The brain is known to be active even when not performing any overt cognitive tasks, and often it engages in involuntary mind wandering. This resting state has been extensively characterized in terms of fMRI-derived brain networks. However, an alternate method has recently gained popularity: EEG microstate analysis. Proponents of microstates postulate that the brain discontinuously switches between four quasi-stable states defined by specific EEG scalp topologies at peaks in the global field potential (GFP). These microstates are thought to be “atoms of thought,” involved with visual, auditory, salience, and attention processing. However, this method makes some major assumptions by excluding EEG data outside the GFP peaks and then clustering the EEG scalp topologies at the GFP peaks, assuming that only one microstate is active at any given time. This study explores the evidence surrounding these assumptions by studying the temporal dynamics of microstates and its clustering space using tools from dynamical systems analysis, fractal, and chaos theory to highlight the shortcomings in microstate analysis. The results show evidence of complex and chaotic EEG dynamics outside the GFP peaks, which is being missed by microstate analysis. Furthermore, the winner-takes-all approach of only one microstate being active at a time is found to be inadequate since the dynamic EEG scalp topology does not always resemble that of the assigned microstate, and there is competition among the different microstate classes. Finally, clustering space analysis shows that the four microstates do not cluster into four distinct and separable clusters. Taken collectively, these results show that the discontinuous description of EEG microstates is inadequate when looking at nonstationary short-scale EEG dynamics.
In this paper we present a simple and fast technique for correcting high amplitude artifacts that contaminate EEG signals. Examples of such artifacts are ocular movement, eye blinks, head movement, etc. Since the measured EEG data can be modeled as a linear combination of brain sources and artifacts, the proposed technique is based on multiplying the observed data matrix by a blocking matrix that has the effect of blocking high amplitude artifacts, while linearly transforming the other sources without any distortion. The advantages of using this technique are: 1) it is relatively fast, so it can be applied in real time, 2) it is completely automatic, and 3) can be successfully applied to signals which fail with ICA-based algorithms.
24 October 2018 in IEEE Journal of Biomedical and Health Informatics
Mismatch Negativity (MMN) is a component of the event-related potential (ERP) that is elicited through an odd-ball paradigm. The existence of the MMN in a coma patient has a good correlation with coma emergence; however, this component can be difficult to detect. Previously, MMN detection was based on visual inspection of the averaged ERPs by a skilled clinician, a process which is expensive and not always feasible in practice. In this paper we propose a practical machine learning (ML) based approach for detection of the MMN component, thus improving the accuracy of prediction of emergence from coma. Further, the method can operate on an automatic and continuous basis, thus alleviating the need for clinician involvement. The proposed method is capable of MMN detection over intervals as short as two minutes. This finer time resolution enables identification of waxing and waning cycles of a conscious state. An auditory odd-ball paradigm was applied to 22 healthy subjects and 2 coma patients. A coma patient is tested by measuring the similarity of the patient's ERP responses with the aggregate healthy responses. Because the training process for measuring similarity requires only healthy subjects, the complexity and practicality of training procedure of the proposed method are greatly improved relative to training on coma patients directly. Since there are only two coma patients involved with this study, the results are reported on a very preliminary basis. Preliminary results indicate we can detect the MMN component with an accuracy of 92.7% on healthy subjects. The method successfully predicted emergence in both coma patients when conventional methods failed. The proposed method for collecting training data using exclusively healthy subjects is a novel approach that may prove useful in future, unrelated studies where machine learning methods are used.
Heart and lung sounds are crucial for healthcare monitoring. Recent improvements in stethoscope technology have made it possible to capture patient sounds with enhanced precision. In this dataset, we used a digital stethoscope to capture both heart and lung sounds, including individual and mixed recordings. To our knowledge, this is the first dataset to offer both separate and mixed cardiorespiratory sounds. The recordings were collected from a clinical manikin, a patient simulator designed to replicate human physiological conditions, generating clean heart and lung sounds at different body locations. This dataset includes both normal sounds and various abnormalities (i.e., murmur, atrial fibrillation, tachycardia, atrioventricular block, third and fourth heart sound, wheezing, rhonchi, pleural rub, fine crackle, and coarse crackle sounds). The dataset includes audio recordings of chest examinations performed at different anatomical locations, as determined by specialist nurses. Each recording has been enhanced using frequency filters to highlight specific sound types. This dataset is useful for applications in artificial intelligence, such as automated cardiopulmonary disease detection, sound classification, unsupervised separation techniques, and deep learning algorithms related to audio signal processing.
12 June 2019 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
There has been increased effort to understand the neurophysiological effects of concussion aimed to move diagnosis and identification beyond current subjective behavioural assessments that suffer from poor sensitivity. Recent evidence suggests that event-related potentials (ERPs) measured with electroencephalography (EEG) are persistent neurophysiological markers of past concussions. However, as such evidence is limited to group-level analyses, the extent to which they enable concussion detection at the individual-level is unclear. One promising avenue of research is the use of machine learning to create quantitative predictive models that can detect prior concussions in individuals. In this study we translate the recent group-level findings from ERP studies of concussed individuals into a machine learning framework for performing single-subject prediction of past concussion. We found that a combination of statistics of single-subject ERPs and wavelet features yielded a classification accuracy of 81% with a sensitivity of 82% and a specificity of 80%, improving on current practice. Notably, the model was able to detect concussion effects in individuals who sustained their last injury as much as 30 years earlier. However, failure to detect past concussions in a subset of individuals suggests that the clear effects found in group-level analyses may not provide us with a full picture of the neurophysiological effects of concussion.
3 March 2021 in IEEE Transactions on Biomedical Engineering
Objective: Schizophrenia is a severe mental disorder associated with nerobiological deficits. Auditory oddball P300 have been found to be one of the most consistent markers of schizophrenia. The goal of this study is to find quantitative features that can objectively distinguish patients with schizophrenia (SCZs) from healthy controls (HCs) based on their recorded auditory odd-ball P300 electroencephalogram (EEG) data. Methods: Using EEG dataset, we develop a machine learning (ML) algorithm to distinguish 57 SCZs from 66 HCs. The proposed ML algorithm has three steps. In the first step, a brain source localization (BSL) procedure using the linearly constrained minimum variance (LCMV) beamforming approach is employed on EEG signals to extract source waveforms from 30 specified brain regions. In the second step, a method for estimating effective connectivity, referred to as symbolic transfer entropy (STE), is applied to the source waveforms. In the third step the ML algorithm is applied to the STE connectivity matrix to determine whether a set of features can be found that successfully discriminate SCZ from HC. Results: The findings revealed that the SCZs have significantly higher effective connectivity compared to HCs and the selected STE features could achieve an accuracy of 92.68%, with a sensitivity of 92.98% and specificity of 92.42%. Conclusion: The findings imply that the extracted features are from the regions that are mainly affected by SCZ and can be used to distinguish SCZs from HCs. Significance : The proposed ML algorithm may prove to be a promising tool for the clinical diagnosis of schizophrenia.