Rochele Sogari Picoloto

Dr. Rochele Sogari Picoloto


Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 April 2016 in Journal of Analytical Atomic Spectrometry
Verified
Journal Article
Closed access
PDF file
Marcia Foster MeskoMarcia Foster Mesko
Marcia Foster Mesko
VCVanize C. Costa
Vanize C. Costa
RPRochele Sogari Picoloto
Rochele Sogari Picoloto
CBCezar Augusto Bizzi
Cezar Augusto Bizzi
Paola A. MelloPaola A. Mello
Paola A. Mello
Halogens are a group of reactive elements, which are capable of making stable bonds with metals and nonmetals. Due to their properties, they play an important biochemical role in living organisms; some, such as F, Cl and I, are essential for humans, whereas others, such as Br, are non-essential and can cause key toxicological effects. This is probably the main reason why this group of elements has been extensively studied in food and biological materials, especially in recent years. The determination of halogens at trace levels requires suitable instrumentation, and plasma-based techniques, such as inductively coupled plasma optical emission spectrometry (ICP-OES) and especially inductively coupled plasma mass spectrometry (ICP-MS), are particularly well suited for this purpose. Although they are very versatile for performing multielemental determination, halogens present high ionization potentials and low wavelength emission lines, and they are prone to interferences due to matrix effects. Such drawbacks are difficult to overcome without changing instrumental features, such as mass or optical resolution. On the other hand, some interferences due to the presence of dissolved carbon in solution, enhancement or suppression of ionization, and related matrix effects can be minimized by applying an appropriate sample preparation step. In this sense, the present review covers the main sample preparation methods applied for halogen determination in food and biological materials by using ICP-OES and ICP-MS. Methods based on dilution, solubilization, extraction or those involving matrix decomposition (e.g., acid digestion and combustion) are discussed based on key applications selected in the last 20 years.

14 June 2012 in Environmental Toxicology
Verified
Journal Article
Closed access
PDF file
MPM. T. Paula
M. T. Paula
AZA. P. Zemolin
A. P. Zemolin
AVA. P. Vargas
A. P. Vargas
RGR. M. Golombieski
R. M. Golombieski
ELE. L. S. Loreto
E. L. S. Loreto
TPThaís Posser
Thaís Posser

7 April 2010 in Analytical Methods
Verified
Journal Article
Closed access
PDF file
CBCezar Augusto Bizzi
Cezar Augusto Bizzi
Erico Marlon Moraes FloresErico Marlon Moraes Flores
Erico Marlon Moraes Flores
RPRochele Sogari Picoloto
Rochele Sogari Picoloto
JBJuliano Smanioto Barin
Juliano Smanioto Barin
JNJoaquim Araújo Nóbrega
Joaquim Araújo Nóbrega
The efficiency of diluted nitric acid solutions under oxygen pressure for decomposition of bovine liver was evaluated using microwave-assisted wet digestion. Calcium, Cu, Fe, Mg, Mn and Zn were determined by inductively coupled plasma optical emission spectrometry (ICP OES). Efficiency was evaluated by determining the residual carbon content (RCC) by ICP OES and residual acidity in digests. Samples (up to 500 mg) were digested using nitric acid solutions (0.1, 0.5, 1, 2, 3, 7, and 14 mol L−1 HNO3) and the effect of oxygen pressure was evaluated using pressures of 0.5, 1, 1.5 and 2 MPa. It was demonstrated that 2 and 0.5 mol L−1 nitric acid solutions may be used for efficient digestion of 500 and 100 mg of bovine liver, respectively, with oxygen pressures ranging from 0.5 to 2 MPa. Using these conditions, less than 0.86 and 0.21 mL of concentrated nitric acid were necessary to digest 500 and 100 mg of sample, respectively. Similar digestion efficiencies for both conditions were obtained under pressures of O2 ranging from 0.5 to 2 MPa. The residual acidities in final digests were lower than 24% when compared to the initial amount of acid used for digestion. The accuracy of the proposed procedure was evaluated using certified reference materials of bovine liver and bovine muscle. Using a solution of 2 mol L−1 with oxygen pressure of 0.5 MPa for 500 mg of sample, the agreement with certified values ranged from 96 to 105% (n = 5). Using the proposed procedure with diluted nitric acid it was possible to obtain RCC values lower than 15% that is important for minimizing the generation of laboratory residues and improving limits of detection.

16 January 2020 in Rapid Communications in Mass Spectrometry
Verified
Journal Article
Closed access
PDF file
Erico Marlon Moraes FloresErico Marlon Moraes Flores
Erico Marlon Moraes Flores
Paola A. MelloPaola A. Mello
Paola A. Mello
SKSindy R. Krzyzaniak
Sindy R. Krzyzaniak
VCVitoria H. Cauduro
Vitoria H. Cauduro
RPRochele Sogari Picoloto
Rochele Sogari Picoloto

1 September 2015 in Industrial Crops and Products
Verified
Journal Article
Closed access
CCCaroline Viegas Cavalheiro
Caroline Viegas Cavalheiro
RPRochele Sogari Picoloto
Rochele Sogari Picoloto
ACAlexandre José Cichoski
Alexandre José Cichoski
RWRoger Wagner
Roger Wagner
CMCristiano Ragagnin de Menezes
Cristiano Ragagnin de Menezes
JBJuliano Smanioto Barin
Juliano Smanioto Barin

1 April 2012 in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
Verified
Journal Article
Closed access
AMAline Lima Hermes Müller
Aline Lima Hermes Müller
RPRochele Sogari Picoloto
Rochele Sogari Picoloto
Paola A. MelloPaola A. Mello
Paola A. Mello
MFMarco F. Ferrão
Marco F. Ferrão
MSMaria de Fátima Pereira dos Santos
Maria de Fátima Pereira dos Santos
Erico Marlon Moraes FloresErico Marlon Moraes Flores
Erico Marlon Moraes Flores