Rayleigh match data were modeled with the aim of explaining the locations of match midpoints and matching ranges, both in normal trichromats and in subjects with congenital color deficiency. Model parameters included the wavelength of peak sensitivity of cone photopigments, the effective photopigment optical density, and the noise amplitude in the red-green color channel. In order to avoid the suprathreshold, perceptual effects of extreme L:M cone ratios on color vision, selective post-receptoral amplification of cone signals is needed. The associated noise is also amplified and this causes corresponding changes in red-green threshold sensitivity. We propose that the noise amplitude and hence the size of the matching range in normal trichromats relates to the known inter-subject variation in the relative numbers of L and M cones. If this hypothesis can be shown to account for the extremes of the red-green matching range measured in normal trichromats, it is of interest to establish the extent to which it also predicts the unexpected, small matching ranges that are observed in some subjects with red-green color deficiency. A subset of subjects with deutan deficiency that exhibited less common Nagel matches were selected for genetic analysis of their cone pigment genes in order to confirm the type of deficiency, and to predict the corresponding peak wavelength separation (δλmax) of their two, long-wavelength cone pigments. The Rayleigh match model predicted accurately the midpoint and the range for the spectral differences specified by the genes. The prediction also required plausible selection of effective optical density of the cone pigments and noise. The noise needed varied, but the estimates were confined to lie within the limits established from the matching ranges measured in normal trichromats. The model predicts correctly the small matching ranges measured in some deuteranomalous subjects, principally accounted for by a low estimate of noise level in the red-green channel. The model also predicts the “normal” matches made by some subjects that rely on two hybrid genes and therefore exhibit red-green thresholds outside the normal range, typical of mild deuteranomaly.
Normal trichromatic colour vision (CV) is often required as a condition for employment in visually demanding occupations. If this requirement could be enforced using current, colour assessment tests, a significant percentage of subjects with anomalous, congenital trichromacy who can perform the suprathreshold, colour-related tasks encountered in many occupations with the same accuracy as normal trichromats would fail. These applicants would therefore be discriminated against unfairly. One solution to this problem is to produce minimum, justifiable CV requirements that are specific to each occupation. This has been done successfully for commercial aviation (i.e. the flight crew) and for Transport for London train drivers. An alternative approach is to make use of new findings and the statistical outcomes of past practices to produce graded, justifiable CV categories that can be enforced. To achieve this aim, we analysed colour assessment outcomes and quantified severity of CV loss in 1363 subjects. The severity of CV loss was measured in each subject and statistical, pass/fail outcomes established for each of the most commonly used, conventional colour assessment tests and protocols. This evidence and new findings that relate severity of loss to the effective use of colour signals in a number of tasks provide the basis for a new colour grading system based on six categories. A single colour assessment test is needed to establish the applicant's CV category which can range from ‘supernormal’, for the most stringent, colour-demanding tasks, to ‘severe colour deficiency’, when red/green CV is either absent or extremely weak.
Purpose: To evaluate chromatic sensitivity in patients with age-related macular degeneration (AMD) characterized by drusen and reticular pseudodrusen. To investigate whether the severity of color vision loss can distinguish between various stages of AMD and hence be used as an index of progression toward advanced AMD. Methods: Chromatic sensitivity was measured by using the Color Assessment and Diagnosis (CAD) test in asymptomatic individuals with early and intermediate AMD and compared to normative data. All study participants had logMAR visual acuity of 0.3 or better. The CAD thresholds measured in eyes with and without reticular pseudodrusen were also compared and related to central macular thickness (CMT). Student's t-test P values < 0.05 were considered significant. Results: All early- and intermediate-AMD eyes (n = 90) had chromatic sensitivity loss in either RG (red/green) or YB (yellow/blue), or both (P < 0.0001) as compared to age-matched normal subjects. The eyes exhibited a range of CAD thresholds affecting both color mechanisms, but YB color thresholds were in general higher than RG thresholds (P < 0.001). Intermediate-AMD patients exhibited large intersubject variability. In general, eyes with reticular pseudodrusen and eyes with CMT < 200 μm had significantly higher CAD thresholds. Conclusions: The anatomic integrity of cone photoreceptors remains relatively unaffected in early and intermediate stages of AMD. The processing of cone signals in the retina can, however, be heavily disrupted with subsequent loss of both YB and RG chromatic sensitivity. The greatest losses were observed in eyes with reticular pseudodrusen.