Matheos Giakoumi

Mr. Matheos Giakoumi

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 August 2025 in Energy Conversion and Management
Verified
Journal Article
Closed access
CKCharalampos Konstantinou
Charalampos Konstantinou
MGMatheos Giakoumi
Matheos Giakoumi
NANicos Costa Angastiniotis
Nicos Costa Angastiniotis
PPPanos Papanastasiou
Panos Papanastasiou

21 December 2023 in Geomechanics for Energy and the Environment
Verified
Journal Article
Closed access
MGMatheos Giakoumi
Matheos Giakoumi
CKCharalampos Konstantinou
Charalampos Konstantinou
CEChristine Ehlig-Economides
Christine Ehlig-Economides
Panos PapanastasiouPanos Papanastasiou
Panos Papanastasiou

3 August 2024 in Gas Science and Engineering
Verified
Journal Article
Closed access
MGMatheos Giakoumi
Matheos Giakoumi
CKCharalampos Konstantinou
Charalampos Konstantinou
NPNikolas Papadimitriou
Nikolas Papadimitriou
CPConstantinos F. Panagiotou
Constantinos F. Panagiotou
ATAntonis Tsangarides
Antonis Tsangarides
PPPanos Papanastasiou
Panos Papanastasiou

25 March 2024 in ACS Biomaterials Science & Engineering
Verified
Journal Article
Open access
MGMatheos Giakoumi
Matheos Giakoumi
Pavlos S. StephanouPavlos S. Stephanou
Pavlos S. Stephanou
DKDespoina Kokkinidou
Despoina Kokkinidou
CPChara Papastefanou
Chara Papastefanou
AAAndreas Anayiotos
Andreas Anayiotos
KKKonstantinos Kapnisis
Konstantinos Kapnisis
In vitro testing methods offer valuable insights into the corrosion vulnerability of metal implants and enable prompt comparison between devices. However, they fall short in predicting the extent of leaching and the biodistribution of implant byproducts under in vivo conditions. Physiologically based toxicokinetic (PBTK) models are capable of quantitatively establishing such correlations and therefore provide a powerful tool in advancing nonclinical methods to test medical implants and assess patient exposure to implant debris. In this study, we present a multicompartment PBTK model and a simulation engine for toxicological risk assessment of vascular stents. The mathematical model consists of a detailed set of constitutive equations that describe the transfer of nickel ions from the device to peri-implant tissue and circulation and the nickel mass exchange between blood and the various tissues/organs and excreta. Model parameterization was performed using (1) in-house-produced data from immersion testing to compute the device-specific diffusion parameters and (2) full-scale animal in situ implantation studies to extract the mammalian-specific biokinetic functions that characterize the time-dependent biodistribution of the released ions. The PBTK model was put to the test using a simulation engine to estimate the concentration-time profiles, along with confidence intervals through probabilistic Monte Carlo, of nickel ions leaching from the implanted devices and determine if permissible exposure limits are exceeded. The model-derived output demonstrated prognostic conformity with reported experimental data, indicating that it may provide the basis for the broader use of modeling and simulation tools to guide the optimal design of implantable devices in compliance with exposure limits and other regulatory requirements.

6 December 2025 in Process Safety and Environmental Protection
Verified
Journal Article
Closed access
CKCharalampos Konstantinou
Charalampos Konstantinou
MGMatheos Giakoumi
Matheos Giakoumi
PPPanos Papanastasiou
Panos Papanastasiou

Verified
Journal Article
Open access
PDF file
MGMatheos Giakoumi
Matheos Giakoumi
KKKonstantinos Kapnisis
Konstantinos Kapnisis
AAAndreas Anayiotos
Andreas Anayiotos
Pavlos S. StephanouPavlos S. Stephanou
Pavlos S. Stephanou
Toxicokinetic or pharmacokinetic models, physiologically based or not, offer a unique avenue to understand the transport of toxins or pharmaceuticals in living organisms. The availability of analytical solutions to such models offers the means to engage in a plethora of applications. In the present work, we provide the framework to solve analytically such models using the matrix exponential, and we then apply this method to derive an explicit solution to four-to-five-compartment physiologically based toxicokinetic (PBTK) models considering a single- and an infinite-exponential expression for the amount of mass released from an implantable device. We also offer the conditions that need to be met for analytical solutions to be obtained when the kinetic rates are time-dependent functions. Our analysis compares the computation time between analytical and numerical solutions and characterizes the dependency of the maximum substance mass value and the time it occurs in the various tissue compartments from the material surface diffusion characteristics. Our analytical solutions, which have several advantages over the solutions obtained using numerical solvers, can be incorporated into in silico tools and provide valuable information for human health risk assessment.