Aim: This study aimed to compare the accuracy and reproducibility of the EinScan H2 (SHINING 3D, Hangzhou, China) with the Vectra M3 3D Imaging System (Canfield Scientific, Parsippany, NJ, USA) and with direct anthropometric measurements. Methods: Twenty subjects were scanned with two different facial scanning systems. Linear measurements were compared with direct anthropometric measurements taken on the patient’s face, while area analysis (forehead, tip of the nose, chin, right and left cheek) was performed by overlaying scans after best-fit alignment using the Geomagic Control X v2020.1.1 program. Statistical analysis was conducted using IBM SPSS v28 software, except for the power analysis, which was conducted using R v4.2.1. Results: The intraclass correlation coefficient (ICC) showed high repeatability for both the linear and point measurements, with all values exceeding 0.90. The paired-sample Wilcoxon test revealed no significant differences (p > 0.05) between the linear measurements, indicating consistency across the three measurement methods. Point analysis using the single-sample Wilcoxon test also showed no significant differences (p > 0.05) in the median values. The differences between the two scanning instruments for cephalometric points ranged from 0.5 mm to −0.5 mm, except for the subnasal point (0.73 mm). Over 70% of the surface areas analyzed showed overlapping within the highly reproducible range (0.5 mm to −0.5 mm). Conclusion: Both scanning systems investigated in this study proved to be accurate and reliable for capturing 3D images of the patient’s face.
27 November 2025 in Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie
Background: This study aims to investigate the biomechanical characteristics of orthodontic miniscrews manufactured for use in infrazygomatic crests. Methods: This study analyzed the Zygomatic Spider Screw (HDC, Thiene, Italy), considering four variables: length, insertion angle, insertion depth, support thickness. Twenty-two configurations were tested on 66 miniscrews, all with a diameter of 2 mm, and were inserted into D1 bone-like supports. After compression tests, the deformation angles and linear distances between the tips of the miniscrews were measured. Results: Power analysis showed 99% power for the deformation angles and linear distance. The ICC indicated the good repeatability of the results, with values above 0.70. The mean maximum load values ranged from 21.5 N to 228.8 N, while the mean deformations ranged from 0.45 mm to 2.26 mm. Miniscrews with greater insertion depths (6 and 8 mm) exhibited approximately twice the average deformation (1.5 mm) compared to those inserted at 2 and 4 mm (0.71 mm). It was noted that miniscrews with higher deformation and a lower applied load were those with a working part length of 10 mm and an insertion depth of 2 mm, while those with lower deformation and a better load-bearing capacity were those with a working part length of 6 mm that were fully inserted into the bone support. Conclusions: The miniscrew design and insertion depth significantly affect biomechanical properties. It is advisable to maximize the insertion depth and minimize the distance between the support and the point of force application. The insertion angle did not prove to be a determining factor in the load.