Ugur Tamer

Prof. Ugur Tamer

Department of Analytical Chemistry, Faculty of Pharmacy, Gazi University, Ankara 06330, Turkey
orcid

Research Focus & Metrics

Academic Career Length

72Years (1955-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 August 2017 in Nature Materials
Verified
Journal Article
Closed access
Mehmet YilmazMehmet Yilmaz
Mehmet Yilmaz
EBEsra Babur
Esra Babur
MOMehmet Ozdemir
Mehmet Ozdemir
RGRebecca L. Gieseking
Rebecca L. Gieseking
YDYavuz Dede
Yavuz Dede
GDGokhan Demirel
Gokhan Demirel

1 December 2010 in The Analyst
Verified
Journal Article
Closed access
PDF file
BGBurcu Guven
Burcu Guven
NBNese Basaran-Akgul
Nese Basaran-Akgul
ETErhan Temur
Erhan Temur
UTUgur Tamer
Ugur Tamer
İBİsmail Hakkı Boyacı
İsmail Hakkı Boyacı
A method combining immunomagnetic separation (IMS) and surface-enhanced Raman scattering (SERS) was developed to enumerate Escherichia coli (E. coli). Gold-coated magnetic spherical nanoparticles were prepared by immobilizing biotin-labeled anti-E. coliantibodies onto avidin-coated magnetic nanoparticles and used in the separation and concentration of the E. colicells. Raman labels have been constructed using rod shaped gold nanoparticles coated with 5,5-dithiobis-(2-nitrobenzoic acid) (DTNB) and subsequently with a molecular recognizer. Then DTNB-labeled gold nanorods were interacted with gold-coated magnetic spherical nanoparticle-antibody-E. coli complex. The capture efficiency and calibration graphs were obtained and examined in different E. coli concentrations (101–107 cfu mL−1). The correlation between the concentration of bacteria and SERS signal was found to be linear within the range of 101–104 cfu mL−1 (R2 = 0.992). The limit of detection (LOD) and limit of quantification (LOQ) values of the developed method were found to be 8 and 24 cfu mL−1, respectively. The selectivity of the developed immunoassay was examined with Enterobacter aerogenes, Enterobacter dissolvens, and Salmonella enteriditis which did not produce any significant response. The ability of the immunoassay to detect E. coli in real water samples was also investigated and the results were compared with the experimental results from plate-counting methods. There was no significant difference between the methods that were compared (p > 0.05). This method is rapid and sensitive to target organisms with a total analysis time of less than 70 min.

1 May 2013 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
JBJulija Baniukevic
Julija Baniukevic
IBIsmail Hakki Boyaci
Ismail Hakki Boyaci
ABAkif Göktuğ Bozkurt
Akif Göktuğ Bozkurt
UTUgur Tamer
Ugur Tamer
Arũnas RamanavičiusArũnas Ramanavičius
Arũnas Ramanavičius
Almira RamanavicieneAlmira Ramanaviciene
Almira Ramanaviciene

1 February 2013 in Food Chemistry
Verified
Journal Article
Closed access
BÖBeril Özbalci
Beril Özbalci
İBİsmail Hakkı Boyaci
İsmail Hakkı Boyaci
ATAli Topcu
Ali Topcu
CKCem Kadılar
Cem Kadılar
UTUgur Tamer
Ugur Tamer

17 September 2009 in Journal of Nanoparticle Research
Verified
Journal Article
Closed access
PDF file
UTUgur Tamer
Ugur Tamer
YGYusuf Gündoğdu
Yusuf Gündoğdu
İBİsmail Hakkı Boyacı
İsmail Hakkı Boyacı
KPKadir Pekmez
Kadir Pekmez

1 September 2013 in Journal of Colloid and Interface Science
Verified
Journal Article
Closed access
VGVinod Gupta
Vinod Gupta
NANecip Atar
Necip Atar
MYMehmet Lütfi Yola
Mehmet Lütfi Yola
MEMerve Eryılmaz
Merve Eryılmaz
HTHilal Torul
Hilal Torul
ZÜZafer Üstündağ
Zafer Üstündağ