Valerii Savin

Mr. Valerii Savin

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 October 2024 in Buildings
Verified
Journal Article
Open access
PDF file
KMKhrystyna Myroniuk
Khrystyna Myroniuk
YFYurii Furdas
Yurii Furdas
VZVasyl Zhelykh
Vasyl Zhelykh
Mariusz AdamskiMariusz Adamski
Mariusz Adamski
OGOlena Gumen
Olena Gumen
SMStergios-Aristoteles Mitoulis
Stergios-Aristoteles Mitoulis
The article explores passive systems for regulating microclimates in residential settings, with a focus on modular constructions. It investigates the use of the trombe wall system for passive ventilation to ensure comfort and hygiene. The study examines building designs that enable effective air circulation without using mechanical systems. Furthermore, the effectiveness of the passive system of using solar energy with the trombe wall as a ventilation device in modular houses has been experimentally confirmed. Although the research confirms the effectiveness of this solar system in modular homes, there is limited documentation regarding its overall efficiency, particularly concerning the impact of the surface pressure coefficient on ventilation. The study establishes the correlations governing the thermosiphon collector’s effectiveness at varying air layer thicknesses. Optimal parameters, such as maximum air consumption (L = 120 m3h−1), are identified at an air layer thickness (δ) of 100 mm and outlet openings area (F) of 0.056 m2. These findings pave the way for improving passive systems aimed at maintaining optimal thermal and air conditions in modern homes. The findings suggest the potential for more efficient and sustainable housing solutions. Further research is essential to understand how factors like building design and wind speed affect ventilation system efficacy.

14 July 2026 in Building and Environment
Verified
Journal Article
Open access
KMKhrystyna Myroniuk
Khrystyna Myroniuk
VSValerii Savin
Valerii Savin
VZVasyl Zhelykh
Vasyl Zhelykh
YFYurii Furdas
Yurii Furdas
MJMike Jesson
Mike Jesson
SMStergios-Aristoteles Mitoulis
Stergios-Aristoteles Mitoulis

29 December 2023 in Ventilation, Illumination and Heat Gas Supply
Verified
Journal Article
Open access
PDF file
VSValerii Savin
Valerii Savin
VZVasyl Zhelykh
Vasyl Zhelykh
Natural ventilation plays an important role in ensuring comfortable living conditions. Wind catchers are part of this process and can provide the required ventilation rate for buildings. The performance of wind catchers depends on the relevant parameters, such as height, configuration, cross-sectional shape, number of inlets, speed of movement and variability of air movement direction. HVAC equipment is not only responsible for the largest portion of the total energy consumption within a building, but also for most indoor air quality problems. Vents, air ducts, and dirty filters are a suitable place for the growth of fungi and molds produced by organic dust, which contaminate the circulating air and cause significant pollution problems. This could be more critical given that we spend almost 90% of our time indoors during our lives and work. Improvements in ventilation and air conditioning systems therefore play an important role in increasing energy efficiency in buildings, providing a better indoor climate for occupants and, as a result, reducing the likelihood of health problems. The cooling process plays an important role in creating comfortable conditions for humans. One of the most well-known elements of a passive cooling system for buildings with no or minimal energy consumption is a wind catcher. The effective-ness of wind catchers is influenced by wind force and buoyancy, and knowledge of the size, shape, and position of the outlet will help to understand new ideas and technologies for their application in modern architecture. A well-known example of natural ventilation that improves indoor quality by reducing pollution and humidity by replacing stale air with fresh outside air is a wind catcher (or wind tower). Nowadays, wind catchers are widely used in the world, having advantages in densely populated urban areas and in areas with low wind speeds, significantly affecting the reduction of cooling loads and providing the required ventilation rate of buildings. At present, there are many types of wind traps that can be classified according to the number of inlets, cross-sectional shape, and number of levels. The number of internal partitions, as well as the size and location of the openings of the wind collector, significantly affect its ventilation characteristics, efficiency, air flow velocity and turbulence, and also divide the cross-section of the wind collector into smaller channels, increasing the strength of its structure and reducing sensitivity to different wind directions

28 March 2026 in Science and Transport Progress
Verified
Journal Article
Open access
PDF file
PKP. S. Kirichenko
P. S. Kirichenko
VSValerii Savin
Valerii Savin
VKV. A. Kozachyna
V. A. Kozachyna
PMP. B. Mashykhina
P. B. Mashykhina
VKV. V. Kozachyna
V. V. Kozachyna
Purpose. Research to determine the optimal, from a technical and economic point of view, option for replacing pumping equipment using the example of the second-lift pumping station VNS–45, operated in the city of Kryvyi Rih. Methodology. The study was implemented in several stages: analysis of the actual operating mode of the station, comparison of technical characteristics of alternative pumps, construction of graphs of the combined operation of pumps with the system, statistical processing of results and assessment of practical value. This approach allowed to ensure the complexity of the analysis and reliability of the conclusions. The work used methods of hydraulic calculation, graphic modeling and analysis of the passport characteristics of pumps. All parameters were analyzed at an average daily water flow of 83.07 m3/h. The results of the study showed that the most effective are the Grundfos NB 65–200/198 and MVAe.65–200 A.1100 pumps, which provide a reduction in average monthly electricity consumption by more than 30% compared to the existing unit of the D320–50 type. Findings. The issues of excessive energy consumption by centralized water supply system facilities have been resolved. A significant part of the costs of utility companies is the operation of pumping equipment, which in most cases is technically outdated and operates outside the optimal operating mode and is energy inefficient. The results obtained can become the basis for further research in the direction of implementing automatic control systems based on variable pump rotation speeds and optimization algorithms. Originality. A scientifically based approach has been developed to modernize pumping equipment units, which in most cases are technically outdated and operate outside their optimal operating range, in order to increase energy efficiency. Practical value. The practical value of the research lies in the creation of a universal engineering model for the selection of pumping equipment for urban water supply systems, which does not require changing the hydraulic scheme or implementing complex control algorithms. The model can be applied to similar facilities without additional capital investments in engineering (pipeline) infrastructure.

1 January 2026 in Energy Engineering and Control Systems
Verified
Journal Article
Closed access
VSValerii Savin
Valerii Savin
AYAlona Yalova
Alona Yalova
NBNatalia Bondar
Natalia Bondar
DHDmytro Harasym
Dmytro Harasym
VZVasyl Zhelykh
Vasyl Zhelykh
This paper analyzes the causes of emergency damage to a building’s internal engineering systems resulting from water freezing. It has been established that a combination of climatic conditions during the cold season, design decisions and operational factors creates an increased risk of failures in water supply, heating and drainage systems. The physical conditions for water freezing in pipelines and their impact on the reliability and durability of building engineering systems are examined. To quantitatively assess the consequences of a heating system shutdown, an algorithm is proposed for determining the time required for a room to cool down, depending on the outdoor air temperature, heating system parameters and the thermal condition of the building envelope. Using the example of a typical apartment in a five-story prefabricated residential building, a calculation was performed to determine the time required for the indoor air temperature to drop to characteristic temperature levels. Additionally, an assessment was performed of the time parameters for cooling and subsequent freezing of water in heating devices after the heating system stops operating. The results obtained allow for an assessment of the potential risk of water freezing in the internal engineering systems of buildings and can be used to justify engineering solutions aimed at improving their operational reliability.

22 May 2026 in Collection of Scientific Publications NUS
Verified
Journal Article
Closed access
AYAlona M. Yalova
Alona M. Yalova
NBNataliia V. Bondar
Nataliia V. Bondar
VSValerii Savin
Valerii Savin
RSRoman V. Starovoyt
Roman V. Starovoyt