This paper focuses on the effect of tunneling-induced ground deformation on the response of jointed cast iron and ductile iron pipelines that (i) cross the settlement profile perpendicular to the tunnel centerline and (ii) connect through 90° tees with a pipeline parallel to the tunnel centerline. The modeling involves two-dimensional finite element analyses that account for coupled forces both parallel and perpendicular to the pipeline, and incorporates the results of large-scale laboratory tests to characterize the joints. Pipeline response is quantified with respect to joint rotation and pullout at various leakage levels as well as the allowable tensile strain. The paper describes soil displacements induced by a 6.1 m (20 ft.) diameter tunnel in clay and sand. Joint rotations and maximum tensile strains for pipelines in sand exceed those in clay by up to three for the same geometric conditions. Cast iron pipelines crossing the tunnel centerline are most vulnerable to leakage from joint rotation; ductile iron pipelines have sufficient capacity against joint leakage in all cases studied. Cast iron pipelines that connect with 90° tees are highly vulnerable to leakage from pullout due to lateral soil movement. Guidance is provided for risk assessment, design, and utility operations.
1 February 2016 in Journal of Pipeline Systems Engineering and Practice
The performance of segmental pipelines under large ground deformation is strongly influenced by the axial pullout and compressive load capacity of their joints, as well as by the limits on joint rotation during permanent and transient ground deformation. Although ductile iron (DI) pipelines with push-on joints are commonly used in water distribution systems, experimental data and numerical simulation related to their performance under large ground movements are lacking. This paper reports on a series of specially designed four-point bending experiments and finite-element (FE) simulations to characterize 150-mm (6-in.) diameter DI push-on joints. The results were used to develop a relationship between rotation and metal binding as a function of axial pullout, as well as to determine the magnitudes of rotation and moment that initiate joint leakage. FE simulations were performed to investigate the deformation associated with joint leakage. Uniaxial tension and one-dimensional compression tests were performed on the elastomeric gasket and fitted with hyperelastic strain energy approximations to characterize behavior under extreme loading. Numerical models demonstrate joint leakage to be independent of load path, and that a unique pressure boundary predicts leakage for many combinations of deformation.
1 September 2020 in Journal of Geotechnical and Geoenvironmental Engineering
Dense granular columns (DGCs) are generally known to mitigate the liquefaction hazard through a combination of (1) installation-induced ground densification, (2) enhanced drainage, and (3) shear reinforcement. However, the relative contribution of these mitigation mechanisms remains poorly understood. A recent case history of successful embankment performance on a liquefiable site treated with DGCs that had relatively low area replacement ratios ( ) (where drainage is not notably enhanced) suggested that shear reinforcement and installation-induced ground densification may be the two dominant mitigation mechanisms provided by DGCs. In this paper, we present a series of four dynamic centrifuge experiments designed and conducted to test this hypothesis under controlled conditions. Consistent with case history observations and supporting our initial working hypothesis, densification combined with shear reinforcement was shown to be primarily responsible for limiting the embankment’s seismic deformations. Additional drainage led to minor improvements in terms of embankment settlement, while increasing its permanent lateral displacement. The results suggest that the combined effects of and ratio of maximum shear modulus of the DGCs to that of the surrounding soil ( ) can play a key role in the distribution of stress between DGCs and soil prior to shaking and the extent of softening and strain accumulation in various layers during shaking. For example, it was observed that densification of the liquefiable sand layer around DGCs shifted the generation of larger excess pore pressures to greater depths compared to the DGC-treated test without densification. This led to a base isolation effect that reduced accelerations, degree of softening, and accumulation of shear and volumetric strains at shallower depths, producing a notably improved performance for the soil–embankment system even when the DGC’s drainage capacity was inhibited. These observations were attributed to the reinforcement effect of DGCs, the simultaneous reduction in due to densification, and a more even transfer of the embankment load onto the soil–column matrix, increasing the stiffness and strength and reducing shear strains in the shallower and looser layer. The presented experimental results point to the importance of accounting for pre- and postinstallation soil density and stiffness in relation to DGCs, confining pressure distributions, kinematic constraints, and activity of various mitigation mechanisms when evaluating the potential influence of DGCs on seismic demand, liquefaction triggering, and deformations near embankment structures.
1 March 2019 in Journal of Geotechnical and Geoenvironmental Engineering
Cured-in-place linings (CIPLs) are flexible fiber-reinforced polymer linings used to rehabilitate aging pipelines in situ. They also can strengthen utilities against transient and permanent ground deformation caused by earthquakes, thus providing added value through seismic retrofitting. This paper presents the results of full-scale fault rupture tests to characterize the debonding, axial elongation, and bending performance of pipelines with circumferential cracks and weak joints strengthened with CIPLs and subjected to abrupt ground deformation. The results of finite-element simulations were compared with the experimental fault rupture response of jointed pipelines with and without CIPL reinforcement. The results of a numerical model that accounts for debonding between the lining and pipe as Mode II fracture propagation were in good agreement with full-scale fault rupture test results. Recommendations are made for applying the modeling and experimental results for in situ strengthening of underground utilities against earthquakes and other sources of permanent ground deformation.
1 November 2019 in Journal of Pipeline Systems Engineering and Practice
In responding to the need for improved technologies to accommodate permanent ground deformation imposed by earthquakes, landslides, and other sources, a new family of segmented pipelines has emerged employing joints that displace axially and deflect before locking up and restraining further movement. Other than employing finite-element modeling, there is no existing procedure allowing practicing engineers to efficiently evaluate displacements and strains that develop along segmented pipelines consistent with those of continuous pipelines at equivalent levels of potential ground movement. A methodology is presented that allows continuous and segmented pipelines of any defined material in the elastic range to be evaluated consistently using a single set of equations for block ground deformations moving parallel to the longitudinal pipe axis. The equations reduce to previously recognized solutions for continuous pipelines as the segmented pipe joints reach their allowable displacement. Results show how the hybrid-segmented pipelines have lower axial strains than continuous pipes for equivalent levels of block deformation. The proposed model provides a fundamental basis for engineering design selection of continuous and segmented pipelines in hazard-prone regions.