Uwayemi Sofowote

Dr. Uwayemi Sofowote


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2021 in Science of The Total Environment
Verified
Journal Article
Closed access
USUwayemi Sofowote
Uwayemi Sofowote
RHR.M. Healy
R.M. Healy
YSY. Su
Y. Su
JDJ. Debosz
J. Debosz
MNM. Noble
M. Noble
PHP.K. Hopke
P.K. Hopke

17 May 2018 in Atmosphere
Verified
Journal Article
Open access
PDF file
Yushan SuYushan Su
Yushan Su
USUwayemi Sofowote
Uwayemi Sofowote
JDJerzy Debosz
Jerzy Debosz
LWLuc White
Luc White
AMAnthony Munoz
Anthony Munoz
Continuous monitoring of fine particulate matter (PM2.5) is important to provide near-real-time air quality information for public health protection, especially when ambient levels are elevated. The Tapered Element Oscillating Microbalance (TEOM), operated at 30 °C with a sample equilibration system (SES), was used to measure PM2.5 hourly concentrations from 2002 to 2012 in Ontario, Canada. In January 2013, the Federal Equivalent Method (FEM) Synchronized Hybrid Ambient Real-time Particulate (SHARP) model 5030 monitors replaced the TEOM devices at all monitoring stations across the province to improve measurements in cold months. Continuous PM2.5 measurements from 2013 to 2016 showed good reliability of the SHARP 5030 with an average 98% valid hourly data reported to the public. Collocated measurements indicated that 24 h averages of the SHARP 5030 were comparable to those by the filter-based integrated samplers including the Federal Reference Method (FRM), and the FEM dichotomous (Dichot) and Speciation samplers. The slope and intercept of the linear regression between the SHARP 5030 and the FRM results generally met the acceptance limits for PM2.5 Class III FEM designation, and the ratio of FEM/FRM was 1.0 or 1.1. Twenty-four-hour averages of the SHARP 5030 also correlated well with the collocated 24 h Dichot and Speciation results. The difference percentages between SHARP 5030 and 24 h integrated results were found to be larger at low rather than at high PM2.5 levels, but not dependent on seasons. Absolute differences ranged from 0 to 16 µg/m3 and root mean square differences ranged from 2.0 to 2.3 µg/m3 when the SHARP 5030 was compared with the FRM, Dichot, and Speciation samplers. A simplified approach was further developed to correct historical TEOM data for cold months to continue long-term trend analyses based on collocated measurements at eight stations where PM2.5 emission sources varied.

20 October 2022 in Atmosphere
Verified
Journal Article
Open access
PDF file
RHRobert Healy
Robert Healy
USUwayemi Sofowote
Uwayemi Sofowote
JWJonathan M Wang
Jonathan M Wang
QCQingfeng Chen
Qingfeng Chen
ATAaron Todd
Aaron Todd
Industrial emissions of volatile organic compounds (VOCs) directly impact air quality downwind of facilities and contribute to regional ozone and secondary organic aerosol production. Positive matrix factorization (PMF) is often used to apportion VOCs to their respective sources using measurement data collected at fixed sites, for example air quality monitoring stations. Here, we apply PMF analysis to high time-resolution VOC measurement data collected both while stationary and while moving using a mobile monitoring platform. The stationary monitoring periods facilitated the extraction of representative industrial VOC source profiles while the mobile monitoring periods were critical for the spatial identification of VOC hotspots. Data were collected over five days in a heavily industrialized region of southwestern Ontario containing several refineries, petrochemical production facilities and a chemical waste disposal facility. Factors associated with petroleum, chemical waste and rubber production were identified and ambient mixing ratios of selected aromatic, unsaturated and oxygenated VOCs were apportioned to local and background sources. Fugitive emissions of benzene, highly localized and predominantly associated with storage, were found to be the dominant local contributor to ambient benzene mixing ratios measured while mobile. Toluene and substituted aromatics were predominantly associated with refining and traffic, while methyl ethyl ketone was linked to chemical waste handling. The approach described here facilitates the apportionment of VOCs to their respective local industrial sources at high spatial and temporal resolution. This information can be used to identify problematic source locations and to inform VOC emission abatement strategies.

15 February 2023 in Environmental Pollution
Verified
Journal Article
Closed access
USUwayemi Sofowote
Uwayemi Sofowote
DMDennis Mooibroek
Dennis Mooibroek
RHRobert Healy
Robert Healy
JDJerzy Debosz
Jerzy Debosz
AMAnthony Munoz
Anthony Munoz
PHPhilip K. Hopke
Philip K. Hopke

6 August 2013 in Journal of the Air & Waste Management Association
Verified
Journal Article
Closed access
USUwayemi Sofowote
Uwayemi Sofowote
YSYushan Su
Yushan Su
MBMelynda M. Bitzos
Melynda M. Bitzos
AMAnthony Munoz
Anthony Munoz
Tapered element oscillating microbalances equipped with sample equilibration system (TEOM-SES) used by the province of Ontario for the ambient monitoring of PM2.5 (particulate matter with an aerodynamic diameter ≤2.5 µm) in its air quality index (AQI) network were collocated with the Synchronized Hybrid Ambient Real-time Particulate monitor (SHARP 5030) at two monitoring sites for a period spanning approximately 2 years to determine the similarities and differences between the measurement outputs of both instrumental systems. Due mainly to mass loss observed with the TEOM-SES in cooler months, the province has recently switched its PM2.5 instrumentation at all stations in its monitoring network from the TEOM-SES to the SHARP 5030, which has the U.S. Environmental Protection Agency (EPA) Federal Equivalent Method (FEM) Class III designation. Thus, it has become imperative to develop corrections for historical and future TEOM measurements for the purpose of making them more agreeable to the new FEM method. This work details the authors’ multiple linear regression analyses (MLRAs) of particulate matter data from both instrumental monitors, with the inclusion of operational parameters of physicochemical relevance for both cases of transformations of historical TEOM and TEOM measurements to be made in the future. For historical TEOM data, it was observed that the transformations only benefited winter and fall months. Furthermore, comparisons of the transformed historical TEOM data with PM2.5 concentrations determined from the Federal Reference Method (FRM) sampler at seven locations within the province showed marked improvements over the observed TEOM-FRM comparisons. Implications:This work provides a path to correcting the historically observed underreporting of particulate mass in winter and fall in Ontario by making the TEOM-based continuous data resemble the new FEM outputs (in this case, more SHARP-like). It is possible that the transformation of mainly winter TEOM data as detailed in this work may potentially lead to revisions in historical annual composite mean PM2.5 concentrations and total annual number of days PM2.5 exceeded the Canada-wide Standard (CWS) metric across the province.

23 November 2023 in Environmental Pollution
Verified
Journal Article
Open access
MYMahmoud M. Yassine
Mahmoud M. Yassine
EDEwa Dabek-Zlotorzynska
Ewa Dabek-Zlotorzynska
VCValbona Celo
Valbona Celo
USUwayemi Sofowote
Uwayemi Sofowote
DMDennis Mooibroek
Dennis Mooibroek
PHPhilip K. Hopke
Philip K. Hopke
PM2.5 was sampled over a seven-year period (2013-2019) at two locations ∼50 km apart in Southern Ontario (concurrently for five years: 2015-2019). One is a heavily industrialized site (Hamilton), while the other was a rural site (Simcoe). To assess the impact of industrialization on the composition and sources of PM affecting air quality in these two locations, positive matrix factorization coupled with dispersion normalization (DN-PMF) was used to identify six and eight factors at Simcoe and Hamilton, respectively. The Simcoe factors in order of diminishing PM mass contribution were: particulate sulphate (pSO4), secondary organic aerosol (SOA), crustal matter, particulate nitrate (pNO3), biomass burning, and vehicular emissions. At Hamilton, the effects of industrialization were observed by the ∼36% higher average ambient PM2.5 concentration for the study period as well as the presence of factors unique to metallurgy, i.e., coking and steelmaking, compared to Simcoe. The coking and steelmaking factors contributed ∼15% to the PM mass at Hamilton. Seasonal variants of appropriate nonparametric trend tests with the associated slopes (Sen's) were used to assess statistically significant changes in the factor contributions to PM2.5 over time. Specifically at Hamilton, a significant decline in PM contributions was noted for coking (-0.03 μg/m³/yr or -4.1%/yr) while steelmaking showed no statistically significant decline over the study period. Other factors at Hamilton that showed statistically significant declines over the study period were: pSO4 (-0.27 μg/m³/yr or -12.6%/yr), biomass burning (-0.05 μg/m³/yr or -9.02%/yr), crustal matter (-0.03 μg/m³/yr or -5.28%/yr). These factors mainly accounted for the significant decline in PM2.5 over the study period (-0.35 μg/m³/yr or -4.24%/yr). This work shows the importance of long-term monitoring in assessing the unique contributions and temporal changes of industrialization on air quality in Ontario and similarly affected locations.