Irene Hernández Martínez

Mrs. Irene Hernández Martínez

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 April 2025 in Diagnostics
Verified
Journal Article
Open access
PDF file
Andrea BordonadoAndrea Bordonado
Andrea Bordonado
JMJavier Marco-Lledó
Javier Marco-Lledó
PNPilar Nieto-Gil
Pilar Nieto-Gil
LZLuz Marina Zuluaga
Luz Marina Zuluaga
PRPaloma López Ros
Paloma López Ros
JGJonatan García-Campos
Jonatan García-Campos
Background/Objectives: Due to poor perfusion, diabetic foot ulcers (DFUs) create hypoxic environments, and their chronicity represents a negative factor in wound healing. Transcutaneous oxygen pressure (TcPO2) is a non-invasive method that provides information on oxygen supply to microvascular circulation, useful for determining the severity and progression of peripheral arterial disease (PAD) as well as potentially predicting DFU healing. However, the current literature does not provide strong support for the use of TcPO2 as an independent predictive tool. Methods: This protocol aims to systematically review the available evidence according to PRISMA (2020) guidelines, registered with the International Prospective Register of Systematic Reviews (registration number: CRD42024505907). The following databases will be used: Cochrane Library, EMBASE, Ovid Medline, PubMed, and Web of Science. Additionally, a manual search will be conducted through the references of the included articles. Results: The systematic review will summarize the current evidence on the prognostic value of TcPO2 in DFU healing, identifying gaps in knowledge and potential areas for future research. Conclusions: The findings of this study may clarify the prognostic value of TcPO2 in DFU healing, which could ultimately facilitate clinical management, decision-making, patient care, and potentially reduce treatment costs.

9 January 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Vicente Jesús León-MuñozVicente Jesús León-Muñoz
Vicente Jesús León-Muñoz
JHJosé Hurtado-Avilés
José Hurtado-Avilés
Joaquin Moya-AngelerJoaquin Moya-Angeler
Joaquin Moya-Angeler
GVGregorio Valero-Cifuentes
Gregorio Valero-Cifuentes
IMIrene Hernández Martínez
Irene Hernández Martínez
FSFernando Santonja-Medina
Fernando Santonja-Medina
To establish classifications and to obtain pre- and post-operative information on patient-specific alignments, it is necessary to measure different angular values accurately and precisely, mainly on weight-bearing, full-length anteroposterior X-rays of the lower limbs (LLRs). This study evaluated angular measurements’ validity and absolute reliability on LLRs with a self-developed, computer-aided measurement system (TraumaMeter v.873). Eight independent observers measured the preoperative mechanical hip-knee-ankle (mHKA) angle of 52 lower extremities (26 cases) in a blinded fashion on three occasions separated by two weeks. We obtained an intra-observer mean bias error (MBE) of 0.40°, a standard deviation (SD) of 0.11°, and a 95% confidence interval (CI) of 0.37°–0.43°. We also obtained an inter-observer MBE of 0.49°, an SD of 0.15°, and a 95% C of 0.45°–0.53°. The intra-observer MBE for the measurement pair between the second and the first measurement round (T2T1) was 0.43°, the SD was 0.13°, and the 95% CI was 0.39°–0.47°; the MBE between the third and the second round (T3T2) was 0.37°, with an SD of 0.10° and a 95% CI of 0.34°–0.40°; and the MBE between the third and the first round (T3T1) was 0.40°, with an SD of 0.10° and a 95% CI of 0.37°–0.43°. The interobserver MBE for the first round of measurements was 0.52°, with an SD of 0.16° and a 95% CI of 0.48°–0.56°; the MBE for the second round was 0.50°, with an SD of 0.15° and a 95% CI of 0.46°–0.54°; and the MBE for the third round was 0.46°, with an SD of 0.14° and a 95% CI of 0.42°–0.50°. There were no statistically significant differences in the inter-observer errors for the three tests. In the case of the intra-observer analysis, there were differences between T2T1 and between T3T2, but these differences were minimal, with no overlaps in the lower or upper values, respectively, of the confidence intervals. These results led us to conclude that the TraumaMeter v.873 software extension for measuring lower-limb angles in LLRs is an accurate tool with low intra- and inter-observer variability.