Tianyi Yuan

Dr. Tianyi Yuan


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 November 2022 in Sensors
Verified
Journal Article
Open access
PDF file
Tengfei longTengfei long
Tengfei long
YXYi Xu
Yi Xu
HZHaidong Zou
Haidong Zou
LLLina Lu
Lina Lu
TYTianyi Yuan
Tianyi Yuan
YMYingyan Ma
Yingyan Ma
Pixel pitch calibration is an essential step to make the fundus structures in the fundus image quantitatively measurable, which is important for the diagnosis and treatment of many diseases, e.g., diabetes, arteriosclerosis, hereditary optic atrophy, etc. The conventional calibration approaches require the specific parameters of the fundus camera or several specially shot images of the chess board, but these are generally not accessible, and the calibration results cannot be generalized to other cameras. Based on automated ROI (region of interest) and optic disc detection, the diameter ratio of ROI and optic disc (ROI–disc ratio) is quantitatively analyzed for a large number of fundus images. With the prior knowledge of the average diameter of an optic disc in fundus, the pixel pitch can be statistically estimated from a large number of fundus images captured by a specific camera without the availability of chess board images or detailed specifics of the fundus camera. Furthermore, for fundus cameras of FOV (fixed field-of-view), the pixel pitch of a fundus image of 45° FOV can be directly estimated according to the automatically measured diameter of ROI in the pixel. The average ROI–disc ratio is approximately constant, i.e., 6.404 ± 0.619 in the pixel, according to 40,600 fundus images, captured by different cameras, of 45° FOV. In consequence, the pixel pitch of a fundus image of 45° FOV can be directly estimated according to the automatically measured diameter of ROI in the pixel, and results show the pixel pitches of Canon CR2, Topcon NW400, Zeiss Visucam 200, and Newvision RetiCam 3100 cameras are 6.825 ± 0.666 μm, 6.625 ± 0.647 μm, 5.793 ± 0.565 μm, and 5.884 ± 0.574 μm, respectively. Compared with the manually measured pixel pitches, based on the method of ISO 10940:2009, i.e., 6.897 μm, 6.807 μm, 5.693 μm, and 6.050 μm, respectively, the bias of the proposed method is less than 5%. Since our method doesn’t require chess board images or detailed specifics, the fundus structures on the fundus image can be measured accurately, according to the pixel pitch obtained by this method, without knowing the type and parameters of the camera.

22 October 2024 in Toxics
Verified
Journal Article
Open access
PDF file
TYTianyi Yuan
Tianyi Yuan
MCMinna Cheng
Minna Cheng
YMYingyan Ma
Yingyan Ma
HZHaidong Zou
Haidong Zou
Haidong KanHaidong Kan
Haidong Kan
SLSenlin Lin
Senlin Lin
(1) Objective: This study investigated the relationship between long-term particulate matter (PM2.5) exposure and optic disc parameters—vertical cup-to-disc ratio (vCDR), vertical optic disc diameter (vDD), and vertical optic cup diameter (vCD)—in patients with type 2 diabetes mellitus (T2DM). (2) Methods: A cross-sectional analysis was conducted using data from 65,750 T2DM patients in the 2017–2018 Shanghai Cohort Study of Diabetic Eye Disease (SCODE). Optic disc parameters were extracted from fundus images, and PM2.5 exposure was estimated using a random forest model incorporating satellite and meteorological data. Multivariate linear regression models were applied, adjusting for confounders including age, gender, body mass index, blood pressure, glucose, time of T2DM duration, smoking, drinking, and physical exercise. (3) Results: A 10 μg/m3 increase in PM2.5 exposure was associated with significant reductions in vCDR (−0.008), vDD (−42.547 μm), and vCD (−30.517 μm) (all p-values < 0.001). These associations persisted after sensitivity analyses and adjustments for other pollutants like O3 and NO2. (4) Conclusions: Long-term PM2.5 exposure is associated with detrimental changes in optic disc parameters in patients with T2DM, suggesting possible optic nerve atrophy. Considering the close relationship between the optic nerve and the central nervous system, these findings may also reflect broader neurodegenerative processes.