Objectives: Ultrasound (US) has been reported to be a reliable imaging modality for locating the tip of peripherally inserted central venous catheters (PICC) in neonates. However, its use requires a certain level of expertise, which may limit its application. Standardization of US examinations using designed protocols may improve their efficiency and ease of use. The objective of our study is to evaluate the effectiveness of introducing a standardized US protocol for PICC guidance. Methods: An expert panel was formed in order to develop a standardized US protocol for PICC assessment. Institutional review board agreement was obtained. This protocol was then used by participating clinicians to assess PICC position. Every assessment was followed by a radiographic control. The study group consisted of 262 US examinations of PICC lines in a level III neonatal intensive care unit (NICU) performed according to the designed protocol. Subsequent statistical analysis was made with the RStudio software, R version 4.3.1 (2023-06-16 ucrt). Results: Compared to the X-ray control, standardized US examinations showed 100% sensitivity, 81% specificity, an accuracy of 98% and a 98% precision for assessing catheter placement. The Cohen’s Kappa value for the comparison of X-ray and US studies was 0.88, indicating good agreement between the two methods. Conclusions: Standardized US examinations have shown similar potential for evaluating the location of PICC lines when compared with radiographic studies. Implementing a standardized protocol in the NICU may facilitate the ultrasound assessment of PICC lines and reduce exposure to ionizing radiation.
Background: Persistent structural changes of the lungs in anorexia nervosa (AN) patients are rarely described in contemporary medical literature. The objective of our paper is to report a rare case of severe bronchiectasis and inflammatory changes to the lungs resulting from chronic malnutrition in a AN patient. Case presentation: We describe a patient with severe inflammatory lung disease caused by malnutrition, resulting in persistent bronchiectasis accompanying AN. We performed an analysis of the patient’s medical records including radiological findings and laboratory results. A review of available literature shows very little data available on this topic. Conclusion: Bronchiectasis and other structural changes of the lungs are rare, but severe complications of severe, chronic malnutrition. As exemplified by our case report, they may require extensive differential diagnosis and pose a significant clinical challenge due to their non-reversible character. A successful treatment relies heavily on the patient’s compliance and may be hard to achieve. Clinicians managing patients with anorexia nervosa should be wary of early respiratory tract dysfunction-related symptoms and always consider malnutrition bronchiectasis as a differential diagnosis option.
Objective: To assess the feasibility of implementing a simple point-of-care lung ultrasound (POC-LUS) evaluation and reporting protocol in a neonatal intensive care unit (NICU) and its effect on patient management. Study design: Retrospective observational study of POC-LUS examinations performed in a level III NICU. Each examination was performed according to a standardized protocol. An independent radiologist-assessed chest X-ray (CXR) was used to compare the POC-LUS diagnosis. The impact on patient management was also evaluated. Result: A total of 206 POC-LUS studies in 158 neonates were reviewed. There was significant agreement between POC-LUS and CXR diagnoses (84,95%, 95% CI 80,07-89,83%). POC-LUS affected patient management in 87.8% of the cases (95% CI 83,33-92,28%). Conclusion: Implementation of a simplified, sign-based protocol for POC-LUS in the NICU is feasible. POC-LUS is not inferior to CXR studies and supports patient management as an imaging modality.