Daniel Anheuer

Mr. Daniel Anheuer


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 October 2024 in Sensors
Verified
Journal Article
Open access
PDF file
DADaniel Anheuer
Daniel Anheuer
BKBrid Karacan
Brid Karacan
LHLara Herzog
Lara Herzog
NWNora Weigel
Nora Weigel
SMSilja Meyer-Nieberg
Silja Meyer-Nieberg
CKCornelia Küsel
Cornelia Küsel
To better cope with stress in emergencies, emergency personnel undergo virtual reality (VR) stress training. Such training typically includes visual, auditory and sometimes tactile impressions, whereas olfactory stimuli are mostly neglected. This concept paper therefore examines whether odors might be beneficial for further enhancing the experience of presence and immersion into a simulated environment. The aim is to demonstrate the benefits of VR civilian stress training for emergency personnel and to investigate the role of odors as stressors by manipulating the degree of perceived psychophysiological stress via olfactory impressions. Moreover, the current paper presents the development and validation of a convenient and portable fragrance dosing system that allows personalized odor presentation in VR. The presented system can transport reproducible small quantities of an air-fragrance mixture close to the human nose using piezoelectric stainless steel micropumps. The results of the fluidic system validation indicate that the micropump is suitable for releasing odors close to the nose with constant amounts of odor presentation. Furthermore, the theoretical background and the planned experimental design of VR stress training, including odor presentation via olfactory VR technology, are elucidated.

31 May 2023 in Actuators
Verified
Journal Article
Open access
PDF file
MRMartin Richter
Martin Richter
DADaniel Anheuer
Daniel Anheuer
AWAxel Wille
Axel Wille
YCYuecel Congar
Yuecel Congar
MWMartin Wackerle
Martin Wackerle
Fraunhofer EMFT’s research and manufacturing portfolio includes piezoelectrically actuated silicon micro diaphragm pumps with passive flap valves. Research and development in the field of microfluidics have been dedicated for many years to the use of micropumps for generating positive and negative pressures, as well as delivering various media. However, for some applications, only small amounts of fluid need to be pumped, compressed, or evacuated, and until now, only macroscopic pumps with high power consumption have been able to achieve the necessary flow rate and pressure, especially for compressible media such as air. To address these requirements, one potential approach is to use a multistage of high-performing micropumps optimized to negative pressure. In this paper, we present several possible ways to cascade piezoelectric silicon micropumps with passive flap valves to achieve these stringent requirements. Initially, simulations are conducted to generate negative pressures with different cascading methods. The first multistage option assumes pressure equalization over the piezo-actuator by the upstream pump, while for the second case, the actuator diaphragm operates against atmospheric pressure. Subsequently, measurement results for the generation of negative gas pressures down to −82.1 kPa relative to atmospheric pressure (19.2 kPa absolute) with a multistage of three micropumps are presented. This research enables further miniaturization of many applications with high-performance requirements for micropumps, achievable with these multistage systems.

16 October 2024 in Micromachines
Verified
Journal Article
Open access
PDF file
DADaniel Anheuer
Daniel Anheuer
JSJohannes Schwarz
Johannes Schwarz
PDPatrick Débera
Patrick Débera
KHKlaus Heinrich
Klaus Heinrich
CKChristoph Kutter
Christoph Kutter
MRMartin Richter
Martin Richter
To improve the performance of valves in relation to the leakage rate, a comprehensive evaluation of the valve characteristics and behavior during pressure exposure is important. Often, these low gas flow rates below 0.1 cm3/min cannot be accurately measured with conventional flow sensors. This paper presents a small and low-cost test rig for measuring gas leakage rates accurately, even far below 0.1 cm3/min, with the pressure decay method. These leakage flows are substantiated with a flow model, where we demonstrate the feasibility of modeling those gas flows with an extended Navier–Stokes framework to obtain more accurate theoretical predictions. As expected, the comparison to the experimental results proves that the classical Navier–Stokes system is unsuitable for modeling Knudsen flows. Hence, self-diffusion of gas, a wall-slip boundary condition, and an effective mean free path model were introduced in a physically evident manner. In terms of the calculated mass flow, while self-diffusion and slip boundary conditions explain deviations from the classical Navier–Stokes equation for Knudsen numbers already smaller than 1, the effective mean free path model has an effect, especially when Kn > 1. For simplified conditions, an analytical solution was presented and compared to the results of an OpenFOAM CFD-solver for flow rates through more complex gap-flow geometries of the flap valve. Hereby, acceptable deviations between 10% and 20% were observed. A comparison with measurement results was carried out. The reproducibility of the measurement method was verified by comparing multiple measurements of one silicon microvalve sample to a state-of-the-art flow sensor. Three geometrically similar passive silicon microvalves were measured with air overpressure decreasing from 15 kPa relative to atmospheric pressure. Maximum gas volume flowing in a blocking direction of 1–26 µL/min with high reproducibility and marginal noise were observed.

8 October 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
DADaniel Anheuer
Daniel Anheuer
BKBrid Karacan
Brid Karacan
LHLara Herzog
Lara Herzog
NWNora Weigel
Nora Weigel
SMSilja Meyer-Nieberg
Silja Meyer-Nieberg
CKCornelia Küsel
Cornelia Küsel
To better cope with stress in emergencies, emergency personnel undergo virtual reality (VR) stress trainings. Such trainings typically include visual, auditory and sometimes tactile impressions, whereas olfactory stimuli are mostly neglected. This concept paper therefore examines whether odors might be beneficial for further enhancing the experience of presence and immersion into a simulated environment. The aim is to demonstrate the benefits of VR civilian stress trainings for emergency personnel and to investigate the role of odors as stressors by manipulating the degree of perceived psychophysiological stress via olfactory impressions. Moreover, the current paper presents the development and validation of a convenient and portable fragrance dosing system that allows personalized odor presentation in VR. The presented system can transport reproducible small quantities of an air-fragrance mixture close to the human nose using piezoelectric stainless steel micropumps. The results of the fluidic system validation indicate that the micropump is suitable to release odors close to the nose with constant amounts of odor presentation. Furthermore, the theoretical background and the planned experimental design of VR stress training including odor presentation via olfactory VR technology is elucidated.

10 December 2025 in Journal of Micromechanics and Microengineering
Verified
Journal Article
Open access
DADaniel Anheuer
Daniel Anheuer
HLHenry Leistner
Henry Leistner
SSShebeeb Sirajudeen
Shebeeb Sirajudeen
MWMartin Wackerle
Martin Wackerle
AKAgnes Knorr
Agnes Knorr
MRMartin Richter
Martin Richter
In microfluidic systems, valves are used to control the flow of fluid and enable different functions like mixing, switching or flow regulation. A wide variety of valve types and operating mecha-nisms have been developed to fulfil the diverse requirements of different applications. Silicon as the fabrication material for many micro-electromechanical systems provides numerous ad-vantages compared to alternative materials. Key features such as biocompatibility, high precision manufacturing with accurate geometries and mono-crystalline material properties without me-chanical degradation make silicon an excellent material for microvalves. In this paper, we present the design, numerical mechanical simulation, manufacturing and fluidical characterization with air of normally closed passive silicon microvalves. Three different valve geometries are evaluated regarding their fluidical performance to determine the suitability for gas applications as part of silicon micropumps. Two single clamped cantilever valves and one double clamped membrane valve are characterized in terms of opening behaviour, pressure dependent flowrate, pressure drop and leakage. Two of the three valves' optical evaluation of the flap and diaphragm deflection correlate closely to the mechanical simulation. The fluidic measurements demonstrate repro-ducibility and repeatability and confirm the suitability of the valves for different applications with demanding requirements.