Marta Calza

Dr. Marta Calza


Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 January 2025 in Applied Sciences
Verified
Journal Article
Open access
PDF file
FPFederica Pellitteri
Federica Pellitteri
MCMarta Calza
Marta Calza
GBGiacomo Baldi
Giacomo Baldi
MMMatteo De Maio
Matteo De Maio
LLLuca Lombardo
Luca Lombardo
Aim: This study aimed to compare the accuracy and reproducibility of the EinScan H2 (SHINING 3D, Hangzhou, China) with the Vectra M3 3D Imaging System (Canfield Scientific, Parsippany, NJ, USA) and with direct anthropometric measurements. Methods: Twenty subjects were scanned with two different facial scanning systems. Linear measurements were compared with direct anthropometric measurements taken on the patient’s face, while area analysis (forehead, tip of the nose, chin, right and left cheek) was performed by overlaying scans after best-fit alignment using the Geomagic Control X v2020.1.1 program. Statistical analysis was conducted using IBM SPSS v28 software, except for the power analysis, which was conducted using R v4.2.1. Results: The intraclass correlation coefficient (ICC) showed high repeatability for both the linear and point measurements, with all values exceeding 0.90. The paired-sample Wilcoxon test revealed no significant differences (p > 0.05) between the linear measurements, indicating consistency across the three measurement methods. Point analysis using the single-sample Wilcoxon test also showed no significant differences (p > 0.05) in the median values. The differences between the two scanning instruments for cephalometric points ranged from 0.5 mm to −0.5 mm, except for the subnasal point (0.73 mm). Over 70% of the surface areas analyzed showed overlapping within the highly reproducible range (0.5 mm to −0.5 mm). Conclusion: Both scanning systems investigated in this study proved to be accurate and reliable for capturing 3D images of the patient’s face.

27 November 2025 in Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie
Verified
Journal Article
Closed access
PDF file
FCFrancesca Cremonini
Francesca Cremonini
FPFrancesca Pavan
Francesca Pavan
MCMarta Calza
Marta Calza
MPMario Palone
Mario Palone
LGLuis T. Huanca Ghislanzoni
Luis T. Huanca Ghislanzoni
LLLuca Lombardo
Luca Lombardo

19 August 2025 in Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie
Verified
Journal Article
Closed access
PDF file
FCFrancesca Cremonini
Francesca Cremonini
FPFrancesca Pavan
Francesca Pavan
MCMarta Calza
Marta Calza
MPMario Palone
Mario Palone
LGLuis T. Huanca Ghislanzoni
Luis T. Huanca Ghislanzoni
LLLuca Lombardo
Luca Lombardo

9 May 2025 in Sci
Verified
Journal Article
Open access
PDF file
MPMario Palone
Mario Palone
DTDavide Tucci
Davide Tucci
MCMarta Calza
Marta Calza
NANiki Arveda
Niki Arveda
FCFrancesca Cremonini
Francesca Cremonini
LLLuca Lombardo
Luca Lombardo
Background: This study aims to investigate the biomechanical characteristics of orthodontic miniscrews manufactured for use in infrazygomatic crests. Methods: This study analyzed the Zygomatic Spider Screw (HDC, Thiene, Italy), considering four variables: length, insertion angle, insertion depth, support thickness. Twenty-two configurations were tested on 66 miniscrews, all with a diameter of 2 mm, and were inserted into D1 bone-like supports. After compression tests, the deformation angles and linear distances between the tips of the miniscrews were measured. Results: Power analysis showed 99% power for the deformation angles and linear distance. The ICC indicated the good repeatability of the results, with values above 0.70. The mean maximum load values ranged from 21.5 N to 228.8 N, while the mean deformations ranged from 0.45 mm to 2.26 mm. Miniscrews with greater insertion depths (6 and 8 mm) exhibited approximately twice the average deformation (1.5 mm) compared to those inserted at 2 and 4 mm (0.71 mm). It was noted that miniscrews with higher deformation and a lower applied load were those with a working part length of 10 mm and an insertion depth of 2 mm, while those with lower deformation and a better load-bearing capacity were those with a working part length of 6 mm that were fully inserted into the bone support. Conclusions: The miniscrew design and insertion depth significantly affect biomechanical properties. It is advisable to maximize the insertion depth and minimize the distance between the support and the point of force application. The insertion angle did not prove to be a determining factor in the load.