, the chemical structure of basal epithelial cells influences their shape and arrangement. At the same time, a break in Bowman’s layer, which is common in keratoconus, may be responsible for the conical shape of the eye. Various technologies such as keratometry, Slit lamp, Ultrasound Pachymetry, and corneal topography/tomography have been used for diagnosing KC corneas. Each of them provides essential parameters and indicates the Cornea’s state. Nowadays, corneal topography techniques allow for identifying the major morphological features of diseased tissue. Furthermore, early detection of KC is critical for avoiding ocular refractive surgery, but there are no standardized screening criteria for early diagnosis.