FERNANDO SANCHEZ QUETE

Mr. FERNANDO SANCHEZ QUETE

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2016 in Acta Tropica
Verified
Journal Article
Closed access
ECEliana Patricia Calvo
Eliana Patricia Calvo
FQFERNANDO SANCHEZ QUETE
FERNANDO SANCHEZ QUETE
Sandra Carolina Durán-CristianoSandra Carolina Durán-Cristiano
Sandra Carolina Durán-Cristiano
ISIsabel Sandoval
Isabel Sandoval
JCJaime E. Castellanos
Jaime E. Castellanos

21 September 2024 in Viruses
Verified
Journal Article
Open access
PDF file
GJGabrielle Jayme
Gabrielle Jayme
JLJu-Ling Liu
Ju-Ling Liu
JGJose Hector Galvez
Jose Hector Galvez
SRSarah Julia Reiling
Sarah Julia Reiling
SCSukriye Celikkol
Sukriye Celikkol
TSTerrance P. Snutch
Terrance P. Snutch
During the COVID-19 pandemic, the monitoring of SARS-CoV-2 RNA in wastewater was used to track the evolution and emergence of variant lineages and gauge infection levels in the community, informing appropriate public health responses without relying solely on clinical testing. As more sublineages were discovered, it increased the difficulty in identifying distinct variants in a mixed population sample, particularly those without a known lineage. Here, we compare the sequencing technology from Illumina and from Oxford Nanopore Technologies, in order to determine their efficacy at detecting variants of differing abundance, using 248 wastewater samples from various Quebec and Ontario cities. Our study used two analytical approaches to identify the main variants in the samples: the presence of signature and marker mutations and the co-occurrence of signature mutations within the same amplicon. We observed that each sequencing method detected certain variants at different frequencies as each method preferentially detects mutations of distinct variants. Illumina sequencing detected more mutations with a predominant lineage that is in low abundance across the population or unknown for that time period, while Nanopore sequencing had a higher detection rate of mutations that are predominantly found in the high abundance B.1.1.7 (Alpha) lineage as well as a higher sequencing rate of co-occurring mutations in the same amplicon. We present a workflow that integrates short-read and long-read sequencing to improve the detection of SARS-CoV-2 variant lineages in mixed population samples, such as wastewater.