We propose a simple and robust method to detect heartbeats using the ballistocardiogram (BCG) signal that is produced by a hydraulic bed sensor placed under the mattress. The proposed method is found beneficial especially when the BCG signal does not display consistent J-peaks, which can often be the case for overnight, in-home monitoring, especially with frail seniors. Heartbeat detection is based on the short-time energy of the BCG signal. Compared with previous methods that rely on the J-peaks observed from the BCG amplitude, we are able to achieve considerable improvement even when significant distortions are present. Test results are included for different BCG waveform patterns from older adults.
6 February 2019 in IEEE Transactions on Biomedical Engineering
To develop quantitative methods for the clinical interpretation of the ballistocardiogram (BCG). A closed-loop mathematical model of the cardiovascular system is proposed to theoretically simulate the mechanisms generating the BCG signal, which is then compared with the signal acquired via accelerometry on a suspended bed. Simulated arterial pressure waveforms and ventricular functions are in good qualitative and quantitative agreement with those reported in the clinical literature. Simulated BCG signals exhibit the typical I, J, K, L, M, and N peaks and show good qualitative and quantitative agreement with experimental measurements. Simulated BCG signals associated with reduced contractility and increased stiffness of the left ventricle exhibit different changes that are characteristic of the specific pathological condition. The proposed closed-loop model captures the predominant features of BCG signals and can predict pathological changes on the basis of fundamental mechanisms in cardiovascular physiology. This paper provides a quantitative framework for the clinical interpretation of BCG signals and the optimization of BCG sensing devices. The present paper considers an average human body and can potentially be extended to include variability among individuals.
13 July 2018 in IEEE Transactions on Biomedical Engineering
We propose a non-wearable hydraulic bed sensor system that is placed underneath the mattress to estimate the relative systolic blood pressure of a subject, which only differs from the actual blood pressure by a scaling and an offset factor. Two types of features are proposed to obtain the relative blood pressure, one based on the strength and the other on the morphology of the bed sensor BCG pulses. The relative blood pressure is related to the actual by a scale and an offset factor that can be obtained through calibration. The proposed system is able to extract the relative blood pressure more accurately with a less sophisticated sensor system compared to those from the literature. We tested the system using a dataset collected from 48 subjects right after active exercises. Comparison with the ground truth obtained from the blood pressure cuff validates the promising performance of the proposed system, where the mean correlation between the estimate and the ground truth is near 90% for the strength feature and 83% for the morphology feature.
We present an approach for patient activity recognition in hospital rooms using depth data collected using a Kinect sensor. Depth sensors such as the Kinect ensure that activity segmentation is possible during day time as well as night while addressing the privacy concerns of patients. It also provides a technique to remotely monitor patients in a non-intrusive manner. An existing fall detection algorithm is currently generating fall alerts in several rooms in the University of Missouri Hospital (MUH). In this paper we describe a technique to reduce false alerts such as pillows falling off the bed or equipment movement. We do so by detecting the presence of the patient in the bed for the times when the fall alert is generated. We test our algorithm on 96 hours obtained in two hospital rooms from MUH.
The analysis and interpretation of cardiac magnetic resonance (CMR) images are often time-consuming. The automated segmentation of cardiac structures can reduce the time required for image analysis. Spatial similarities between different CMR image types were leveraged to jointly segment multiple sequences using a segmentation model termed a multi-image type UNet (MI-UNet). This model was developed from 72 exams (46% female, mean age 63 ± 11 years) performed on patients with hypertrophic cardiomyopathy. The MI-UNet for steady-state free precession (SSFP) images achieved a superior Dice similarity coefficient (DSC) of 0.92 ± 0.06 compared to 0.87 ± 0.08 for a single-image type UNet (p < 0.001). The MI-UNet for late gadolinium enhancement (LGE) images also had a superior DSC of 0.86 ± 0.11 compared to 0.78 ± 0.11 for a single-image type UNet (p = 0.001). The difference across image types was most evident for the left ventricular myocardium in SSFP images and for both the left ventricular cavity and the left ventricular myocardium in LGE images. For the right ventricle, there were no differences in DCS when comparing the MI-UNet with single-image type UNets. The joint segmentation of multiple image types increases segmentation accuracy for CMR images of the left ventricle compared to single-image models. In clinical practice, the MI-UNet model may expedite the analysis and interpretation of CMR images of multiple types.