Attill Saemann

Dr. Attill Saemann


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 November 2024 in Acta Neurochirurgica
Verified
Journal Article
Open access
PDF file
EWEmilia Westarp
Emilia Westarp
ASAttill Saemann
Attill Saemann
MZMarek Zelechovski
Marek Zelechovski
BFBalazs Faludi
Balazs Faludi
PCPhilippe Cattin
Philippe Cattin
RGRaphael Guzman
Raphael Guzman
Purpose: With the growing demand for shared decision-making and patient-centered care, optimal informed consent (IC) has gained relevance. Virtual reality (VR) has seen significant technological advancements, and its medical applications currently include surgical planning and medical education. This pilot study investigates the feasibility of VR-enhanced informed consent (VR-IC) in neurosurgery to improve preoperative IC and patient satisfaction. Methods: We included patients aged 18 to 75 years who were scheduled for skull base meningioma or brain aneurysm surgery between May and December 2023. Exclusion criteria were visual/auditory impairments and severe cognitive/psychiatric disorders. Patients received standard IC followed by VR-IC using patient-specific VR models of their pathology. After an initial demonstration by the surgeon, the patients used the VR station independently. A questionnaire with 18 questions on a 5-point Likert scale assessed the subjective impression of VR-IC. Results: Ten patients participated in the study, with six (60%) undergoing aneurysm clipping and four (40%) undergoing skull base meningioma resection. The mean age of the participants was 58 years (± 15, range 27 to 75 years), with four female patients (40%). Patients overall rated the VR-informed consent (VR-IC) positively with a mean of 4.22 (± 0.84). There was a better understanding of their pathology (mean 4.30 ± 0.92) and the planned procedure (mean 3.95 ± 1.04). Trust in the surgeon was rated with a mean of 3.47 (± 0.94). Only minimal side effects from the VR experience including dizziness or discomfort were noted (mean 4.60 ± 0.22). None of the participants dropped out of the study. Conclusion: VR-enhanced informed consent is feasible and improves patient understanding and satisfaction without significant side effects. These findings will guide the planning of a randomized controlled trial to validate the benefits of VR-IC in neurosurgery further.

4 September 2024 in Frontiers in Surgery
Verified
Journal Article
Open access
PDF file
ASAttill Saemann
Attill Saemann
SSSina Schmid
Sina Schmid
MLMaria Licci
Maria Licci
MZMarek Zelechowski
Marek Zelechowski
BFBalazs Faludi
Balazs Faludi
RGRaphael Guzman
Raphael Guzman
Background: Craniosynostosis is a type of skull deformity caused by premature ossification of cranial sutures in children. Given its variability and anatomical complexity, three-dimensional visualization is crucial for effective teaching and understanding. We developed a VR database with 3D models to depict these deformities and evaluated its impact on teaching efficiency, motivation, and memorability.Methods: We included all craniosynostosis cases with preoperative CT imaging treated at our institution from 2012 to 2022. Preoperative CT scans were imported into SpectoVR using a transfer function to visualize bony structures. Measurements, sub-segmentation, and anatomical teaching were performed in a fully immersive 3D VR experience using a headset. Teaching sessions were conducted in group settings where students and medical personnel explored and discussed the 3D models together, guided by a host. Participants’ experiences were evaluated with a questionnaire assessing understanding, memorization, and motivation on a scale from 1 (poor) to 5 (outstanding).Results: The questionnaire showed high satisfaction scores (mean 4.49 ± 0.25). Participants (n = 17) found the VR models comprehensible and navigable (mean 4.47 ± 0.62), with intuitive operation (mean 4.35 ± 0.79). Understanding pathology (mean 4.29 ± 0.77) and surgical procedures (mean 4.63 ± 0.5) was very satisfactory. The models improved anatomical visualization (mean 4.71 ± 0.47) and teaching effectiveness (mean 4.76 ± 0.56), with participants reporting enhanced comprehension and memorization, leading to an efficient learning process.Conclusion: Establishing a 3D VR database for teaching craniosynostosis shows advantages in understanding and memorization and increases motivation for the study process, thereby allowing for more efficient learning. Future applications in patient consent and teaching in other medical areas should be explored.

5 November 2024 in Frontiers in Surgery
Verified
Journal Article
Open access
PDF file
ASAttill Saemann
Attill Saemann
ARAdriana De Rosa
Adriana De Rosa
JOJokin Zubizarreta Oteiza
Jokin Zubizarreta Oteiza
Neha SharmaNeha Sharma
Neha Sharma
Florian Markus ThieringerFlorian Markus Thieringer
Florian Markus Thieringer
RGRaphael Guzman
Raphael Guzman
Objective: The objective of this study was to develop and evaluate a low-cost 3D-printed simulator to improve the ability of neurosurgical residents to handle and coordinate endoscopes in performing technically demanding procedures such as neuroendoscopic removal of ventricular tumors or endoscopic third ventriculostomy (ETV).Methods: The simulator was developed, printed in-house, and evaluated in a trial involving neurosurgery residents who performed ETV and intraventricular tumor resection tasks using it. Participants completed a questionnaire that assessed various aspects of the simulator's effectiveness, including anatomical visualization, procedural understanding, competency enhancement, and subjective impressions.Results: A total of 12 participants were included in the evaluation. The majority (n = 7, 53.85%) were male, with a mean age of 29.8 ± 3.27 years and 4 ± 2 years of neurosurgical experience. All participants agreed or strongly agreed (4.5 ± 0.50) that the 3D printed simulator helped develop systematic intraventricular visualization and understanding of surgical steps (4.42 ± 0.64). The handling of the endoscope was rated as realistic (4.5 ± 0.50), while the haptic qualities of the tumor were rated lower (3.83 ± 0.80; 3.92 ± 0.64). Training increased competence (4.25 ± 0.45) and coordination skills (4.5 ± 0.50), with 75% (n = 9) feeling more confident with neuroendoscopic instruments and 91.7% (n = 11) in future procedures.Conclusion: The developed 3D-printed simulator offers an accessible and practical training resource for neurosurgical residents, addressing the limitations of traditional training methods. The simulator appears to improve procedural skills and the competence of future neurosurgeons, potentially improving patient safety and outcomes in neurosurgical practice.

26 September 2024 in Brain Sciences
Verified
Journal Article
Open access
PDF file
ASAttill Saemann
Attill Saemann
DWDaniel de Wilde
Daniel de Wilde
JRJonathan Rychen
Jonathan Rychen
Michel RoethlisbergerMichel Roethlisberger
Michel Roethlisberger
MŻMarek Żelechowski
Marek Żelechowski
Raphael GuzmanRaphael Guzman
Raphael Guzman
Background/Objectives: Detailed morphometric analysis of an aneurysm and the related vascular bifurcation are critical factors when determining rupture risk and planning treatment for unruptured intracranial aneurysms (UIAs). The standard visualization of digital subtraction angiography (DSA) and its 3D reconstruction on a 2D monitor provide precise measurements but are subject to variability based on the rater. Visualization using virtual (VR) and augmented reality platforms can overcome those limitations. It is, however, unclear whether accurate measurements of the aneurysm and adjacent arterial branches can be obtained on VR models. This study aimed to assess interrater reliability and compare measurements between 3D VR, standard 2D DSA, and 3D DSA reconstructions, evaluating the reliability and accuracy of 3D VR as a measurement tool. Methods: A pool of five neurosurgeons performed three individual analyses on each of the ten UIA cases, measuring them in completely immersed 3D VR and the standard on-screen format (2D DSA and 3D reconstruction). This resulted in three independent measurements per modality for each case. Interrater reliability of measurements and morphology characterization, comparative differences, measurement duration, and VR user experience were assessed. Results: Interrater reliability for 3D VR measurements was significantly higher than for 3D DSA measurements (3D VR mean intraclass correlation coefficient [ICC]: 0.69 ± 0.22 vs. 3D DSA mean ICC: 0.36 ± 0.37, p = 0.042). No significant difference was observed between 3D VR and 2D DSA (3D VR mean ICC: 0.69 ± 0.22 vs. 2D DSA mean ICC: 0.43 ± 0.31, p = 0.12). A linear mixed-effects model showed no effect of 3D VR and 3D DSA (95% CI = −0.26–0.28, p = 0.96) or 3D VR and 2D DSA (95% CI = −0.02–0.53, p = 0.066) on absolute measurements of the aneurysm in the anteroposterior, mediolateral, and craniocaudal dimensions. Conclusions: 3D VR technology allows for reproducible, accurate, and reliable measurements comparable to measurements performed on a 2D screen. It may also potentially improve precision for measurements of non-planar aneurysm dimensions.

6 November 2025 in World Neurosurgery
Verified
Journal Article
Open access
ASAttill Saemann
Attill Saemann
DWD. de Wilde
D. de Wilde
RGR. Guzman
R. Guzman
JSJ. Soleman
J. Soleman
LGL. Greuter
L. Greuter
Innovative technologies such as augmented reality (AR) and virtual reality (VR) are increasingly utilized for teaching, training, and surgical planning in neurosurgery. This systematic review provides an overview of the literature on the application of AR and VR specifically in open neurovascular surgery. Following PRISMA 2020, PubMed and Embase were searched from January 2000 to July 2024. Eligible designs included case series with ≥5 patients, cohort studies, and randomized controlled trials evaluating AR or VR for open neurovascular procedures (aneurysms, arteriovenous malformations, revascularization/bypass, and microvascular decompression). Given substantial heterogeneity in outcomes and methods, we performed a narrative synthesis without meta-analysis. Of the 422 screened articles, 43 met inclusion. In all, 32 studies (74%) evaluated VR, 10 (23%) evaluated AR, and 1 (2%) evaluated both. Most involved aneurysm surgery (65%, n = 28), followed by AVMs (21%, n = 9), revascularization (16%, n = 7), and MVD (14%, n = 6). The most frequent application was surgical planning (67%, n = 29), followed by training/education (35%, n = 15), intraoperative use (23%, n = 10), and analysis/diagnostics (9%, n = 4). Where quantitative outcomes were reported, improvements most commonly involved planning accuracy, task efficiency (e.g., clip/operative time), and user-rated usefulness; patient-level outcomes were infrequently reported and variably defined. AR and VR are promising adjuncts for teaching, training, and planning in open neurovascular surgery, with the most consistent signals in aneurysm planning. However, evidence remains heterogeneous and largely based on surrogate or subjective measures. Comparative studies using standardized clinical endpoints are necessary to define the routine clinical impact and support broader implementation in clinical practice.

1 December 2025 in Brain Hemorrhages
Verified
Journal Article
Open access
SWStefan Wanderer
Stefan Wanderer
ASAttill Saemann
Attill Saemann
JHJoshua Haegler
Joshua Haegler
Basil Erwin GrüterBasil Erwin Grüter
Basil Erwin Grüter
JMJulian Louis Muff
Julian Louis Muff
LALukas Andereggen
Lukas Andereggen