Kyungtaek Jun

Dr. Kyungtaek Jun

National Institute for Mathematical Sciences

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 June 2023 in Scientific Reports
Verified
Journal Article
Open access
PDF file
KJKyungtaek Jun
Kyungtaek Jun
HLHyunju Lee
Hyunju Lee
The security of the RSA cryptosystem is based on the difficulty of factoring a large number N into prime numbers $$p$$ p and $$q$$ q satisfying $$N=p\times q$$ N = p × q . This paper presents a prime factorization method using a D-Wave quantum computer that could threaten the RSA cryptosystem in the future. The starting point for this method is very simple, representing two prime numbers as qubits. Then, we set the difference between the product of the two prime numbers expressed in qubits and N as a cost function, and we find the solution when the cost function is minimized. D-Wave's quantum annealer can find the minimum value of any quadratic problem. However, the cost function must be a higher-order unconstrained optimization (HUBO) model because it contains second- or higher-order terms. We used a hybrid solver accessible via Leap, D-Wave’s real-time quantum cloud service, and the dimod package provided by the D-Wave Ocean software development kit (SDK) to solve the HUBO problem. We also successfully factorized 102,454,763 with 26 logical qubits. In addition, we factorized 1,000,070,001,221 using the range-dependent Hamiltonian algorithm.

25 January 2017 in Scientific Reports
Verified
Journal Article
Open access
PDF file
KJKyungtaek Jun
Kyungtaek Jun
SYSeokhwan Yoon
Seokhwan Yoon
Since X-ray tomography is now widely adopted in many different areas, it becomes more crucial to find a robust routine of handling tomographic data to get better quality of reconstructions. Though there are several existing techniques, it seems helpful to have a more automated method to remove the possible errors that hinder clearer image reconstruction. Here, we proposed an alternative method and new algorithm using the sinogram and the fixed point. An advanced physical concept of Center of Attenuation (CA) was also introduced to figure out how this fixed point is applied to the reconstruction of image having errors we categorized in this article. Our technique showed a promising performance in restoring images having translation and vertical tilt errors.

1 September 2023 in Scientific Reports
Verified
Journal Article
Open access
PDF file
KJKyungtaek Jun
Kyungtaek Jun
Computed tomography (CT) has been developed as a nondestructive technique for observing minute internal images in samples. It has been difficult to obtain photorealistic (clean or clear) CT images due to various unwanted artifacts generated during the CT scanning process, along with the limitations of back-projection algorithms. Recently, an iterative optimization algorithm has been developed that uses an entire sinogram to reduce errors caused by artifacts. In this paper, we introduce a new quantum algorithm for reconstructing CT images. This algorithm can be used with any type of light source as long as the projection is defined. Assuming an experimental sinogram produced by a Radon transform, to find the CT image of this sinogram, we express the CT image as a combination of qubits. After acquiring the Radon transform of the undetermined CT image, we combine the actual sinogram and the optimized qubits. The global energy optimization value used here can determine the value of qubits through a gate model quantum computer or quantum annealer. In particular, the new algorithm can also be used for cone-beam CT image reconstruction and for medical imaging.

5 February 2024 in Results in Control and Optimization
Verified
Journal Article
Open access
KJKyungtaek Jun
Kyungtaek Jun

22 March 2023 in Results in Control and Optimization
Verified
Journal Article
Open access
KJKyungtaek Jun
Kyungtaek Jun
HLHyunju Lee
Hyunju Lee

1 July 2025 in Scientific Reports
Verified
Journal Article
Open access
PDF file
KJKyungtaek Jun
Kyungtaek Jun
HLHyunju Lee
Hyunju Lee
Computed tomography (CT) is an important imaging technique used in medical analysis of the internal structure of the human body. Previously, image segmentation methods were required after acquiring reconstructed CT images to obtain segmented CT images which made it susceptible to errors from both reconstruction and segmentation algorithms. However, this paper introduces a new approach using an advanced quantum optimization algorithm called quadratic unconstrained binary optimization (QUBO) for CT image segmentation. This algorithm allows CT image reconstruction and segmentation to be performed simultaneously. This algorithm segments CT images by minimizing the difference between a sinogram in a superposition state with qubits, obtained using the mathematical projection including the Radon transform, and the experimentally acquired sinogram from X-ray images for various angles. Furthermore, we leveraged X-ray mass attenuation coefficients to reduce the number of logical qubits required for our quantum optimization algorithm, and we employed D-Wave’s hybrid solver to solve the optimization problem. We compared the segmentation results of our algorithm with those of classical algorithms using X-ray images of actual tooth samples to validate the results of our algorithm. The comparison revealed that, after undergoing appropriate image post-processing, our algorithm’s segmentation results matched those of classical algorithms that perform segmentation after reconstruction, except for some pixels at the boundary. We expect that the new quantum optimization CT algorithm will bring about great advancements in medical imaging.