Fatemeh Hatam

Dr. Fatemeh Hatam


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 February 2024 in Journal of Environmental Management
Verified
Journal Article
Closed access
FAFaezeh Absalan
Faezeh Absalan
FHFatemeh Hatam
Fatemeh Hatam
MPMichele Prevost
Michele Prevost
Benoit BarbeauBenoit Barbeau
Benoit Barbeau
FBFrançoise Bichai
Françoise Bichai

23 March 2023 in Science of The Total Environment
Verified
Journal Article
Closed access
FHFatemeh Hatam
Fatemeh Hatam
MBMirjam Blokker
Mirjam Blokker
EDEvelyne Doré
Evelyne Doré
MPMichèle Prévost
Michèle Prévost

15 November 2022 in Water
Verified
Journal Article
Open access
PDF file
FAFaezeh Absalan
Faezeh Absalan
FHFatemeh Hatam
Fatemeh Hatam
Benoit BarbeauBenoit Barbeau
Benoit Barbeau
MPMichele Prevost
Michele Prevost
FBFrançoise Bichai
Françoise Bichai
Predicting free chlorine residual and Trihalomethanes (THMs) in water distribution systems (DS) is challenging, given the variability and imprecise description of the chlorination conditions prevailing in full-scale systems. In this work, we used the variable reaction rate constant (VRRC) model, which offers the advantage of describing variable applied dosage and rechlorination conditions without the need for model recalibration. The VRRC model successfully predicted chlorine decay and THMs formation in ammonia-containing water at the lab scale. Comparing the goodness of fit results showed a better fit by the VRRC model than the 1st-order and an equally good fit compared to the parallel 1st-order model. However, the independence of the VRRC coefficients upon chlorine dosage made it a better choice for full-scale implementation than the parallel 1st-order model. Chlorine and THMs predictions in the DS were performed in 22 locations from a full-scale DS in southern Quebec (Canada). Chlorine predictions by VRRC were conducted in the spring and fall of 2021 under changing water quality conditions (temperature, DOC, dosage). With a prediction target of 0.1 mg/L absolute error, the VRRC model met this target in 77% of the points in the spring and 73% in the fall. While the predictions were comparable and slightly better than those of the 1st-order model, the main advantage of the VRRC was its applicability under variable dosage and rechlorination conditions (e.g., booster chlorination). THMs predictions in the DS were successfully performed in fall 2021. While 91% of the nodes had less than 5 μg/L of absolute prediction error with the VRRC model, the 1st-order model only met this target in 1 out of 22 points. In addition to its high precision, the VRRC can predict THMs using only the lab scale experiments for model parametrization. This enables small utilities with limited resources to predict the possibility of THMs non-compliances under changing water quality conditions with simple lab-based experiments. Changing climatic conditions can deteriorate drinking water quality, raise regulatory concerns for chlorine and THMs, and threaten public health. Water utilities can use the simple approach proposed in this work to assess the possibility of non-compliance under changing conditions. Moreover, the efficiency of different interventions or mitigation strategies to resolve or avoid non-compliance can be evaluated with this approach.

18 September 2021 in Water
Verified
Journal Article
Open access
PDF file
FHFatemeh Hatam
Fatemeh Hatam
GEGabrielle Ebacher
Gabrielle Ebacher
MPMichele Prevost
Michele Prevost
Demand variations over time affect the hydraulic and water quality behavior of water distribution systems. Therefore, it is important to assess the network performance under various future water demand scenarios to plan effectively for demand management strategies, considering the network’s topology, volume, and operational conditions. The performance of a full-scale water distribution system is evaluated by means of hydraulic and water quality simulations under different hypothetical demand management strategies. Residential and nonresidential consumptions are varied, resulting in different global multiplicative factors (from 0.53 to 1.18). Criteria including water loss, velocity, water age, free chlorine, and THMs are selected to compare the performance of the network between the current scenario and eight demand scenarios. Water conservation generally increases nodal water age values more in smaller diameter pipes. A nodal chlorine residual reliability index is proposed to account for the duration of low chlorine residuals. With a goal of maintaining a reference free chlorine concentration of ≥0.2 mg/L, the reliability index is less than 0.9 for about 14% of nodes under the reference scenario and this proportion increases to 34% of nodes under the most extreme future water conservation scenario. The robustness of the studied network under different water conservation scenarios is tested by increasing the chlorine residual at the outlet of the WTPs from 1 to 2 mg/L. This is an easily implemented adjustment and dramatically improves the chlorine reliability (<0.9 at only 15% of the nodes), even for the most extreme future water conservation scenario. However, this reliability comes at the cost of higher yet compliant THM concentrations for the low demand scenarios, revealing the challenges of balancing competing water quality goals. With a goal of maintaining a reference level of THMs at ≤80 ug/L, the THM reliability index is ≥0.9 at almost all nodes even under the most extreme conservation scenario. The evaluation of self-cleaning potential velocities shows that sufficient velocities can only be reached at daily maximum flow in 5% of smaller diameter piping even in the reference scenario.

27 August 2025 in Sensors
Verified
Journal Article
Open access
PDF file
LPLudovica Palma
Ludovica Palma
FHFatemeh Hatam
Fatemeh Hatam
Armando Di NardoArmando Di Nardo
Armando Di Nardo
MPMichele Prevost
Michele Prevost
Water distribution networks (WDNs) are critical infrastructure yet vulnerable to contamination, thereby threatening public health. Rapid contaminant detection through sensor systems is essential for water safety. This study compares topological and optimization-based methods for sensor placement under intentional and accidental contamination scenarios triggered by low-pressure events. A novel approach is introduced to model pipe break events that generate low-pressure zones, creating pathways for contamination. Unlike traditional models, this method dynamically estimates contaminant intrusion volume based on the available node pressure. The study reveals that while optimization-based sensor placement yields better outcomes than the topological approach, the performance gap narrows as the number of sensors increases or when the system is tested against scenarios different from those used for optimization. The findings highlight a major issue in sensor detection when water quality is considered. For E. coli contamination in a chlorinated system, two conclusions emerge: rapid inactivation of E. coli makes it an unreliable indicator, even with optimized sensors, and sensor type and detection thresholds significantly affect performance, requiring careful assessment before implementation. This study provides a framework for evaluating sensor systems in WDNs, emphasizing tailored strategies that consider hydraulic conditions and water quality dynamics to improve contamination detection and public safety.

10 September 2024 in Engineering Proceedings
Verified
Conference Paper
Open access
PDF file
LPLudovica Palma
Ludovica Palma
Armando Di NardoArmando Di Nardo
Armando Di Nardo
FHFatemeh Hatam
Fatemeh Hatam
GSGiovanni Franesco Santonastaso
Giovanni Franesco Santonastaso
MPMichele Prevost
Michele Prevost
Water-distribution networks (WDNs) are vital infrastructure that are exposed to the risk of contamination. Several factors contribute to this risk, including insufficient pressure, contamination in water storage tanks and more. Sensor systems are crucial for detecting contaminations promptly. Traditional optimization methods to define sensor locations often require resource-intensive network modeling, posing challenges for water utilities. This study applies a topological approach using betweenness centrality to address sensor placement. Various weights based on the physical structure of the network are tested. Results highlight the effectiveness of weighted topological approaches in minimizing contamination’s public health impact, with the advantage of low computational costs inherent in graph-based network representations.