The fourth-generation mitral transcatheter edge-to-edge repair (M-TEER) device introduced an improved clip deployment sequence, independent leaflet grasping, and 2 wider clip sizes to tailor the treatment of patients with mitral regurgitation (MR) for a broad range of anatomies. The 30-day safety and effectiveness of the fourth-generation M-TEER device were previously demonstrated. The aim of this study was to evaluate 1-year outcomes in a contemporary, real-world cohort of subjects treated with the MitraClip G4 system. EXPAND G4 is an ongoing prospective, multicenter, international, single-arm study that enrolled subjects with primary and secondary MR. One-year outcomes included MR severity (echocardiographic core laboratory assessed), heart failure hospitalization, all-cause mortality, functional capacity (NYHA functional class), and quality of life (Kansas City Cardiomyopathy Questionnaire). A total of 1,164 subjects underwent M-TEER from 2020 to 2022. At 1 year, there was a durable reduction in MR to mild or less in 92.6% and to none or trace in 44.2% (P < 0.0001 vs baseline). Few subjects had major adverse events through 1 year (<2% for myocardial infarction, surgical reintervention, or single-leaflet device attachment). The 1-year Kaplan-Meier estimates for all-cause mortality and heart failure hospitalization were 12.3% and 16.9%. Significant improvements in functional capacity (NYHA functional class I or II in 82%; P < 0.0001 vs baseline) and quality of life (18.5-point Kansas City Cardiomyopathy Questionnaire overall summary score improvement; P < 0.0001) were observed. M-TEER with the fourth-generation M-TEER device was safe and effective at 1 year, with durable reductions in MR severity to ≤1+ in more than 90% of patients and concomitant improvements in functional status and quality of life.
Background: No study has so far compared Amulet with the new Watchman FLX in terms of residual left atrial appendage (LAA) patency or clinical outcomes in patients undergoing percutaneous LAA closure. Methods: In the investigator-initiated SWISS APERO trial (Comparison of Amulet Versus Watchman/FLX Device in Patients Undergoing Left Atrial Appendage Closure), patients undergoing LAA closure were randomly assigned (1:1) open label to receive Amulet or Watchman 2.5 or FLX (Watchman) across 8 European centers. The primary end point was the composite of justified crossover to a nonrandomized device during LAA closure procedure or residual LAA patency detected by cardiac computed tomography angiography (CCTA) at 45 days. The secondary end points included procedural complications, device-related thrombus, peridevice leak at transesophageal echocardiography, and clinical outcomes at 45 days. Results: Between June 2018 and May 2021, 221 patients were randomly assigned to Amulet (111 [50.2%]) or Watchman (110 [49.8%]), of whom 25 (22.7%) patients included before October 2019 received Watchman 2.5, and 85 (77.3%) patients received Watchman FLX. The primary end point was assessable in 205 (92.8%) patients and occurred in 71 (67.6%) patients receiving Amulet and 70 (70.0%) patients receiving Watchman, respectively (risk ratio, 0.97 [95% CI, 0.80–1.16]; P =0.713). A single justified crossover occurred in a patient with Amulet who fulfilled LAA patency criteria at 45-day CCTA. Major procedure-related complications occurred more frequently in the Amulet group (9.0% versus 2.7%; P =0.047) because of more frequent bleeding (7.2% versus 1.8%). At 45 days, the peridevice leak rate at transesophageal echocardiography was higher with Watchman than with Amulet (27.5% versus 13.7%, P =0.020), albeit none was major (ie, >5 mm), whereas device-related thrombus was detected in 1 (0.9%) patient with Amulet and 3 (3.0%) patients with Watchman at CCTA and in 2 (2.1%) and 5 (5.5%) patients at transesophageal echocardiography, respectively. Clinical outcomes at 45 days did not differ between the groups. Conclusions: Amulet was not associated with a lower rate of the composite of crossover or residual LAA patency compared with Watchman at 45-day CCTA. Amulet, however, was associated with lower peridevice leak rates at transesophageal echocardiography, higher procedural complications, and similar clinical outcomes at 45 days compared with Watchman. The clinical relevance of CCTA-detected LAA patency requires further investigation. Registration: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT03399851.
26 June 2023 in JACC: Cardiovascular Interventions
The fourth-generation MitraClip G4 System builds on the previous NTR/XTR system with additional wider clip sizes (NTW and XTW), an independent grasping feature, and an improved clip deployment sequence. The primary objective of this study was to assess the safety and performance of the MitraClip G4 System within a contemporary real-world setting. EXPAND G4 is a prospective, multicenter, international, single-arm, postapproval study that enrolled patients with primary (degenerative) mitral regurgitation (MR) and secondary (functional) MR at 60 centers. Follow-up of the full cohort has been conducted through 30 days. Echocardiograms were analyzed by an echocardiography core laboratory. Study outcomes included MR severity, functional capacity measured by NYHA functional class, quality of life measured using the Kansas City Cardiomyopathy Questionnaire, major adverse event rates, and all-cause mortality. In EXPAND G4, 1,141 subjects with primary MR and secondary MR were treated from March 2021 to February 2022. Implantation and acute procedural success rates were 98.0% and 96.2%, respectively, with a mean of 1.4 ± 0.6 clips implanted per subject. MR was significantly reduced at 30 days compared with baseline (98% achieved MR ≤ 2+, and 91% achieved MR ≤ 1+; P < 0.0001). Functional capacity and quality of life were substantially improved, with 83% of patients achieving NYHA functional class I or II. Likewise, an 18-point improvement was observed in Kansas City Cardiomyopathy Questionnaire summary scores compared with baseline. The composite major adverse event rate was 2.7%, and the all-cause death rate was 1.3% at 30 days. This study demonstrates for the first time the effectiveness and safety of MitraClip G4 System at 30 days in a cohort of >1,000 patients with MR in a contemporary, real-world setting.
16 September 2022 in JACC: Cardiovascular Interventions
Aims : In the last decade, transcatheter aortic valve (TAV) replacement determined a paradigm shift in the treatment of patients with severe symptomatic aortic stenosis. Data on long-term TAV performance are still limited. We sought to evaluate the clinical and haemodynamic outcomes of the CoreValve self-expandable valve up to 8-year follow-up (FU). Methods and results : Nine hundred and ninety inoperable or high-risk patients were treated with the CoreValve TAV in eight Italian Centres from June 2007 to December 2011. The median FU was 4.4 years (interquartile range 1.4–6.7 years). Longest FU reached 11 years. A total of 728 died within 8-year FU (78.3% mortality from Kaplan–Meier curve analysis). A significant functional improvement was observed in the majority of patients and maintained over time, with 79.3% of surviving patients still classified New York Heart Association class ≤ II at 8 years. Echocardiographic data showed that the mean transprosthetic aortic gradient remained substantially unchanged (9 ± 4 mmHg at discharge, 9 ± 5 mmHg at 8 years, P = 0.495). The rate of Grade 0/1 paravalvular leak was consistent during FU with no significant change from post-procedure to FU ≥5 years in paired analysis (P = 0.164). Structural valve deterioration (SVD) and late bioprosthetic valve failure (BVF) were defined according to a modification of the 2017 EAPCI/ESC/EACTS criteria. In cumulative incidence functions at 8 years, moderate and severe SVD were 3.0% [95% confidence interval (CI) 2.1–4.3%] and 1.6% (95% CI 0.6–3.9%), respectively, while late BVF was 2.5% (95% CI 1.2–5%). Conclusion : While TAVs are questioned about long-term performance and durability, the results of the present research provide reassuring 8-year evidence on the CoreValve first-generation self-expandable bioprosthesis.