David Murphy

Dr. David Murphy

orcid

Research Focus & Metrics

Academic Career Length

35Years (1992-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 April 2023 in American Journal of Ophthalmology
Verified
Journal Article
Closed access
MHMichael T. Heath
Michael T. Heath
LMLakshman Mulpuri
Lakshman Mulpuri
EKEden Kimiagarov
Eden Kimiagarov
RPRaj P. Patel
Raj P. Patel
DMDavid Murphy
David Murphy
Kamran RiazKamran Riaz
Kamran Riaz

1 March 2023 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
Asher KhanAsher Khan
Asher Khan
NRNeal Ba Rangu
Neal Ba Rangu
DMDavid Murphy
David Murphy
DCDavid L. Cooke
David L. Cooke
RSRhea L. Siatkowski
Rhea L. Siatkowski
Kamran RiazKamran Riaz
Kamran Riaz
Purpose: To compare the prediction accuracy of standard keratometry (K) and total keratometry (TK) for intraocular lens (IOL) power calculation in eyes undergoing combined cataract surgery and Descemet membrane endothelial keratoplasty (triple DMEK). Setting: Tertiary care academic referral center. Design: Retrospective case series. Methods: Review of 83 eyes (63 patients) that underwent triple DMEK between 2019 and 2021. Biometry measurements were obtained using a swept-source optical biometer (IOLMaster 700). 63 eyes were used for statistical analysis. Mean error, mean absolute error (MAE), SD, median absolute error, maximum absolute error, root mean squared prediction error, and the percentage of eyes within prediction errors of ±0.50 diopters (D) and ±1.00 D were calculated for 9 multivariate and third-generation formulas using K and TK values (Barrett Universal II, Yeo EVO 2.0, Cooke K6, Kane, Pearl-DGS, Haigis, Holladay 1, Hoffer Q, and SRK/T). Formulas were additionally tested by using the prediction for an IOL power 1 D below the IOL used (IOLup1D). Results: For all formulas, MAE was lower for K than for TK by an average of 0.21 D. The lowest MAE value observed was 0.67 D for “adjusted” SRK/T using K, and the highest MAE values observed were 1.24 D and 1.24 D for nonadjusted Hoffer Q and Haigis using TK, respectively. Overall, lower MAE values were observed for multivariate formulas and SRK/T. Conclusions: In triple DMEK eyes, the prediction accuracy of K was higher than that of TK. The most accurate formulas were SRK/T and multivariate formulas using K with the IOLup1D adjustment.

9 November 2022 in American Journal of Ophthalmology
Verified
Journal Article
Closed access
DCDavid L. Cooke
David L. Cooke
Kamran RiazKamran Riaz
Kamran Riaz
DMDavid Murphy
David Murphy
OFOliver Findl
Oliver Findl
ALAchim Langenbucher
Achim Langenbucher
JWJascha Wendelstein
Jascha Wendelstein

9 November 2021 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
DCDavid L. Cooke
David L. Cooke
RWRhonda Mmsc Waldron
Rhonda Mmsc Waldron
GSGiacomo Savini
Giacomo Savini
Kamran RiazKamran Riaz
Kamran Riaz
LTLeonardo Taroni
Leonardo Taroni
FGFabio Guaraldi
Fabio Guaraldi
Purpose: To compare axial length (AL) measurements obtained by optical biometry (OB) and immersion ultrasound (iUS) to investigate the agreement between the 2 techniques and how to use OB constants for eyes with AL by iUS. Setting: Multicenter study. Design: Retrospective observational case series. Methods: Agreement between OB and iUS ALs was investigated in 4 subsets. Also, in a test database, the prediction error (PE) for iUS AL was assessed with 4 methods: (1) data-optimized constants; (2) user group for laser interference biometry (ULIB) constants with iUS biometry; (3) with recalibrated AL; and (4) ULIB A-constant − 0.23. Results: A Combined 1970 eyes were measured with both OB and iUS biometry. OB mean AL was 0.0873 mm longer than iUS AL. The latter was made equivalent to OB ALs with this equation: Recalibrated iUS AL = 1.0228 × iUS AL − 0.4556. In a fifth database (n = 1079) with OB AL measurements only, after AL was artificially shortened by 0.0873 mm, the original A-constant had to be reduced by 0.23 to maintain a zero PE. In a sixth database (n = 127) with iUS AL, the original ULIB A-constant provided the poorest outcomes. Using either recalibrated iUS AL or ULIB A-constant − 0.23 zeroed out the mean PE and achieved the lowest median absolute error. Conclusions: AL measurements by iUS can be used with ULIB constants for OB by subtracting 0.23 from the A-constant; alternatively, the iUS AL may be recalibrated. The recalibrated iUS AL should be treated as AL measurements obtained by OB. It is longer than iUS AL in long eyes.

15 October 2024 in Cells
Verified
Journal Article
Open access
PDF file
PEPaulina Escandon
Paulina Escandon
ACAlexander Choi
Alexander Choi
SMSteve Mabry
Steve Mabry
SNSarah E Nicholas
Sarah E Nicholas
RCRebecca L. Cunningham
Rebecca L. Cunningham
Dimitrios KaramichosDimitrios Karamichos
Dimitrios Karamichos
Keratoconus (KC) is a corneal thinning dystrophy that leads to visual impairment. While the cause of KC remains poorly understood, changes in sex hormone levels have been correlated with KC development. This study investigated circulating gonadotropin-releasing hormone (GnRH) in control and KC subjects to determine if this master hormone regulator is linked to the KC pathology. Plasma and saliva were collected from KC subjects (n = 227 and n = 274, respectively) and non-KC controls (n = 58 and n = 101, respectively), in concert with patient demographics and clinical features. GnRH levels in both plasma and saliva were significantly lower in KC subjects compared to controls. This finding was retained in plasma when subjects were stratified based on age, sex, and KC severity. Control and KC corneal fibroblasts (HKCs) stimulated with recombinant GnRH protein in vitro revealed significantly increased luteinizing hormone receptor by HKCs and reduced expression of α-smooth muscle actin with treatment suggesting that GnRH may modulate hormonal and fibrotic responses in the KC corneal stroma. Further studies are needed to reveal the role of the hypothalamic–pituitary–gonadal axis in the onset and progression of KC and to explore this pathway as a novel therapeutic target.

4 March 2022 in Cornea
Verified
Journal Article
Closed access
Kamran RiazKamran Riaz
Kamran Riaz
MGMohsain S. Gill
Mohsain S. Gill
DMDavid Murphy
David Murphy
KDKAI DING
KAI DING
MKMahmoud A. Khaimi
Mahmoud A. Khaimi
Purpose: The purpose of this study was to report clinical outcomes of ab interno canaloplasty (ABiC) with the iTrack microcatheter (Nova Eye Medical, Fremont, CA) for surgical management of intraocular pressure (IOP) in postkeratoplasty patients. Methods: This study was a single-center retrospective case series of postkeratoplasty eyes undergoing ABiC. Efficacy was evaluated based on graft survivability and mean reduction in IOP at 12 months postoperatively. Secondary end points consisted of visual acuity outcomes, number of topical hypotensive medications, and rate of complications. Results: ABiC was successfully performed in 17 eyes after keratoplasty (8 penetrating keratoplasty, 6 DSAEK, 2 penetrating keratoplasty + DSAEK, and 1 DMEK) with elevated IOP refractory to topical hypotensive medications. The baseline mean IOP was 26.2 ± 8.4 mm Hg and reduced significantly to 15.0 ± 4.21 mm Hg at 6 months and 13.0 ± 2.99 mm Hg at 12 months (P < 0.005). The best-corrected visual acuity improved from 0.61 ± 0.55 logMAR at baseline to 0.47 ± 0.59 and 0.49 ± 0.64 at 6 and 12 months, respectively, following ABiC (not statistically significant: P = 0.6769). The baseline mean number of topical hypotensive medications was 3.7 ± 1.8 and reduced to 2.7 ± 1.4 and 2.9 ± 1.3 at 6 and 12 months, respectively (P = 0.096). One patient developed a hyphema which required anterior chamber washout. One patient required additional glaucoma surgery 19 months after ABiC. No patients experienced graft failure. Conclusions: ABiC is a clinically safe and effective treatment that can be performed in postkeratoplasty patients to reduce IOP for at least 1 year without any significant complications.