Purpose: The purpose of this study was to evaluate three different methods of attachment of continuous loop suspensory cortical preparation of all soft tissue central quad tendon grafts compared to a bone block control for anterior cruciate ligament reconstruction on construct displacement and load to failure. Methods: Thirty‐two cadaveric central quadriceps tendon (CQT) specimens were harvested, using three clinical techniques for graft fixation: cortical button alone (BTB EB), BTB cortical button with rip‐stop suture (BTB RS), and continuous loop cortical button (BTB CL). A control group was also included that consisted of a bone block secured within testing clamps (BTB CON). Specimens were preloaded to 150 N. Tendons were then cyclically loaded between 50 N and 250 N for 1,000 cycles at .5 Hz. Displacement was measured at the point of fixation of the CQT after the 150 N preload, 250 N initial load and every 100th cycle. The specimens were loaded to failure after 1,000 cycles. Results: There was a significant increase in displacement from .32 ± .56 mm for the BTB CON to 1.91 ± 1.13 mm for the BTB RS ( P = .014) and 3.85 ± 2.32 mm for the BTB CL condition ( P = .023). There was no significant increase in displacement for BTB EB ( P = .182). Failure occurred for all of the BTB CL and 62.5% of the BTB EB specimens within the first 50 cycles. Twenty‐five percent of the BTB CON specimens and 12.5% BTB RS failed at ∼400 and 500 cycles, respectively. Similar failure loads were observed for the BTB CON and the BTB RS (446.4 ± 151.46 N vs 505.74 ± 131.41 N; P = .99) Failure testing was not feasible for the BTB CL and BTB EB preparation methods. Conclusion: In response to cyclic loading, the three all‐soft tissue suspensory conditions experienced significantly greater displacement compared to the bone block controls. None of the soft‐tissue conditions appeared superior when compared to each other. Clinical Relevance: It remains unknown which method of soft‐tissue suspensory provides optimal fixation. As these autografts become more common, it is essential to evaluate which fixation methods provide superior outcomes
10 February 2014 in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
The purpose of this work was to develop and validate a finite element model of the distal radius to simulate impact loading. Eight-node hexahedral meshes of the bone and impactor components were created. Three separate impact events were simulated by altering the impact velocity assigned to the model projectile (pre-fracture, crack and fracture). Impact forces and maximum and minimum principal strains were calculated and used in the validation process by comparing with previously collected experimental data. Three measures of mesh quality (Jacobians, aspect ratios and orthogonality) and four validation methods (validation metric, error assessment, fracture comparisons and ensemble averages) assessed the model. The element Jacobians, aspect ratios and orthogonality measures ranged from 0.08 to 12, 1.1 to 26 and −70° to 80°, respectively. The force and strain validation metric ranged from 0.10 to 0.54 and 0.35 to 0.67, respectively. The estimated peak axial force was found to be a maximum of 28.5% greater than the experimental (crack) force, and all forces fell within ±2 standard deviation of the mean experimental fracture forces. The predicted strains were found to differ by a mean of 33% across all impact events, and the model was found to accurately predict the location and severity of bone damage. Overall, the model presented here is a valid representation of the distal radius subjected to impact.
25 January 2017 in Knee Surgery, Sports Traumatology, Arthroscopy