Roman Ruff

Mr. Roman Ruff


Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2007
Verified
Conference Paper
Closed access
KHKlaus-Peter Hoffmann
Klaus-Peter Hoffmann
RRRoman Ruff
Roman Ruff
In this paper a new generation of dry electrodes for ECG-recording purposes is presented. These electrodes are flexible, biocompatible, biostable and perform a dry signal acquisition without the use of any electrolyte gel or adhesive. Thereby no skin preparation is needed. The material properties allow integration into textiles to form intelligent clothes for long-term monitoring duties. The electrodes can be washed together with the carrier textiles and provide a very good wearing comfort resulting in wide acceptance by the patients. The Department Medical Engineering and Neuroprosthetics of the Fraunhofer Institute for Biomedical Engineering developed these electrodes mainly to process the Electrocardiogram, however, in first tests they proved their capability even for other biosignal requirements like surface-EMG. In either case the signal quality of the dry electrodes is comparable to commercial Ag/AgCl gel-electrodes.

8 September 2017 in Current Directions in Biomedical Engineering
Verified
Journal Article
Open access
PDF file
SWSebastian Winkler
Sebastian Winkler
JEJan Edelmann
Jan Edelmann
CWChristine Welsch
Christine Welsch
RRRoman Ruff
Roman Ruff
Recent advancements in implant technology include increasing application of electronic systems in the human body. Hermetic encapsulation of electronic components is necessary, specific implant functions and body environments must be considered. Additional functions such as wireless communication systems require specialized technical solutions for the encapsulation. In this paper 3 different implant strategies based on the material groups silicone, ceramics and titanium alloys are evaluated. With the background of a specific application the requirements for the encapsulation are defined and include the implementation of electrical feedthroughs, wireless communication and wireless energy transfer as well as biomedical specifications such as hermetic sealing, mechanical stability and biocompatibility. The encapsulations are manufactured and qualified experimentally.

1 January 2013 in Biomedical Engineering / Biomedizinische Technik
Verified
Journal Article
Closed access
KHKlaus-Peter Hoffmann
Klaus-Peter Hoffmann
RRRoman Ruff
Roman Ruff
MKMatthias Kirsch
Matthias Kirsch
This article is a methodical report on the generation of reproducible changes in brain activity in a murine model. Somatosensory evoked potentials (SEP) are used to generate synchronized cortical activity. After electrical stimulation of mice forelimbs, the potentials were recorded with a flexible thin-film polyimide electrode structure directly from the cortex. Every registration included a simultaneous recording from both hemispheres that repeated four times to reproduce and compare the results. The SEPs in the murine model were shown to generate a very stable signal. The latency of the second positive wave (P2 wave) ranged between 16 and 19 ms, and the N1-P2 amplitude ranged between 39 and 48 mu V. In addition, the temperature distribution of the cortex was acquired using infrared thermography. Surface cortical temperature changed during electrical stimulation without a clear hemispheric correlation. These initial results could be a step toward a better understanding of the different synchronized cortical activities and basic methods of evaluation of various mathematical algorithms to detect them

1 August 2010
Verified
Conference Paper
Closed access
RRRoman Ruff
Roman Ruff
WPWigand Poppendieck
Wigand Poppendieck
AGAlexander Gail
Alexander Gail
SWStephanie Westendorff
Stephanie Westendorff
MRMichael Russold
Michael Russold
KHKlaus-Peter Hoffmann
Klaus-Peter Hoffmann
The acquisition of myoelectric signals from the Musculus deltoideus of a rhesus monkey is described. Such signals are aimed to be used as control signal for an active myoelectric hand prosthesis. For recording, implantable flexible, polyimide-based multi-site microelectrodes were placed epimysially on the muscle. EMG signals were recorded during voluntary goal-directed movements of the arm, and analyzed with respect to signal amplitude and frequency.

1 February 2018 in Biosensors
Verified
Journal Article
Open access
PDF file
PGPaul Glogener
Paul Glogener
MKMichael Krause
Michael Krause
JKJens Katzer
Jens Katzer
MSMarkus A. Schubert
Markus A. Schubert
MBMario Birkholz
Mario Birkholz
KHKlaus P. Hoffmann
Klaus P. Hoffmann
A microelectronic biosensor was subjected to in vivo exposure by implanting it in the vicinity of m. trapezii (Trapezius muscle) from cattle. The implant is intended for the continuous monitoring of glucose levels, and the study aimed at evaluating the biostability of exposed semiconductor surfaces. The sensor chip was a microelectromechanical system (MEMS) prepared using 0.25 µm complementary metal–oxide–semiconductor CMOS/BiCMOS technology. Sensing is based on the principle of affinity viscometry with a sensoric assay, which is separated by a semipermeable membrane from the tissue. Outer dimensions of the otherwise hermetically sealed biosensor system were 39 × 49 × 16 mm. The test system was implanted into cattle in a subcutaneous position without running it. After 17 months, the device was explanted and analyzed by comparing it with unexposed chips and systems. Investigations focused on the MEMS chip using SEM, TEM, and elemental analysis by EDX mapping. The sensor chip turned out to be uncorroded and no diminishing of the topmost passivation layer could be determined, which contrasts remarkably with previous results on CMOS biosensors. The negligible corrosive attack is understood to be a side effect of the semipermeable membrane separating the assay from the tissue. It is concluded that the separation has enabled a prolonged biostability of the chip, which will be of relevance for biosensor implants in general.

1 March 2017 in Current Directions in Biomedical Engineering
Verified
Journal Article
Open access
PDF file
ABAlexander Brensing
Alexander Brensing
RRRoman Ruff
Roman Ruff
BFBenjamin Fischer
Benjamin Fischer
SWSascha L. Wien
Sascha L. Wien
KHKlaus-Peter Hoffmann
Klaus-Peter Hoffmann
The usability of flexible electrodes in moving environment is limited due to different mechanical characteristics of their metallic and polymeric components. To achieve structure compatible electrodes, all used materials need to have similar Young’s moduli as the surrounding tissue. This paper describes the characterization of macroscopic as well as miniaturized electrodes entirely made out of modified silicone (PDMS). Electrochemical, mechanical, biological, optical, and applicative methods were used. It could be shown, that PDMS electrodes are capable to be used for recording electrocardiograms with similar form and amplitude as with standard electrodes.