14 February 2025 in Energies
Verified
Journal Article
Open access
PDF file
SASitthisak Audomsi
Sitthisak Audomsi
SWSupannika Wattana
Supannika Wattana
NUNarongkorn Uthathip
Narongkorn Uthathip
WSWorawat Sa-ngiamvibool
Worawat Sa-ngiamvibool
This study introduces a fuzzy logic-based two-degree-of-freedom PID (FL2DOF-PID) controller that is optimized using the Bee Algorithm (BA) to control the load frequency in a two-area linked power system that has both reheat thermal power plants and hydro power plants. To test how well it works, MATLAB/Simulink simulations compared it with PID, 2DOF-PID and fuzzy PID controllers, looking at overshoot, undershoot, settling time, steady-state error and the integral of absolute error (IAE). The results showed that FL2DOF-PID had the lowest RMSE (0.0054, 0.0089) and MAE (0.0041, 0.0065), as well as the smallest IAE (0.1308) and the smallest overshoot (69.3% less). It also had the fastest settling time (5.1528 s) and the smallest IAE (0.1338 less). These results showed that it works to reduce frequency changes, improve power flow stability and make the whole system more reliable under changing conditions.

13 September 2025 in Energies
Verified
Journal Article
Open access
PDF file
SBSarawoot Boonkirdram
Sarawoot Boonkirdram
SASitthisak Audomsi
Sitthisak Audomsi
WSWorawat Sa-ngiamvibool
Worawat Sa-ngiamvibool
WKWassana Kasemsin
Wassana Kasemsin
The increasing incorporation of renewable energy sources, such as photovoltaic and wind power, results in considerable variability and uncertainty within modern power systems, thereby complicating load frequency control. Conventional controllers, including PI and PID, often fail to provide sufficient performance in dynamic conditions. This study introduces a Two-Degree-of-Freedom PID (2DOF-PID) controller optimized through the Bee Algorithm (BA) for Load Frequency Control (LFC) in a two-area interconnected power system that includes renewable energy sources. The BA is employed to enhance controller parameters according to two objective functions: the Integral of Time-weighted Absolute Error (ITAE) and the Integral of Time-weighted Squared Error (ITSE). Simulation studies utilizing MATLAB/Simulink are conducted to evaluate the comparative effectiveness of PI, PID, and 2DOF-PID controllers. The results demonstrate that the 2DOF-PID controller consistently outperforms conventional PI and PID controllers in terms of frequency stability. The ITAE optimization of the 2DOF-PID results in a reduction in the ITAE index by more than 95% compared to PI and PID controllers, a decrease in settling time by approximately 40–60%, and a near elimination of overshoot and undershoot. Through ITSE optimization, the 2DOF-PID achieves an error reduction exceeding 90% and ensures smooth convergence with minimal oscillations. The PID controller has slightly improved effectiveness in minimizing tie-line power deviation, whereas the 2DOF-PID demonstrates greater resilience and damping capability in frequency regulation across both regions. The findings confirm that the Bee Algorithm-tuned 2DOF-PID controller serves as a robust and effective approach for frequency management in systems primarily reliant on renewable energy sources. Future research should incorporate multi-objective optimization algorithms that concurrently address frequency and tie-line power variations, thereby providing a more equitable control framework for practical Automatic Generation Control (AGC) operations.

31 January 2025 in International Journal of Robotics and Control Systems
Verified
Journal Article
Open access
PDF file
๋O๋Jagraphon obma
๋Jagraphon obma
SASitthisak Audomsi
Sitthisak Audomsi
KAKittipong Ardhan
Kittipong Ardhan
WSWorawat Sa-ngiamvibool
Worawat Sa-ngiamvibool
NCNatpapha Chansom
Natpapha Chansom
Maintaining frequency stability in hybrid renewable-integrated power systems remains a critical challenge due to the inherent variability and uncertainty of photovoltaic–thermal (PV–T) energy sources. Traditional proportional–integral (PI) controllers, optimized using conventional metaheuristic algorithms such as the Whale Optimization Algorithm (WOA), Firefly Algorithm (FA), and Salp Swarm Algorithm (SSA), often suffer from limitations including slow convergence, premature convergence to local optima, and reduced robustness under severe load disturbances. The research contribution is the development and systematic evaluation of a chess algorithm (CA)-based PI controller tuning approach for enhancing load frequency control (LFC) in hybrid PV–T systems. Unlike population-based methods, the CA employs chess-inspired strategic decision-making processes, which improve the search efficiency and the ability to escape local optima in high-dimensional optimization problems. In this study, the proposed CA-based optimization method is applied to a two-area hybrid PV–T power system, where the system is subject to various operating conditions, including solar radiation fluctuations and step load perturbations. The tuning of PI controller parameters is performed using the integral of time-weighted absolute error (ITAE) as the objective function. Simulation results demonstrate that the CA-optimized PI controller achieves superior performance in minimizing overshoot, undershoot, and settling time when compared with controllers optimized by WOA, FA, and SSA. Specifically, the CA approach achieves faster stabilization and lower frequency deviations, highlighting its potential for real-time implementation and enhanced grid reliability. Future work will explore the scalability of the proposed method to multi-area power systems and evaluate its computational efficiency through hardware-in-the-loop validation.

1 February 2025 in International Journal of Electrical and Computer Engineering (IJECE)
Verified
Journal Article
Open access
PDF file
TBTechatat Buranaaudsawakul
Techatat Buranaaudsawakul
KAKittipong Ardhan
Kittipong Ardhan
SASitthisak Audomsi
Sitthisak Audomsi
WSWorawat Sa-ngiamvibool
Worawat Sa-ngiamvibool
RDRattapon Dulyala
Rattapon Dulyala
Load frequency control is necessary for power system management. The power system must maintain a frequency range to ensure power supply stability. System faults and demand fluctuations may cause frequencies to change quickly. System stability and integrity suffer. We are optimizing the two-degree-of-freedom (2-DOF) proportional-integral-derivative (PID) controllers chess algorithm. This article addresses electrical load frequency regulation. We employ classical control theory and current adjustment. It aims for electrical system efficiency and dependability. It checks for errors using integral absolute error (IAE), integral squared error (ISE), integral of time multiply absolute error (ITAE), and integral time squared error (ITSE). Particle swarm algorithm (PSO) compares performance. The IAE of 0.03364, nearly identical to it, shows that chess trumps other algorithms in many scenarios. The chess algorithm's ISE was 0.00035, like PSO's 0.03363. The ISE was 0.00036, indicating PSO's error-reduction capabilities. For the chess algorithm, PSO is 0.07929, and ITAE is 0.07647. This indicates the PSO responds faster to system breakdowns and load changes. Finally, the chess algorithm's ITSE is 0.00072, below the PSO 0.00076. The chess algorithm is better at managing long-term load frequency.

8 December 2025 in Engineering, Technology & Applied Science Research
Verified
Journal Article
Open access
PDF file
SBSomdavee Bhosinak
Somdavee Bhosinak
SASitthisak Audomsi
Sitthisak Audomsi
NANiwat Angkawisittpan
Niwat Angkawisittpan
CPChonlatee Photong
Chonlatee Photong
WSWorawat Sa-ngiamvibool
Worawat Sa-ngiamvibool
This study uses vibration signal analysis to assess and contrast several machine learning models for identifying defects in induction motors. A comprehensive dataset obtained from TDMS-format sensor recordings included seven inter-turn short circuit fault conditions and one normal state. Three experimental settings were investigated: (i) multiclass classification with basic time-domain features, (ii) binary classification using enhanced time and Fast Fourier Transform (FFT) frequency-domain features, and (iii) optimal binary classification using hyperparameter tuning and advanced boosting models. KNN, Random Forest (RF), and ensemble models (XGBoost, LightGBM, CatBoost) were trained and evaluated using accuracy, MSE, RMSE, and R2. The results reveal that while raw time-domain features performed poorly in multiclass tasks (accuracy ~20%), significant gains were obtained utilizing FFT features and binary classification (accuracy up to 80%). Using hyperparameter tuning and gradient boosting techniques, additional enhancements drove the accuracy to 87%, with CatBoost and LightGBM excelling among others. These results highlight the importance of frequency-domain characteristics and model optimization in increasing fault detection dependability. In conclusion, this study helps to encourage the inclusion of intelligent monitoring systems into predictive maintenance pipelines, therefore prolonging the lifetime of industrial equipment and reducing operational downtime.

13 February 2026 in IEEE Access
Verified
Journal Article
Open access
SASitthisak Audomsi
Sitthisak Audomsi
CAChatmongkol Areeyat
Chatmongkol Areeyat
๋O๋Jagraphon obma
๋Jagraphon obma
WSWorawat Sa-ngiamvibool
Worawat Sa-ngiamvibool
The Load Frequency Control (LFC) challenge in multi-source power systems increasingly complicates with the integration of renewable energy, owing to frequent nonlinearities, uncertainties, and disturbances. Conventional controllers such as proportional-integral-derivative (PID) and adaptive PI–1PD frequently exhibit constraints in terms of stability and convergence speed. This study proposes an optimal fuzzy logic two-degree-of-freedom PID controller (Optimal–FL–2DOF–PID) tuned via a metaheuristic chess optimizer (CO), which is a novel optimization algorithm introduced in this study. The performance was evaluated in MATLAB/Simulink under two scenarios: (i) a 5% Step Load Perturbation (SLP) and (ii) a Random Step Load Pattern (RSLP) increment-decrement that effectively mirrors real-world applications. The simulation results demonstrate that the Optimal–FL–2DOF–PID controller surpasses all the comparable controllers. In Scenario 1, the proposed controller attains the lowest objective function—Integral of Timeweighted Absolute Error (ITAE) of 4.6692 corresponding to reductions of 25.31%, 43.05%, and 41.92% relative to 2DOF–PID, PID, and PI–1PD, respectively (and 1.92% relative to the None–optimal–FL–2DOF– PID), overshoot (OS), undershoot (US), settling time (ST) 13–15 s, and tie-line power deviations are likewise reduced. In Scenario 2, using the corresponding optimum parameters from Scenario 1, the Optimal–FL– 2DOF–PID controller achieves ITAE = 395.72, which is lower than the None–optimal–FL–2DOF–PID controller design by 46.52%, and lower than 2DOF–PID, PID, and PI–1PD by 29.73%, 22.19%, and 9.68%, respectively. The frequency–channel ST is 150–180 s, whereas tie-line exchanges settled in the mid–150 s with visibly smoother profiles. These results indicate that Optimal–FL–2DOF–PID provides robust and efficient frequency regulation for multi-area systems under significant uncertainty, supporting deployment in future renewable energy-integrated power systems.