Praveen Kumar Praveen Kumar

Dr. Praveen Kumar Praveen Kumar


Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 May 2023 in Sensors
Verified
Journal Article
Open access
PDF file
PHPrashant Hemrajani
Prashant Hemrajani
VDVijaypal Singh Dhaka
Vijaypal Singh Dhaka
Geeta RaniGeeta Rani
Geeta Rani
PKPraveen Kumar Praveen Kumar
Praveen Kumar Praveen Kumar
DBDurga Prasad Bavirisetti
Durga Prasad Bavirisetti
An increasing number of patients and a lack of awareness about obstructive sleep apnea is a point of concern for the healthcare industry. Polysomnography is recommended by health experts to detect obstructive sleep apnea. The patient is paired up with devices that track patterns and activities during their sleep. Polysomnography, being a complex and expensive process, cannot be adopted by the majority of patients. Therefore, an alternative is required. The researchers devised various machine learning algorithms using single lead signals such as electrocardiogram, oxygen saturation, etc., for the detection of obstructive sleep apnea. These methods have low accuracy, less reliability, and high computation time. Thus, the authors introduced two different paradigms for the detection of obstructive sleep apnea. The first is MobileNet V1, and the other is the convergence of MobileNet V1 with two separate recurrent neural networks, Long-Short Term Memory and Gated Recurrent Unit. They evaluate the efficacy of their proposed method using authentic medical cases from the PhysioNet Apnea-Electrocardiogram database. The model MobileNet V1 achieves an accuracy of 89.5%, a convergence of MobileNet V1 with LSTM achieves an accuracy of 90%, and a convergence of MobileNet V1 with GRU achieves an accuracy of 90.29%. The obtained results prove the supremacy of the proposed approach in comparison to the state-of-the-art methods. To showcase the implementation of devised methods in a real-life scenario, the authors design a wearable device that monitors ECG signals and classifies them into apnea and normal. The device employs a security mechanism to transmit the ECG signals securely over the cloud with the consent of patients.

10 May 2021 in IEEE Sensors Journal
Verified
Journal Article
Closed access
PKPraveen Kumar Praveen Kumar
Praveen Kumar Praveen Kumar
RCRahul Kumar Chaurasiya
Rahul Kumar Chaurasiya
SVShrish Verma
Shrish Verma
G R SinhaG R Sinha
G R Sinha
The main objective of brain-computer interface (BCI)-based asynchronous system is to detect user’s intentional control (IC) and non-control (NC) states. In IC state, users are constantly adapting to the BCI system and making selections, whereas in NC state, users ignore to focus on the BCI system. Most of the current methods for IC or NC state detection are based on thresholding. However, choosing a suitable threshold is often time-consuming. Moreover, the chosen threshold may be insufficient over a long period of time due to the variability of EEG signals. This article proposes an asynchronous P300-based row-column paradigm (RCP) system for home appliances control. The proposed system is able to detect IC and NC states of the subject. A novel 2×3 matrix consisting of home appliances (such as light, fan, mobile device, door, television, and electric heater) has been proposed as an RCP. For stimulation, technical paper & video clip were shown on a computer screen to the users. Step-wise linear discriminant analysis (SWLDA) classifier was employed in the proposed thresholding-free asynchronous-BCI system to distinguishes between user IC and NC states. In the proposed experiment, fourteen healthy and nine paralyzed persons have participated as volunteer subjects. The synchronous mode average classification accuracy of 92.44% and 89.33% was achieved for healthy and paralyzed participants, respectively. Thereafter, the average asynchronous mode accuracy of 94.28% and 92.11% with very less false activation rate (FARs) of 0.15/min and 0.162/min was achieved for healthy and paralyzed participants, respectively. As an application, the developed P300-based speller was used to control home appliances by issuing different commands. The experimental results validated the effectiveness of the proposed method and presents future direction to use the system for paralyzed patients.

6 October 2020 in Electronics Letters
Verified
Journal Article
Open access
PDF file
PKPraveen Kumar Praveen Kumar
Praveen Kumar Praveen Kumar
RCR. Chaurasiya
R. Chaurasiya
SVS. Verma
S. Verma
P300 speller‐based brain–computer interface (BCI) is an immediate correspondence between the human brain and computer that depends on the translation of mind reactions produced by the stimulus of a subject utilising the P300 speller. No muscle movements are required for this communication. As a P300 paradigm, a novel 2 × 3 matrix consisting of visual home appliances is proposed, which helps disabled people ease their lives by accessing mobile, light, fan, door, television, electric heater etc. In most of the current P300‐based BCIs, 5–15 trials work better and the low information transfer rate (ITR) is a major issue in its adaptation in real‐time. The objective of this Letter is to improve accuracy as well as an ITR for real‐time home appliance control applications. To address this, the authors proposed a single trial weighted ensemble of compact convolution neural network and obtained an ITR of 46.45 bits per minute and an average target appliance accuracy of 93.22% for the BCI‐based home environment system. The experimental findings confirmed the feasibility of the proposed method and thus can provide guidance for future use of the system for paralysed patients.

10 December 2025 in Frontiers in Robotics and AI
Verified
Journal Article
Open access
PDF file
RMRohit Mittal
Rohit Mittal
NANikunj Agarwal
Nikunj Agarwal
MDManan Dubey
Manan Dubey
VPVibhakar Pathak
Vibhakar Pathak
PKPraveen Kumar Praveen Kumar
Praveen Kumar Praveen Kumar
EZEster Zumpano
Ester Zumpano
Parkinson’s Disease is a progressively advancing neurological condition. Its severity is evaluated by utilizing the Hoehn and Yahr staging scale. Such assessments may be inconsistent, are more time-consuming, and expensive for patients. To address these shortcomings, this article introduces a machine learning-based gait classification system to assist doctors in identifying the stages of Parkinson’s disease. This study utilizes two open-access benchmark datasets from PhysioNet and Figshare to assess ground reaction force collected from patients diagnosed with Parkinson’s Disease. This study presents experiments conducted using machine learning algorithms namely Decision Tree, Random Forest, Extreme Gradient Boost, and Light Gradient Boosting Machine classification algorithms to predict severity of Parkinson’s Disease. Among all the four algorithms, Light Gradient Boosting Machine classification algorithm have proven its supremacy. It gave an accuracy of 98.25%, Precision of 98.35%, Recall of 98.25%, and F1 Score of 98% for dataset 1. The performance of the algorithm slightly declines on dataset 2. It reports accuracy of 85%, Precision of 95%, Recall of 85% and F1 Score of 89% for dataset 2. Furthermore, this study used Explainable Artificial Intelligence to display the LightGBM classifier’s classification pathways for Parkinson’s disease severity prediction using Hoehn and Yahr staging on the scale from 0 to 5. This is helps the health experts in decision making. This work provides automated assistance to doctors for the rapid screening of Parkinson’s disease patients based on disease severity. This work leaves a scope for integrating wearable sensors and developing real-time monitoring system for screening of Parkinson’s Disease patients.

26 February 2014 in Arkivoc
Verified
Journal Article
Open access
PRP. Venkat Reddy
P. Venkat Reddy
MSMohammad Saquib
Mohammad Saquib
NMNripendra N. Mishra
Nripendra N. Mishra
PKPraveen Kumar Praveen Kumar
Praveen Kumar Praveen Kumar
ASArun K. Shaw
Arun K. Shaw

29 December 2025 in International Journal of Information Technology
Verified
Journal Article
Closed access
PDF file
SASarita
Sarita
PKPraveen Kumar Praveen Kumar
Praveen Kumar Praveen Kumar
VDVijaypal Singh Dhaka
Vijaypal Singh Dhaka
NJNayani Jindal
Nayani Jindal