TOMOFUMI NISHINO

Dr. TOMOFUMI NISHINO

University of Tsukuba, Faculty of Medicine
orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 September 2021 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
YNYusuke Nishida
Yusuke Nishida
TOMOFUMI NISHINOTOMOFUMI NISHINO
TOMOFUMI NISHINO
KTKenta Tanaka
Kenta Tanaka
SOShinzo Onishi
Shinzo Onishi
AKAkihiro Kanamori
Akihiro Kanamori
Masashi YamazakiMasashi Yamazaki
Masashi Yamazaki
Ultrasonography and MRI are used for imaging evaluation of patellar tendinopathy, and “thickening of the tendon” is known as one of the characteristic findings. However, there are no evidence-based quantitative criteria to help evaluate this phenomenon. The purpose of this study was to investigate an objective measure of patellar tendon thickness. Patellar tendon thickness was evaluated in 65 elite university athletes using both ultrasonography and MRI. The relationship between tendon thickness and clinical patellar tendinopathy was investigated, and the cutoff value of the tendon thickness was calculated. Of the 129 knees included in the analysis, clinical patellar tendinopathy was found in 16 knees (12.4%). The proximal patellar tendon was significantly thicker in athletes with clinical patellar tendinopathy on both ultrasonography (8.3 mm vs. 5.1 mm; p < 0.001) and MRI (9.9 mm vs. 5.5 mm; p < 0.001). Setting the cutoff value to a thickness of >7.0 mm was an accurate predictor of clinical patellar tendinopathy (ultrasonography: sensitivity 81.3%, specificity 95.6%; MRI: sensitivity 100%, specificity 89.4%). Both ultrasonography and MRI measurement of the proximal patellar tendon thickness reflected the presence of clinical patellar tendinopathy. Defining “thickening of the patellar tendon” as thicker than 7.0 mm on both ultrasonography and MRI therefore has clinical significance.

1 September 2017 in Journal of Orthopaedic Surgery
Verified
Journal Article
Open access
YSYukiyo Shimizu
Yukiyo Shimizu
HKHiroshi KAMADA
Hiroshi KAMADA
MSMasataka Sakane
Masataka Sakane
SAShizu Aikawa
Shizu Aikawa
HMHirotaka Mutsuzaki
Hirotaka Mutsuzaki
Masashi YamazakiMasashi Yamazaki
Masashi Yamazaki
Purpose: Venous thromboembolism prophylaxis is crucial. To facilitate active ankle movement in postoperative and bedridden patients, we developed a novel leg exercise apparatus (LEX). We investigated the effect of the LEX by comparing increases in lower extremity venous flow during different modes of exercise using the LEX. Methods: In eight healthy participants, we measured venous flow volume and velocity in the femoral vein using duplex ultrasonography at 1, 10, 20, and 30 min after completing three modes of 1-min LEX exercises. The exercises involved (1) rapid single motion (ankle dorsi–plantar flexion; 60 cycles/min); (2) slow single motion (30 cycles/min); and (3) slow combined leg motion. Results: Flow volumes after modes 1, 2, and 3 were 1.63-, 1.39-, and 1.53-fold above baseline at 30 min, respectively. Short periods of rapid single motion, with the LEX, improved postexercise lower extremity venous flow volumes at 30 min and mean venous flow velocity at 20 min, compared to slow single motion exercise. Even at slow speeds, combined-motion improved flow volume compared to single motion. Conclusion: Short periods of rapid single motion exercise, with the LEX, improved postexercise venous flow volumes in the lower extremities at 30 min and mean venous flow velocity at 20 min. These effects were greater than those produced by slow single motion exercises. However, even at slow speeds, combined-motion exercises improved flow volume compared to single motion. Therefore, LEX may prove effective at preventing thromboembolism in postoperative and bedridden patients.

1 July 2010 in The Journal of Bone and Joint Surgery. British volume
Verified
Journal Article
Open access
TOMOFUMI NISHINOTOMOFUMI NISHINO
TOMOFUMI NISHINO
FCFei Chang
Fei Chang
TIT. Ishii
T. Ishii
TYT. Yanai
T. Yanai
HMHajime Mishima
Hajime Mishima
NON. Ochiai
N. Ochiai
We have previously shown that joint distraction and movement with a hinged external fixation device for 12 weeks was useful for repairing a large articular cartilage defect in a rabbit model. We have now investigated the results after six months and one year. The device was applied to 16 rabbits who underwent resection of the articular cartilage and subchondral bone from the entire tibial plateau. In group A (nine rabbits) the device was applied for six months. In group B (seven rabbits) it was in place for six months, after which it was removed and the animals were allowed to move freely for an additional six months. The cartilage remained sound in all rabbits. The areas of type II collagen-positive staining and repaired soft tissue were larger in group B than in group A. These findings provide evidence of long-term persistence of repaired cartilage with this technique and that weight-bearing has a positive effect on the quality of the cartilage.

18 December 2021 in Asia-Pacific Journal of Sports Medicine, Arthroscopy, Rehabilitation and Technology
Verified
Journal Article
Open access
TOMOFUMI NISHINOTOMOFUMI NISHINO
TOMOFUMI NISHINO
KOKazuhiro Obara
Kazuhiro Obara
YNYusuke Nishida
Yusuke Nishida
HYHiroshi Yamaguchi
Hiroshi Yamaguchi
MHMitsutoshi Hayashi
Mitsutoshi Hayashi
Masashi YamazakiMasashi Yamazaki
Masashi Yamazaki
To verify whether a large-scale international volleyball competition could be conducted safely using the bubble method, both for our participating team and as a whole. All 32 men’s and women’s teams were gathered in one place and a large-scale international volleyball competition was held for over a month without spectators using the bubble method. More than 1,000 people participated in the event, and 572 volleyball players played a total of 248 matches during the competition. There were 54 participants from Japan, including 27 male and female staff and players each. There was one team doctor for both men and women. A total of 2,250 PCR tests and 7,920 antigen tests were performed over 38 days. We investigated the incidence of infection in our team and in all participating teams. There were 9 fever cases from our men’s team, but all of them tested negative for COVID-19. Overall, a total of 10,170 tests were performed and only one was positive. In order to ensure the health and well-being of all participants, the indoor competition was concluded safely without the occurrence of COIVD-19 clusters in the bubble system with strict adherence to various strict protocols of COVID-19.

4 November 2009 in Journal of Orthopaedic Research
Verified
Journal Article
Open access
PDF file
TOMOFUMI NISHINOTOMOFUMI NISHINO
TOMOFUMI NISHINO
TITomoo Ishii
Tomoo Ishii
FCFei Chang
Fei Chang
TYTakaji Yanai
Takaji Yanai
AWArata Watanabe
Arata Watanabe
NONaoyuki Ochiai
Naoyuki Ochiai
The purpose of this study was to clarify the effect of gradual weight bearing (GWB) on regenerating cartilage. We developed a novel external fixation device (EFD) with a controllable weight‐bearing system and continuous passive motion (CPM). A full‐thickness defect was created by resection of the entire articular surface of the tibial plateau after the EFD was fixed in the rabbit's left knee. In the GWB group (n = 6), GWB was started 6 weeks after surgery. In the CPM group (n = 6), CPM with EFD was applied in the same manner without GWB. The control group (n = 5) received only joint distraction. All rabbits were sacrificed 9 weeks after surgery. The central one‐third of the regenerated tissue was assessed and scored blindly using a grading scale modified from the International Cartilage Repair Society visual histological assessment scale. The areas stained by Safranin‐O and type II collagen antibody were measured, and the percentage of each area was calculated. There was no significant difference in the histological assessment scale among the groups. The percentage of the type II collagen‐positive area was significantly larger in the GWB group than in the CPM group. The present study suggests that optimal mechanical stress, such as GWB, may affect regeneration of cartilage, in vivo. © 2009 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 28:600–606, 2010

1 May 2016 in Journal of Orthopaedic Science
Verified
Journal Article
Closed access
HKHaruo Kawamura
Haruo Kawamura
HMHajime Mishima
Hajime Mishima
HSHisashi Sugaya
Hisashi Sugaya
TOMOFUMI NISHINOTOMOFUMI NISHINO
TOMOFUMI NISHINO
YSYukiyo Shimizu
Yukiyo Shimizu
SMShumpei Miyakawa
Shumpei Miyakawa