Yutaro Kuwahara

Dr. Yutaro Kuwahara


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2022 in Bone & Joint Open
Verified
Journal Article
Open access
YKYutaro Kuwahara
Yutaro Kuwahara
YTYasuhiko Takegami
Yasuhiko Takegami
KTKatsuhiro Tokutake
Katsuhiro Tokutake
YYYotaro Yamada
Yotaro Yamada
KKKentaro Komaki
Kentaro Komaki
SIShiro Imagama
Shiro Imagama
Aims: Postoperative malalignment of the femur is one of the main complications in distal femur fractures. Few papers have investigated the impact of intraoperative malalignment on postoperative function and bone healing outcomes. The aim of this study was to investigate how intraoperative fracture malalignment affects postoperative bone healing and functional outcomes. Methods: In total, 140 patients were retrospectively identified from data obtained from a database of hospitals participating in a trauma research group. We divided them into two groups according to coronal plane malalignment of more than 5°: 108 had satisfactory fracture alignment (< 5°, group S), and 32 had unsatisfactory alignment (> 5°, group U). Patient characteristics and injury-related factors were recorded. We compared the rates of nonunion, implant failure, and reoperation as healing outcomes and Knee Society Score (KSS) at three, six, and 12 months as functional outcomes. We also performed a sub-analysis to assess the effect of fracture malalignment by plates and nails on postoperative outcomes. Results: The rates of nonunion and reoperation in group U were worse than those in group S (25.0% vs 14.3%; 15.6% vs 5.6%), but the differences were not significant (p = 0.180 and p = 0.126, respectively). Mean KSS in group U at all follow-up periods was significantly worse that in group S (75.7 (SD 18.8) vs 86.0 (SD 8.7); p < 0.001; 78.9 (SD 17.2) vs 89.1 (SD 9.8); p < 0.001; 85.0 (SD 11.9) vs 91.1 (SD 7.2); p = 0.002, respectively). In the sub-analysis of plates, mean KSS was significantly worse in group U at three and six months. In the sub-analysis of nails, the rate of reoperation was significantly higher in group U (28.6% vs 5.8%; p = 0.025), and mean KSS at six and 12 months was significantly worse in Group U. Conclusion: To obtain good postoperative functional results, intraoperative alignment of the coronal plane should be accurately restored to less than 5°. Cite this article: Bone Jt Open 2022;3(2):165–172.

10 October 2024 in Medicina
Verified
Journal Article
Open access
PDF file
YKYutaro Kuwahara
Yutaro Kuwahara
GTGenta Takemoto
Genta Takemoto
SMSo Mitsuya
So Mitsuya
KYKen-Ichi Yamauchi
Ken-Ichi Yamauchi
Background and Objectives: Cerclage cable fixation with 2 mm multiple-braided cables for displaced acetabular fractures has shown good midterm functional and radiographic outcomes. We retrospectively evaluated the clinical and radiographic outcomes of cerclage cable fixations over ten years. Materials and Methods: We extracted data for patients who underwent cerclage cable fixation for acetabular fractures at a single institution from 2007 to 2012. We adopted this procedure for acetabulum fractures with posterior column fractures. Postoperative reduction quality, complications, reoperations, and Japanese Orthopedic Association (JOA) hip objective functional scores were analyzed. Postoperative reduction quality was classified using plain radiography and computed tomography. Results: We evaluated nine patients with a mean follow-up period of 14.1 ± 2.6 years (range: 10.8–18.1 years). The mean age was 47.1 ± 15.5 years old (range: 28–74 years); the mean injury severity score was 13.6 ± 4.7 (range: 9–22). The most frequent type of fracture was a both-column fracture. Anatomical reduction quality was achieved in five cases. Four patients had hip osteoarthritis at the last follow-up; among them, one patient had worsening hip arthritis > 5 years after surgery, and one patient developed osteoarthritis > 10 years after surgery. Their postoperative reduction quality was worse than their anatomical reduction quality, and both engaged in physical labor. None of the patients underwent revision total hip arthroplasty. The mean JOA hip score was 90.9 ± 7.9 (range: 74–100); seven patients scored >90 at the last follow-up. Conclusions: Cerclage cable fixation showed satisfactory postoperative reductions and favorable long-term clinical outcomes. Long-term follow-up might be necessary for patients whose postoperative reduction is not anatomical to detect late occurrence of hip osteoarthritis, even if osteoarthritis is not evident during short-term follow-up periods.

15 July 2025 in BMC Musculoskeletal Disorders
Verified
Journal Article
Open access
PDF file
YKYutaro Kuwahara
Yutaro Kuwahara
GTGenta Takemoto
Genta Takemoto
HFHiroshi Fukuoka
Hiroshi Fukuoka
SMSo Mitsuya
So Mitsuya
KYKen-Ichi Yamauchi
Ken-Ichi Yamauchi
Unstable trochanteric fractures (AO types A2 or A3) are reported to be risk factors for mechanical failure such as screw cut-out. This study aimed to compare the incidence of implant related complications and functional outcomes between cement augmentation and non-augmentation. Patients at a single institution aged > 60 years who underwent fixation using the trochanteric femoral nail advanced system (TFNA) with or without cement augmentation from 2020 to 2023 were retrospectively analyzed. We evaluated reduction quality and screw position on immediate postoperative radiographs, the occurrence of screw cut-out, and Parker’s mobility score (PMS) as functional outcomes. We evaluated 140 patients in the non-augmentation group and 93 patients in the augmentation group. The mean follow-up period was 13.6 ± 5.7 months. The mean age was 86.0 ± 8.1 years in the non-augmentation and 85.2 ± 8.3 years in the cement augmentation group. Patient demographics, including fracture type, were similar in both groups. The screw cut-out rate was seven out of 140 patients (5.0%) in the non-augmentation group, whereas no patients in the augmentation group experienced screw cut-out, and the difference was significant (p = 0.044). All cases which occurred screw cut-out were associated with postoperative poor reduction quality and screw malposition. The mean PMS at the last follow-up was 4.0 ± 3.0 in the non-augmentation group and 4.7 ± 2.7 in the augmentation group, and the difference was not significant (p = 0.187). Cement augmentation showed a significant lower screw cut-out rate compared with non-augmentation. This technique could be a more favorable option for osteoporotic unstable trochanteric fractures.

22 April 2024 in Journal of Plastic, Reconstructive & Aesthetic Surgery
Verified
Journal Article
Closed access
YKYutaro Kuwahara
Yutaro Kuwahara
THTatsuya Hara
Tatsuya Hara
TKToshikazu Kurahashi
Toshikazu Kurahashi
TKTomoyasu Kitami
Tomoyasu Kitami
MTMasahiro Tatebe
Masahiro Tatebe

28 November 2022 in Arthroplasty Today
Verified
Journal Article
Open access
YKYutaro Kuwahara
Yutaro Kuwahara
KYKen-Ichi Yamauchi
Ken-Ichi Yamauchi
SMSo Mitsuya
So Mitsuya
STShinsuke Takeda
Shinsuke Takeda
Osteoporotic acetabular fractures in elderly patients have recently been increasing, but the best treatment remains uncertain due to the difficulty in stabilizing these fractures with osteosynthesis. We performed total hip arthroplasty with an impacted bone graft on the acetabula of 3 elderly patients with comminuted acetabular fractures after confirming acetabular callus formation via radiographic imaging 2 months following the patients’ initial injuries. Two of the patients presented in the subacute phase after conservative treatment, and 1 patient had no history of trauma or quadrilateral surface destruction. Two patients achieved good functional results at the 3-year follow-up. Furthermore, no loosening of the prosthesis components or subsidence of the acetabular cemented cup was evident on radiographic imaging in any of the patients.