PURPOSE: Primary barriers to application of immune checkpoint inhibitor (ICI) therapy for cancer include severe side effects (such as potentially life threatening pneumonitis [PN]), which can cause the discontinuation of treatment. Predicting which patients may develop PN while on ICI would improve both safety and potential efficacy because treatments could be safely administered for longer or discontinued before severe toxicity. METHODS: Starting from a cohort of 3,351 patients with cancer who received previous ICI therapy at the Vanderbilt University Medical Center, we curated 2,700 contrast chest computed tomography (CT) volumes for 671 patients. Three different pure imaging models predicted the potential for PN using only a single time point before the first ICI dose. RESULTS: The first model used 109 radiomics features only and achieved an AUC of 0.747 (CI, 0.705 to 0.789) with a positive predictive value (PPV) of 0.244 (CI, 0.211 to 0.276) at a sensitivity of 0.553 (CI, 0.485 to 0.621) using mainly features describing the global lung properties. The second model used a convolutional neural network (CNN) on the raw CTs to improve to an AUC of 0.819 (CI, 0.781 to 0.857) with a PPV of 0.244 (CI, 0.203 to 0.284) at a sensitivity of 0.743 (CI, 0.681 to 0.806). The third model combined both radiomics and deep learning but, with an AUC of 0.829 (CI, 0.797 to 0.862) and a PPV of 0.254 (CI, 0.228 to 0.281) at a sensitivity of 0.780 (CI, 0.721 to 0.840), did not show a significant improvement on the CNN-only model. CONCLUSION: This new model suggests the utility of deep learning in PN prediction over traditional pure radiomics and promises better management for patients receiving ICI and the ability to better stratify patients in immunotherapy drug trials.
Background: Quantitative thresholds are helpful to define an abnormal DaT SPECT in patients with suspected nigrostriatal degenerative diseases (NSDD). The optimal DaTQUANT threshold for diagnostic accuracy of DaT SPECT across combined movement and cognitive disorder populations has been previously described. Methods: We established optimal DaTQUANT thresholds that enhance the discrimination between dementia with Lewy bodies (DLB) and non-DLB dementia types, as well as between Parkinsonian syndromes (PS) and conditions not characterized by nigrostriatal degeneration (non-PS). Results: Data from a total of 303 patients were used in this retrospective analysis. Posterior putamen of the more affected hemisphere (MAH) was shown to be an accurate single-variable predictor for both DLB and PS and was comparable to the most accurate multi-variable models. Conclusions: Automated quantification with DaTQUANT can accurately aid in the differentiation of DLB from non-DLB dementias and PS from non-PS. Optimal thresholds for assisting a diagnosis of DLB are striatal binding ratio (SBR) ≤ 0.65, z-score ≤ −2.36, and a percent deviation ≤ −0.54 for the posterior putamen of the MAH. Optimal posterior putamen thresholds for assisting a diagnosis of PS are SBR ≤ 0.92, z-score ≤ −1.53, and a percent deviation ≤ −0.33, which are similar to our previously reported posterior putamen threshold values using a blended patient pool from multiple study populations.
Objective: Dopaminergic imaging is a key biomarker for both the investigation of the biology of Parkinson's disease and related synucleinopathies and the evaluation of potential therapies in clinical trials. This work presents a harmonized approach for quantifying dopaminergic molecular imaging tracers, such as [ 123 I]ioflupane (dopamine transporter scan [DaTscan]) single photon emission computed tomography (SPECT) and [ 18 F]AV133 positron emission tomography (PET), which assess dopaminergic neuronal loss. The proposed method aims to standardize regional outcome measures using a unified scale called Centamines. Methods: The Centamines framework comprises 3 analysis levels. Level 1 defines the Centamine scale based on healthy subject data from [ 123 I]ioflupane SPECT (n = 224). Level 2 uses head‐to‐head data between Tracer X and [ 123 I]ioflupane SPECT to map Tracer X onto the Centamine scale. Level 3 maps additional tracers using prior mappings. A level 2 analysis was performed using [ 123 I]ioflupane SPECT and [ 18 F]AV133 PET data (n = 68) to convert [ 18 F]AV133 PET into Centamines. Results: Level 1 successfully established the Centamine scale using healthy [ 123 I]ioflupane SPECT scans. Level 2 revealed moderate‐strong linear correlations ( R2 = 0.51–0.83) between [ 123 I]ioflupane SPECT and [ 18 F]AV133 PET across 5 brain regions. Mapped Centamine values showed minimal differences between tracers, ranging from 1.5% (post‐commissural putamen) to 3% (caudate). Interpretation: The Centamine scale holds promise for the harmonized quantification of dopaminergic neuronal imaging markers. The Centamine strategy would enable and accelerate clinical trials in Parkinson's disease using dopaminergic imaging outcomes. ANN NEUROL 2026;99:949–963