Ángel  Lizana

Ángel Lizana

orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 October 2008 in Optics Express
Verified
Journal Article
Closed access
PDF file
ÁLÁngel Lizana
Ángel Lizana
IMIgnacio Moreno
Ignacio Moreno
AMANDRES MARQUEZ
ANDRES MARQUEZ
CIC. Iemmi
C. Iemmi
Elena FernandezElena Fernandez
Elena Fernandez
MYM. J. Yzuel
M. J. Yzuel
In this paper we provide evidence of the temporal fluctuations of the phase modulation property of a liquid crystal on silicon (LCoS) display, and we analyze its effect when the device is used for displaying a diffractive optical element. We use a commercial twisted nematic LCoS display configured to produce a phase-only modulation, and we provide time resolved measurements of the diffraction efficiency that show rapid fluctuations of the phase modulation, in the millisecond order. We analyze how these fluctuations have to be considered in two typical methods for the characterization of the phase modulation: two beam interference and diffraction from a binary grating. We finally provide experimental results on the use of this device for displaying a computer generated hologram. A reduction of the modulation diffraction efficiency results from the phase modulation fluctuation.

27 April 2010 in Optics Express
Verified
Journal Article
Open access
PDF file
APAlba Peinado
Alba Peinado
ÁLÁngel Lizana
Ángel Lizana
JVJosep Vidal
Josep Vidal
CIClaudio Iemmi
Claudio Iemmi
JCJuan Campos
Juan Campos
In this paper we present the analysis, optimization and implementation of several Stokes polarimeter configurations based on a set-up including two variable retarders. The polarimeter analysis is based on the Mueller-Stokes formalism, and as a consequence, it is suitable to deal with depolarized light. Complete Stokes polarimeters are optimized by minimizing the amplification of simulated errors into the final solution. Different indicators useful to achieve this aim, as the condition number or the equally weighted variance, are compared in this paper. Moreover, some of the optimized polarimeters are experimentally implemented and it is studied the influence of small deviations from the theoretical ones on the amplification of the Stokes component error. In addition, the benefit of using incomplete polarimeters, when detecting specific ranges of states of polarization, is discussed.

24 January 2008 in Optics Express
Verified
Journal Article
Closed access
PDF file
AMANDRES MARQUEZ
ANDRES MARQUEZ
IMIgnacio Moreno
Ignacio Moreno
CIC. Iemmi
C. Iemmi
ÁLÁngel Lizana
Ángel Lizana
JCJuan Campos
Juan Campos
MYM. J. Yzuel
M. J. Yzuel
Optics InfoBase is the Optical Society's online library for flagship journals, partnered and copublished journals, and recent proceedings from OSA conferences.

9 October 2013 in Optics Letters
Verified
Journal Article
Closed access
PDF file
APAlba Peinado
Alba Peinado
ATAlex Turpin
Alex Turpin
ÁLÁngel Lizana
Ángel Lizana
EFEstefania Fernández
Estefania Fernández
JMJordi Mompart
Jordi Mompart
JCJuan Campos
Juan Campos
A method for polarization metrology based on the conical refraction (CR) phenomenon, occurring in biaxial crystals, is reported. CR transforms an input Gaussian beam into a light ring whose intensity distribution is linked to the incoming polarization. We present the design of a division-of-amplitude complete polarimeter composed of two biaxial crystals, whose measurement principle is based on the CR phenomenon. This design corresponds to a static polarimeter, that is, without mechanical movements or electrical signal addressing. Only one division-of-amplitude device is required, besides the two biaxial crystals, to completely characterize any state of polarization, including partially polarized and unpolarized states. In addition, a mathematical model describing the system is included. Experimental images of the intensity distribution related to different input polarization states are provided. These intensity patterns are compared with simulated values, proving the potential of polarimeters based on biaxial crystals.

5 May 2009 in Optics Express
Verified
Journal Article
Closed access
PDF file
ÁLÁngel Lizana
Ángel Lizana
NMN. Martín
N. Martín
MEM. Estapé
M. Estapé
Elena FernandezElena Fernandez
Elena Fernandez
IMIgnacio Moreno
Ignacio Moreno
MYM. J. Yzuel
M. J. Yzuel
In this paper we experimentally analyze the performance of a twisted nematic liquid crystal on silicon (LCoS) display as a function of the angle of incidence of the incoming beam. These are reflective displays that can be configured to produce amplitude or phase modulation by properly aligning external polarization elements. But we demonstrate that the incident angle plays an important role in the selection of the polarization configuration. We performed a Mueller matrix polarimetric analysis of the display that demonstrates that the recently reported depolarization effect observed in this type of displays is also dependant on the incident angle.

24 February 2015 in Optics Express
Verified
Journal Article
Closed access
PDF file
ATA. Turpin
A. Turpin
YLYu. V. Loiko
Yu. V. Loiko
APA. Peinado
A. Peinado
ÁLÁngel Lizana
Ángel Lizana
TKT. K. Kalkandjiev
T. K. Kalkandjiev
JMJ. Mompart
J. Mompart
Optics InfoBase is the Optical Society's online library for flagship journals, partnered and copublished journals, and recent proceedings from OSA conferences.