Gas chromatography/resonance-enhanced multiphoton ionization/time-of-flight mass spectrometry (GC/REMPI-TOFMS) using an ultraviolet nanosecond laser was employed in the trace analysis of polycyclic aromatic hydrocarbons (PAHs). A standard sample that contained 16 PAHs on the priority list of the Environmental Protection Agency of the United States of America (U.S. EPA) was measured. A sample of river water that had been pretreated by means of solid-phase extraction was analyzed by GC/MS based on electron impact ionization (EI) and REMPI to evaluate the performance of the analytical instrument. The results suggested that REMPI is superior to EI for soft ionization, and suppresses the background signal due to aliphatic hydrocarbons. Thus, GC/REMPI-TOFMS is a more reliable method for the determination of PAHs present in the environment.
The creaming behavior of a turbid oil-in-water emulsion was observed via the processes of multiphoton ionization time-of-flight mass spectrometry (MPI-TOFMS) and ultraviolet–visible spectrophotometry (UV–vis), and the results were compared. The transmittance measurement by UV–vis showed that the turbidity of the toluene emulsion was decreased with time. However, non-negligible errors are common in the measurement of a sample with high turbidity. The online measurement by MPI-TOFMS detected many spikes in the time profile, which revealed the existence of toluene droplets in the emulsion. A smooth time profile suggested that the signal intensity had initially increased, and then decreased with time; the initial concentration of toluene was 3 g/L, which had decreased by half after 60 min. The signal behavior obtained using MPI-TOFMS differed only slightly from that obtained using UV–vis. Since a change in turbidity is not the same as a change in the local concentration of an oil component, MPI-TOFMS is useful for the analysis of a turbid emulsion and offers additional information concerning the creaming phenomenon of an emulsion.
Mono-, di- and trichlorophenols were measured using resonance-enhanced multiphoton ionization mass spectrometry (MPI-MS) combined with supersonic jet (SSJ) or effusive molecular beam (EMB) spectrometry. All mono- and dichlorophenols, except 2,6-dichlorophenol, provided sharp and structured MPI spectra for the S 1 ←S 0 transition. Selectivity and sensitivity were both enhanced when SSJ spectrometry was used, compared with EMB spectrometry, because of a narrower linewidth in the MPI spectrum, given by molecular cooling by supersonic jet expansion. The ionization efficiency decreased with increasing number of chlorine substituents for the chlorophenols, since they have shorter excited-state lifetimes and require three photons for ionization. Some of the chlorophenols, which are toxic themselves, have the potential for use as indicators for analysis of polychlorinated dibenzo- p-dioxin/dibenzofurans in flue gases emitted from an incinerator.