Soram Oh

Dr. Soram Oh

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2019 in Restorative Dentistry & Endodontics
Verified
Journal Article
Open access
PDF file
YYYeon-Jee Yoo
Yeon-Jee Yoo
HPHiran Perinpanayagam
Hiran Perinpanayagam
SOSoram Oh
Soram Oh
AKAREUM KIM
AREUM KIM
SHSeung Hyun Han
Seung Hyun Han
Kee-Yeon KumKee-Yeon Kum
Kee-Yeon Kum
Yoo YJ, et al. Restor Dent Endod. 2018 Nov;44:e7. https://doi.org/10.5395/rde.2019.44.e7

22 September 2020 in Bioinorganic Chemistry and Applications
Verified
Journal Article
Open access
PDF file
SLSoo-Hyuk Lee
Soo-Hyuk Lee
SOSoram Oh
Soram Oh
AAAdel Saeed Al-Ghamdi
Adel Saeed Al-Ghamdi
AMAyman Omar Mandorah
Ayman Omar Mandorah
KKKee-Yeon Kum
Kee-Yeon Kum
SCSeok Woo Chang
Seok Woo Chang
The objective of root canal obturation is to achieve a fluid-tight seal. Recently, GuttaFlow bioseal (GB), a root canal sealer composed of polydimethylsiloxane, gutta-percha particles, and bioactive glass ceramics, has been developed, to enhance the sealing ability of root canal filling material. The objective of this study was to assess the sealing ability of GB using a subnanoliter-scaled fluid-flow measuring device and to compare with that of AH Plus (AH). The fluid flow in root canal-filled teeth using either gutta-percha cone (GP) with AH (GAR; n = 10) or GP with GB (GBR; n = 10) and in GP inserted in AH blocks (GA; n = 10) or GP inserted in GB blocks (GB; n = 10) was measured. In addition, fluid flow in sealer blocks of AH (A; n = 10) and GB (B; n = 10), which served as negative controls, was measured. Root canal-filled teeth using GP without any sealer (GR) acted as positive controls (n = 10). The leakage was obtained by calculating the volume of moved water by time (s), after stabilization of the fluid flow was achieved. Statistical analysis was performed using the Kruskal–Wallis test and Mann–Whitney U-test with Bonferroni correction. A p value less than 0.00238 (0.05/21) was considered significantly different. The mean leakages (nL/s) in the groups are as follows: GAR, 0.0958 ± 0.0543; GBR, 0.0223 ± 0.0246; GA, 0.0644 ± 0.0803; GB, 0.0267 ± 0.0182; A, 0.0055 ± 0.0057; B, 0.0052 ± 0.005; and GR, 0.2892 ± 0.3018. The mean leakage in the GBR group was lower than that in the GAR group (p = 0.001), while the mean leakages in the GA and GB groups were not significantly different. GuttaFlow bioseal can be useful in single-cone obturation technique.

18 July 2018 in Materials
Verified
Journal Article
Open access
PDF file
SHSukhyun Hwang
Sukhyun Hwang
SCShin Hye Chung
Shin Hye Chung
JLJung-Tae Lee
Jung-Tae Lee
YKYong-Tae Kim
Yong-Tae Kim
YKYoo Jin Kim
Yoo Jin Kim
In-Sung YeoIn-Sung Yeo
In-Sung Yeo
This study investigated the influences of acidity, ethanol, and pigment on the optical properties, microhardness, and surface roughness (Ra) of a nanohybrid dental composite resin. A total of 108 disc-shaped specimens were fabricated using a nanohybrid dental composite and allocated into 36 different storage solutions according to the levels of pH (2.0, 3.0, 4.0, and 5.5), ethanol (0%, 20%, and 40%), and anthocyanin pigment (0%, 2.5%, and 12.5%). Measurements of the colorimetric parameter and the amount of color change (ΔE), translucency parameter (TP), microhardness, and surface roughness (Ra) were performed at 24 h (baseline), 1-, 2-, 3-, and 4-weeks. Repeated measures of analysis of variance (ANOVA) with a Tukey honestly significant difference test and Pearson correlation analysis were carried out (α = 0.05). Pigment of 12.5% or 40% ethanol significantly increased the ΔE (P < 0.001, P = 0.048, respectively). Pigment of 2.5% or 12.5% significantly decreased the TP (P = 0.001, P < 0.001, respectively). Microhardness of composite resin stored in pH 2.0, 3.0, 4.0 solution was lower than that for pH 5.5 (P < 0.001). Pigment, ethanol, and pH did not influence the Ra. TP change and ΔE, and Ra and ΔE had a significant positive correlation (P < 0.05). In conclusion, pigment and ethanol levels influenced the optical properties and acidity affected the microhardness of composite resin.

1 January 2016 in Restorative Dentistry & Endodontics
Verified
Journal Article
Open access
PDF file
SOSoram Oh
Soram Oh
HPHiran Perinpanayagam
Hiran Perinpanayagam
YLYoon Lee
Yoon Lee
JKJae-Won Kum
Jae-Won Kum
YYYeon-Jee Yoo
Yeon-Jee Yoo
Kee-Yeon KumKee-Yeon Kum
Kee-Yeon Kum
Oh S, et al. Restor Dent Endod. 2016 Feb;41(1):12-21. https://doi.org/10.5395/rde.2016.41.1.12

1 January 2019 in Journal of Periodontal & Implant Science
Verified
Journal Article
Open access
PDF file
SOSoram Oh
Soram Oh
SCShin Hye Chung
Shin Hye Chung
JHJI-Young Han
JI-Young Han
Oh S, et al. J Periodontal Implant Sci. 2019 Apr;49(2):90-104. https://doi.org/10.5051/jpis.2019.49.2.90

20 May 2019 in Materials
Verified
Journal Article
Open access
PDF file
GJGa youn Ju
Ga youn Ju
SOSoram Oh
Soram Oh
BLBum-Soon Lim
Bum-Soon Lim
HLHyun-Seung Lee
Hyun-Seung Lee
SCShin Hye Chung
Shin Hye Chung
The aim of this study was to evaluate the long term stability of shear bond strength (SBS) when 10-methacryloyloxydecyl dihydrogen phosphate (10-MDP) containing universal adhesive was used in the ceramic bracket bonding on dental zirconia. Twenty human maxillary incisors were collected. The ceramic bracket was bonded on the buccal enamel surface after the acid-etching and orthodontic primer application (Group CON). Sixty zirconia specimens were sintered, sandblasted and divided into three experimental groups; group CP—ceramic primer followed by an orthodontic primer; group U—universal adhesive; group CU—ceramic primer followed by a universal adhesive. For each specimen, the bracket was bonded onto the treated surface with composite resin (Transbond XT, 3M ESPE). The SBS tested before (CON0, CP0, U0, CU0) and after the artificial aging (CON1, CP1, U1, CU1). The data were statistically analyzed with the Kruskal–Wallis test at a significance level of 0.05. The mean SBS of CON0, CP0, U0 and CU0 were within the clinically acceptable range without significant differences. After the aging process, SBS decreased in all groups. Among the aged groups, CP1 showed the highest SBS. Based on the results, when bonding ceramic brackets to a dental zirconia surface, we can conclude that ceramic primer used with an orthodontic primer, rather than using a universal adhesive, is recommended.