Shuai Huang

Ms. Shuai Huang


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 October 2024 in Remote Sensing
Verified
Journal Article
Open access
PDF file
HWHongyu Wu
Hongyu Wu
Guanzhou ChenGuanzhou Chen
Guanzhou Chen
YBYang Bai
Yang Bai
YPYing Peng
Ying Peng
QBQianqian Ba
Qianqian Ba
FFFuyu Feng
Fuyu Feng
On-orbit geometric calibration is key to improving the geometric positioning accuracy of high-resolution optical remote sensing satellite data. Grouped calibration with geometric consistency (GCGC) is proposed in this paper for the Jilin1-KF01B satellite, which is the world’s first satellite capable of providing 150-km swath width and 0.5-m resolution data. To ensure the geometric accuracy of high-resolution image data, the GCGC method conducts grouped calibration of the time delay integration charge-coupled device (TDI CCD). Each group independently calibrates the exterior orientation elements to address the multi-time synchronization issues between imaging processing system (IPS). An additional inter-chip geometric positioning consistency constraint is used to enhance geometric positioning consistency in the overlapping areas between adjacent CCDs. By combining image simulation techniques associated with spectral bands, the calibrated panchromatic data are used to generate simulated multispectral reference band image as control data, thereby enhancing the geometric alignment consistency between panchromatic and multispectral data. Experimental results show that the average seamless stitching accuracy of the basic products after calibration is better than 0.6 pixels, the positioning accuracy without ground control points(GCPs) is better than 20 m, the band-to-band registration accuracy is better than 0.3 pixels, the average geometric alignment consistency between panchromatic and multispectral data are better than 0.25 multispectral pixels, the geometric accuracy with GCPs is better than 2.1 m, and the geometric alignment consistency accuracy of multi-temporal data are better than 2 m. The GCGC method significantly improves the quality of image data from the Jilin1-KF01B satellite and provide important references and practical experience for the geometric calibration of other large-swath high-resolution remote sensing satellites.

4 July 2026 in Remote Sensing
Verified
Journal Article
Open access
PDF file
XYXiaojie Yang
Xiaojie Yang
QLQiuyan Liu
Qiuyan Liu
SYSong Yang
Song Yang
YBYang Bai
Yang Bai
SHShuai Huang
Shuai Huang
WWWeibin Wang
Weibin Wang
On-orbit absolute radiometric calibration tracks sensor radiometric degradation and ensures accuracy for quantitative applications. Low-cost commercial satellites lack expensive on-board calibration systems, and traditional alternative methods cannot achieve automated, reliable calibration for large sensor fleets with low resource consumption. Pseudo-invariant calibration sites require no ground instruments, but commercial satellites’ heavy imaging schedules hinder frequent PICS observations. The Jilin-1 constellation is a large commercial constellation composed of satellites carrying multispectral imagers with resolution better than 1 m, and it has no on-board calibration system. Thus, an automated calibration method applicable to numerous imagers is needed, one that requires widely available clear-sky ground targets. Using MCD43A2 and MCD12Q1 products, we generate calibration region vectors to transfer the MODIS radiometric reference to Jilin-1. A look-up table (LUT) is constructed for the input parameters of the MODTRAN model. Calibration pixels and model input parameters are then extracted from Jilin-1 imagery using the region vectors, the LUT is interpolated to obtain the at-aperture radiance for each pixel and band, and on-orbit absolute radiometric calibration coefficients are calculated. The proposed method requires no ground-based synchronous experiments, achieves a high level of automation, and does not consume commercial imaging resources. The site calibration validation based on RadCalNet for the JL1GF02F PMS1 sensor shows that the maximum relative difference in the method across all bands is less than 4%.

17 December 2024 in Remote Sensing
Verified
Journal Article
Open access
PDF file
JLJiangpeng Li
Jiangpeng Li
YBYang Bai
Yang Bai
SHShuai Huang
Shuai Huang
SYSong Yang
Song Yang
YSYingshan Sun
Yingshan Sun
XYXiaojie Yang
Xiaojie Yang
Color distortion is a common issue in Jilin-1 KF01 series satellite imagery, a phenomenon caused by the instability of the sensor during the imaging process. In this paper, we propose a data-driven method to correct color distortion in Jilin-1 KF01 imagery. Our method involves three key aspects: color-distortion simulation, model design, and post-processing refinement. First, we investigate the causes of color distortion and propose algorithms to simulate this phenomenon. By superimposing simulated color-distortion patterns onto clean images, we construct color-distortion datasets comprising a large number of paired images (distorted–clean) for model training. Next, we analyze the principles behind a denoising model and explore its feasibility for color-distortion correction. Based on this analysis, we train the denoising model from scratch using the color-distortion datasets and successfully adapt it to the task of color-distortion correction in Jilin-1 KF01 imagery. Finally, we propose a novel post-processing algorithm to remove boundary artifacts caused by block-wise image processing, ensuring consistency and quality across the entire image. Experimental results show that the proposed method significantly eliminates color distortion and enhances the radiometric quality of Jilin-1 KF01 series satellite imagery, offering a solution for improving its usability in remote sensing applications.

2 November 2024 in Remote Sensing
Verified
Journal Article
Open access
PDF file
SHShuai Huang
Shuai Huang
SYSong Yang
Song Yang
YBYang Bai
Yang Bai
YSYingshan Sun
Yingshan Sun
BZBo Zou
Bo Zou
XYXiaojie Yang
Xiaojie Yang
The optical remote sensors carried by the Jilin-1 KF02 series satellites have an imaging resolution better than 0.5 m and a width of 150 km. There are radiometric problems, such as stripe noise, vignetting, and inter-slice chromatic aberration, in their raw images. In this paper, a relative radiometric correction method based on temperature normalization is proposed for the response characteristics of sensors and the structural characteristics of optical splicing of Jilin-1 KF02 series satellites cameras. Firstly, a model of temperature effect on sensor output is established to correct the variation of sensor response output digital number (DN) caused by temperature variation during imaging process, and the image is normalized to a uniform temperature reference. Then, the horizontal stripe noise of the image is eliminated by using the sensor scan line and dark pixel information, and the vertical stripe noise of the image is eliminated by using the method of on-orbit histogram statistics. Finally, the method of superposition compensation is used to correct the vignetting area at the edge of the image due to the lack of energy information received by the sensor so as to ensure the consistency of the image in color and image quality. The proposed method is verified by Jilin-1 KF02A on-orbit images. Experimental results show that the image response is uniform, the color is consistent, the average Streak Metrics (SM) is better than 0.1%, Root-Mean-Square Deviation of the Mean Line (RA) and Generalized Noise (GN) are better than 2%, Relative Average Spectral Error (RASE) and Relative Average Spectral Error (ERGAS) are greatly improved, which are better than 5% and 13, respectively, and the relative radiation quality is obviously improved after relative radiation correction.