The artificial pancreas (AP) system is designed to regulate blood glucose in subjects with type 1 diabetes using a continuous glucose monitor informed controller that adjusts insulin infusion via an insulin pump. However, current AP developments are mainly hybrid closed-loop systems that include feed-forward actions triggered by the announcement of meals or exercise. The first step to fully closing the loop in the AP requires removing meal announcement, which is currently the most effective way to alleviate postprandial hyperglycemia due to the delay in insulin action. Here, a novel approach to meal detection in the AP is presented using a sliding window and computing the normalized cross-covariance between measured glucose and the forward difference of a disturbance term, estimated from an augmented minimal model using an Unscented Kalman Filter. Three different tunings were applied to the same meal detection algorithm: (1) a high sensitivity tuning, (2) a trade-off tuning that has a high amount of meals detected and a low amount of false positives (FP), and (3) a low FP tuning. For the three tunings sensitivities 99 ± 2%, 93 ± 5%, and 47 ± 12% were achieved, respectively. A sensitivity analysis was also performed and found that higher carbohydrate quantities and faster rates of glucose appearance result in favorable meal detection outcomes.
1 January 2017 in IEEE Reviews in Biomedical Engineering
The artificial pancreas (AP) is a closed-loop (CL) device with the potential to reduce the complications associated with type 1 diabetes mellitus (T1DM) by maintaining euglycemia in patients. The AP encompasses an algorithm that determines the amount of insulin (and other hormones) to be administered to the patient via a continuous subcutaneous insulin infusion (CSII) pump using information provided by a continuous glucose monitor (CGM) and other sensors. As the AP approaches commercialization special attention must be given to safety within all the individual components, including physiological changes in the patient, as well as, safety issues that can arise when these components are combined into a single system. Therefore, we analyzed the specific hazards applicable to the AP with the aim of exposing areas of safety that have yet to be addressed.
10 February 2019 in IEEE Journal of Biomedical and Health Informatics
The purpose of this study was to develop an algorithm that detects aerobic exercise and triggers disturbance rejection actions to prevent exercise-induced hypoglycemia. This approach can provide a solution to poor glycemic control during and after aerobic exercise, a major hindrance in the participation of exercise by patients with type 1 diabetes. This novel exercise-induced hypoglycemia reduction algorithm (EHRA) detects exercise using a threshold on a disturbance term, a parameter estimated from an augmented minimal model using an unscented Kalman filter. After detection, the EHRA triggers the following three actions: First, a carbohydrate suggestion, second, a reduction in basal insulin and the insulin-on-board maximum limit, and finally, a 30% reduction of the next insulin meal bolus. The EHRA was tested in silico using a 15-day scenario with 8 exercise sessions of 50 min at 60%VO 2max on alternating days. The EHRA was able to obtain improved results when compared to strategies with and without exercise announcement. The unannounced, announced, and EHRA strategies all obtained an overall percentage of time in range (70-180 mg/dl) of 94% and a percentage of time <; 70 mg/dl of 2%, 0%, and 0% , respectively. The EHRA was tested for robustness during exercise sessions of +25% and -25% intensity and results suggest that the EHRA is able to account for variability in exercise intensity, duration, and patient dynamics such as glucose uptake rate and insulin sensitivity.
Continuous glucose monitors (CGMs) are prone to inaccuracy due to time lags, sensor drift, calibration errors, and measurement noise. The aim of this study is to derive the model of the error of the second generation Medtronic Paradigm Veo Enlite (ENL) sensor and compare it with the Dexcom SEVEN PLUS (7P), G4 PLATINUM (G4P), and advanced G4 for Artificial Pancreas studies (G4AP) systems. An enhanced methodology to a previously employed technique was utilized to dissect the sensor error into several components. The dataset used included 37 inpatient sessions in 10 subjects with type 1 diabetes (T1D), in which CGMs were worn in parallel and blood glucose (BG) samples were analyzed every 15 ± 5 min Calibration error and sensor drift of the ENL sensor was best described by a linear relationship related to the gain and offset. The mean time lag estimated by the model is 9.4 ± 6.5 min. The overall average mean absolute relative difference (MARD) of the ENL sensor was 11.68 ± 5.07% Calibration error had the highest contribution to total error in the ENL sensor. This was also reported in the 7P, G4P, and G4AP. The model of the ENL sensor error will be useful to test the in silico performance of CGM-based applications, i.e., the artificial pancreas, employing this kind of sensor.
Preclinical testing and validation of therapeutic strategies developed for patients with type 1 diabetes (T1D) require a cohort of virtual patients (VPs). However, current simulators provide a limited number of VPs, lack real-life scenarios, and inadequately represent intra- and inter-day variability in insulin sensitivity and blood glucose (BG) profile. The generation of a realistic scenario was achieved by using the meal patterns, insulin profiles (basal and bolus), and exercise sessions estimated as disturbances using clinical data from a cohort of 14 T1D patients using the Medtronic 640G insulin pump provided by the Hospital Clínic de Barcelona. The UVa/Padova’s cohort of adult patients was used for the generation of a new cohort of VPs. Insulin model parameters were optimized and adjusted in a day-by-day fashion to replicate the clinical data to create a cohort of 75 VPs. All primary and secondary outcomes reflecting the BG profile of a T1D patient were analyzed and compared to the clinical data. The mean BG 166.3 versus 162.2 mg/dL ( = 0.19), coefficient of variation 32% versus 33% ( = 0.54), and percent of time in range (70 to 180 mg/dL) 59.6% versus 66.8% ( = 0.35) were achieved. The proposed methodology for generating a cohort of VPs is capable of mimicking the BG metrics of a real cohort of T1D patients from the Hospital Clínic de Barcelona. It can adopt the inter-day variations in the BG profile, similar to the observed clinical data, and thus provide a benchmark for preclinical testing of control techniques and therapy strategies for T1D patients.
9 February 2014 in Journal of Diabetes Science and Technology
Background: Type 1 diabetes mellitus (T1DM) complications are significantly reduced when normoglycemic levels are maintained via intensive therapy. The artificial pancreas is designed for intensive glycemic control; however, large postprandial excursions after a meal result in poor glucose regulation. Pramlintide, a synthetic analog of the hormone amylin, reduces the severity of postprandial excursions by reducing appetite, suppressing glucagon release, and slowing the rate of gastric emptying. The goal of this study is to create a glucose-insulin-pramlintide physiological model that can be employed into a controller to improve current control approaches used in the artificial pancreas. Methods: A model of subcutaneous (SC) pramlintide pharmacokinetics (PK) was developed by revising an intravenous (IV) pramlintide PK model and adapting SC insulin PK from a glucose-insulin model. Gray-box modeling and least squares optimization were used to obtain parameter estimates. Pharmacodynamics (PD) were obtained by choosing parameters most applicable to pramlintide mechanisms and then testing using a proportional PD effect using least squares optimization. Results: The model was fit and validated using 27 data sets, which included placebo, PK, and PD data. SC pramlintide PK root mean square error values range from 1.98 to 10.66 pmol/L. Pramlintide PD RMSE values range from 10.48 to 42.76 mg/dL. Conclusions: A new in silico model of the glucose-insulin-pramlintide regulatory system is presented. This model can be used as a platform to optimize dosing of both pramlintide and insulin as a combined therapy for glycemic regulation, and in the development of an artificial pancreas as the kernel for a model-based controller.