Mucoid degeneration of the anterior cruciate ligament (ACL) is a rare cause of anterior knee pain (AKP). Some case reports have been published; however, it is difficult to diagnose and is often underdiagnosed or misdiagnosed because of its pathophysiological ambiguity. We report a rare case of a patient diagnosed with bilateral mucoid degeneration of the ACL with AKP and no limited joint range of motion (ROM). A 59-year-old man with spontaneous right AKP was admitted to our hospital. He first underwent arthroscopic resection of the thickened medial plica protruding far into the medial patellofemoral joint (PFJ) but felt little effectiveness thereafter. He then had an arthroscopic release of the lateral patellar retinaculum because of valgus knee and patellar instability, which resulted in only temporary improvement. Then, the AKP relapsed, this time with limitations in the ROM. Magnetic resonance imaging (MRI0 showed a diffuse, thickened ACL with a high inhomogeneous intensity in the T2-weighted and proton density weighted images and which looked similar to a celery stalk. Based on the patients history and MRI findings, we suspected mucoid degeneration of the ACL and subsequently performed arthroscopic excision. At the same time, AKP appeared on the other side. Since the MRI demonstrated a similar celery stalk image as before, the same operation was performed on this side, as well. Finally, AKP and the limitation of the ROM were relieved approximately one month after surgery. Due to the patient only suffering from AKP with a preserved ROM, it took about 14 months to diagnose this disease. It should, therefore, always be considered in cases of AKP alone.
An 11-year-old boy was admitted to our hospital due to severe pain in his right knee when he landed after jumping over a vaulting box. A plain X-ray image and computed tomography scan showed an avulsion fracture of the lower pole of the patella and patella alta. Furthermore, magnetic resonance imaging (MRI) revealed an articular cartilage lesion and rupture between the inferior pole of the patella and the patella tendon. We diagnosed a sleeve fracture of the patella and performed surgical treatment. Open reduction and internal fixation were performed by the pull-out technique using transosseous no. 2 MaxBraid™ (Zimmer Biomet, Tokyo, Japan) sutures. While postoperative weight-bearing was permitted, the knee joint was immobilized in a brace for four weeks. Three months of postoperative assessment revealed excellent functional outcomes.
Background/Objectives: Proximal femoral fractures are particularly common in older adults, and cases requiring conversion to total hip arthroplasty may arise because of treatment failure or osteoarthritis. Fractures around the distal screw removal holes can be problematic. This study aimed to analyze the relationship between stem length and femoral stress distribution to determine the optimal stem length. Methods: A finite element analysis simulation was conducted using pre-existing femoral computed tomography data, an intramedullary nail, and three types of stems of varying lengths. Loads simulating normal walking and stair climbing were applied, and the average and maximum equivalent stresses were measured on both the medial and lateral sides of the distal screw removal hole for each stem length. Statistical analysis was then performed to evaluate the stress distributions. Results: The average stress around the distal screw removal hole tended to decrease as stem length increased. The maximum stress was significantly lower with the 160-mm stem, which provides a 40-mm bridging length, compared to the 120-mm and 130-mm stems, where the stem tip aligned with or only slightly extended past the distal screw removal hole (bridging lengths of 0 mm and 10 mm, respectively). Conclusions: In conversion hip total arthroplasty following proximal femoral fractures, using a sufficiently long stem can help avoid stress concentration around the distal screw removal hole, thereby potentially reducing the risk of periprosthetic fractures.
Background/Objectives: Stress concentration around distal screw-removal holes confers a major risk for periprosthetic fractures following conversion total hip arthroplasty (cTHA) for intertrochanteric femoral fractures. Optimal stem-selection criteria and guidelines for cTHA can improve clinical outcomes. We determined the influence of the cementless stem length on the stress distribution around distal screw-removal holes. Methods: For the finite element analysis, institutional data from preoperative CT scans of contralateral femurs of patients who underwent THA were used. To replicate the post-nail-removal state, we used 3D registration of standard triangulated language data of the intramedullary nail as an unused material to simulate distal screw-removal holes, located 135 mm from the proximal end of the intramedullary nail. Cementless stems of 130, 140, 150, and 160 mm were individually registered using STL data, and cTHA models were constructed accordingly. Using simulations under load conditions representing normal walking and stair climbing, the mean and maximum equivalent stress values around the distal screw-removal holes were calculated. For multiple comparisons, repeated-measures ANOVA with Bonferroni correction was employed. Results: Compared to the 130 mm stem, the 150 mm and 160 mm stems similarly reduced the maximum equivalent stress around the distal screw-removal holes, although the 140 mm stem showed no significant difference with other stems. Conclusions: A ≥150 mm stem length reliably mitigated stress concentration around distal screw-removal holes post-cTHA; it is the optimal choice for balancing effectiveness and risk of complications and may contribute to improved long-term clinical outcomes. This study provides practical evidence for stem selection in cTHA and offers valuable insights for future treatment guidelines.
12 July 2025 in Archives of orthopaedic and trauma surgery
Introduction: Intraoperative periprosthetic femoral fractures (IPFF) are serious complications of total hip arthroplasty (THA) that occur more frequently with cementless stems than with cemented stems. Although cerclage wiring is commonly used to stabilize IPFFs, the biomechanical effects of subsequent stem fixation methods remain unclear. This study aimed to compare the biomechanical stability of cemented and cementless stems following cerclage wire fixation in an experimental IPFF model. Materials and methods: Six fourth-generation composite femurs with simulated Vancouver A2-type fractures were stabilized using a single 1.8 mm cerclage wire. Identical stem designs of polished cemented stems and fully hydroxyapatite-coated cementless stems were implanted in three specimens of each group. After applying a vertical axial load of 2000 N, an additional 40° of internal rotation was imposed. The primary outcome was the maximum torque at the time of fracture. Secondary outcomes included the maximum internal rotation angle, construct stiffness (calculated from force-displacement curves above 1500 N), and peak strain at three positions on the cerclage wire, measured using strain gauges. Results: The maximum torque was significantly higher in the cemented group compared to the cementless group (160.8 ± 24.9 vs. 89.1 ± 18.0 N·m, p = 0.016). Although the differences in stiffness and internal rotation angle were not statistically significant, both trended higher in the cemented group. The peak strain was consistently lower in the cemented group, with a significant difference at the medial side of the fracture line ( p = 0.011, Cohen’s d = − 3.64). Conclusions: Cemented stems demonstrated superior biomechanical stability following cerclage wire fixation in the IPFF model, likely because of improved stress distribution via the cement mantle. Therefore, cemented fixation may be a favorable option for managing IPFF during THA.
Background/Objectives: Preoperative muscle atrophy leads to persistent gait abnormalities in patients undergoing total hip arthroplasty (THA). Efficient motor learning of the gluteus medius is crucial for their recovery. In this study, a single-joint hybrid assistive limb (HAL) was developed to assist hip abduction. We aimed to evaluate the muscle activity and safety of this device during hip abduction in healthy adults. Methods: Ten healthy adults (five males and five females; mean age, 40.7 years) with no hip disorders performed one set of 30 repetitions of side-lying hip abduction under three conditions: without HAL (pre-HAL), with HAL, and without HAL (post-HAL). Muscle activities of the gluteus medius, gluteus maximus, tensor fasciae latae, rectus femoris, and biceps femoris (expressed as percentage of maximum voluntary contraction [%MVC]); vital signs; hip visual analog scale (VAS); and hip abduction and flexion angles were assessed. The mean values were compared among the conditions. Results: The %MVC of the gluteus medius significantly increased from 52% (pre-HAL) to 75.4% (HAL) and then decreased slightly to 61.6% (post-HAL). No other muscle groups showed significant changes. Vital signs and hip VAS scores showed no significant variation. Although no significant differences were found in the hip abduction and flexion angles, a reduction in the hip flexion angle was observed in the HAL and post-HAL conditions. Conclusions: The hip abduction HAL effectively and safely enhanced gluteus medius activity. Reduction in the hip flexion angle during HAL and post-HAL suggests the possibility of appropriate abduction movements and motor learning effects.