Compliant foil gas seal is one of the advanced cylindrical gas seal technologies and can be commonly used in the secondary flow system of an aero-engine. It can enhance the dynamic stability of the aero-engine by meeting the steady requirements of the aero-engine seal system. To evaluate the performance of compliant foil gas seal, the steady performance of the gas seal is firstly analyzed to predict the sealing efficiency and obtain the pressure distribution of the gas seal in the compressible flow field. Then, the effects of the operating parameters on the rotordynamic coefficients are analyzed using the finite differential method. It can be used to predict the operation performance of the aero-engine and prepare for the optimization and test rig of compliant foil gas seal on the T-shaped groove.
A brush seal is a type of contact sealing technology that generates a great amount of heat during operations. The heat can affect the seal’s performance and lifespan. To study the brush seals’ temperature distribution, a new model considering the anisotropic heat transfer effect is established in this paper. The friction heat effect at the bristles’ tip is studied. The temperature field and leakage rates are obtained by using combined finite element analysis (FEA)-computational fluid dynamics (CFD) analysis and the anisotropic heat transfer theory. The influence of operating and structural parameters on the temperature field and the sealing properties of the brush seal are investigated. It is shown that the value of the rotation rate and the interference can cause the temperature of the brush seal to increase. The pressure difference enhances the convective heat transfer from the brush seals. While the temperature at the bristles’ tip increases, the radial average temperature of the bristles decreases significantly. In the case of a small pressure difference, the fence’s height can increase the windward area, leading to stiff bristles and resulting in a temperature increase at the bristles’ tip; however, the effective flow area increases, resulting in an acceleration of the radial temperature’s decrease. To summarize, the porous medium model of anisotropic heat transfer provides a new method for studying brush seals, and it can reflect the temperature distribution and leakage performance of brush seals.
To effectively address the issue of premature failure caused by the unbalanced distribution of pressure drops between the stages of a traditional two-stage finger seal, this study proposes a method to improve the pressure drop balance by increasing the protection height of the second stage back plate. We established a new numerical calculation model for a two-stage finger seal, based on the porous media model. After verifying the precision of the model, we conducted a numerical analysis to examine the impact of the protection height of the second stage back plate on the flow and heat transfer characteristics of the two-stage finger seal. We then conducted a differentiated structural design for each stage of the two-stage finger seal. The research results are as follows: the pressure drop at the second stage of the traditional two-stage finger seal exceeds that of the first stage; when the protection height of the second stage back plate of the traditional two-stage finger seal is increased from 1.5 mm to 1.57 mm, forming a two-stage pressure equalizing finger seal structure, the pressure drop between the two stages is balanced, but the leakage is greater than that of the traditional two-stage finger seal; a grate seal structure was arranged between the first and second stages of the two-stage pressure equalizing finger seal to form a two-stage pressure equalizing finger seal with grate teeth, which exhibits significantly lower leakage compared to the two-stage pressure equalizing finger seal. However, the proportion of pressure drop at the first and second stages of the two-stage pressure equalizing finger seal is 36.8% and 42.1%, respectively, while the grate tooth stage accounts for 21.1%, resulting in an imbalanced pressure drop once again. Increasing the protection height of the second stage back plate in the two-stage pressure equalizing finger seal with grate teeth to 1.6 mm results in a 37.5% pressure drop at the first and second stages, and a 25% pressure drop at the grate tooth stage. The two-stage finger seal balances the pressure drop and matches the leakage of the traditional two-stage finger seal. The maximum temperatures of the first and second stages of the finger seal are 0.7% lower and 2.6% higher compared to the traditional two-stage finger seal. This suggests that a differential multi-stage finger seal is the optimal structure.
As an advanced flexible dynamic sealing technology, the leakage characteristics of a finger seal (FS) is one of the key research areas in this technology field. Based on the fractal theory, this paper establishes a mathematical model of the FS main leakage rate considering the fractal wear effect by taking into account the influence of the wear height on the basis of the eccentric annular gap flow equation. Based on the Hagen-Poiseuille law and the fractal geometry theory of porous media, a mathematical model of the FS side leakage rate considering the fractal porous media seepage effect is developed. Then, a mathematical model of the FS total leakage rate is established. The results show that the mathematical model of the FS total leakage rate is verified with the test results, the maximum error rate is less than 5%, and the mathematical model of the FS total leakage rate is feasible. With the gradual increase in working conditions and eccentricity, the FS main leakage rate gradually increases. In addition, the effects of the fractal dimension, fractal roughness parameters and porosity after loading on the FS main leakage rate are negligible. As the fractal dimension of tortuosity after loading gradually decreases, the fractal dimension of porosity after loading gradually increases, and the FS side leakage rate gradually increases. As the porosity after loading gradually increases, the FS side leakage rate gradually increases. Under different working conditions, different fractal characteristic parameters and different porosities after loading, the weight of the FS main leakage rate is much greater than that of the FS side leakage rate by more than 95%.