Context: Identification of impaired balance as a risk factor for lower extremity injury regardless of injury history has led to subsequent investigation of variables that may adversely affect balance in healthy individuals. Objectives: To investigate the relationship among core and lower extremity muscle function, foot posture, and balance. Design: Descriptive laboratory study. Setting: Musculoskeletal injury biomechanics laboratory. Patients or Other Participants: A total of 108 individuals (40 men, 68 women; age = 22.8 ± 4.7 years, height = 168.5 ± 10.4 cm, mass = 69.9 ± 13.3 kg) participated in the study. Main Outcome Measure(s): Core endurance was assessed during 1 time-to-failure trial, and isometric hip and ankle strength were assessed using a handheld dynamometer and isokinetic dynamometer, respectively. Foot structure was quantified using the digital photographic measurement method. Single-limb–stance time to boundary was assessed using a force plate during an eyes-closed condition. Hierarchical multiple regression analyses were performed to predict balance using lower extremity strength, foot posture, and core endurance. Results: Foot posture (β = −0.22, P = .03) and ankle-inversion strength (β = −0.29, P = .006) predicted mediolateral balance. Increasing arch posture and ankle-inversion strength were associated with decreased mediolateral single-limb–stance balance. Conclusions: Increasing arch height was associated with decreased mediolateral control of single-limb stance. The relationship between time to boundary and injury risk, however, has not been explored. Therefore, the relationship between increasing arch height and injury due to postural instability cannot be determined from this study. If authors of future prospective studies identify a relationship between decreased time to boundary and increased injury risk, foot structure may be an important variable to assess during preparticipation physical examinations. The relationship between increasing ankle-inversion strength and decreased balance may require additional study to further elucidate the relationship between ankle strength and balance.
Context: Although abnormal foot posture long has been associated with lower extremity injury risk, the evidence is equivocal. Poor intertester reliability of traditional foot measures might contribute to the inconsistency. Objectives: To investigate the validity and reliability of a digital photographic measurement method (DPMM) technology, the reliability of DPMM-quantified foot measures, and the concurrent validity of the DPMM with clinical-measurement methods (CMMs) and to report descriptive data for DPMM measures with moderate to high intratester and intertester reliability. Design: Descriptive laboratory study. Setting: Biomechanics research laboratory. Patients or Other Participants: A total of 159 people participated in 3 groups. Twenty-eight people (11 men, 17 women; age = 25 ± 5 years, height = 1.71 ± 0.10 m, mass = 77.6 ± 17.3 kg) were recruited for investigation of intratester and intertester reliability of the DPMM technology; 20 (10 men, 10 women; age = 24 ± 2 years, height = 1.71 ± 0.09 m, mass = 76 ± 16 kg) for investigation of DPMM and CMM reliability and concurrent validity; and 111 (42 men, 69 women; age = 22.8 ± 4.7 years, height = 168.5 ± 10.4 cm, mass = 69.8 ± 13.3 kg) for development of a descriptive data set of the DPMM foot measurements with moderate to high intratester and intertester reliabilities. Intervention(s): The dimensions of 10 model rectangles and the 28 participants' feet were measured, and DPMM foot posture was measured in the 111 participants. Two clinicians assessed the DPMM and CMM foot measures of the 20 participants. Main Outcome Measure(s): Validity and reliability were evaluated using mean absolute and percentage errors and intraclass correlation coefficients. Descriptive data were computed from the DPMM foot posture measures. Results: The DPMM technology intratester and intertester reliability intraclass correlation coefficients were 1.0 for each tester and variable. Mean absolute errors were equal to or less than 0.2 mm for the bottom and right-side variables and 0.1° for the calculated angle variable. Mean percentage errors between the DPMM and criterion reference values were equal to or less than 0.4%. Intratester and intertester reliabilities of DPMM-computed structural measures of arch and navicular indices were moderate to high (>0.78), and concurrent validity was moderate to strong. Conclusions: The DPMM is a valid and reliable clinical and research tool for quantifying foot structure. The DPMM and the descriptive data might be used to define groups in future studies in which the relationship between foot posture and function or injury risk is investigated.
Context: : Patellofemoral pain (PFP) is typically exacerbated by repetitive activities that load the patellofemoral joint, such as running. Understanding the mediating effects of changes in pain in individuals with PFP might inform injury progression, rehabilitation, or both.Objective: : To investigate the effects of changing pain on muscular strength and running biomechanics in those with PFP.Design: : Crossover study.Setting: : University research laboratory.Patients or Other Participants: : Seventeen participants (10 men, 7 women) with PFP.Intervention(s): : Each participant completed knee pain-reducing and pain-inducing protocols in random order. The pain-reducing protocol consisted of 15 minutes of transcutaneous electric nerve stimulation (TENS) around the patella. The pain-inducing protocol was sets of 20 repeated single-legged squats (RSLS). Participants completed RSLS sets until either their pain was within at least 1 cm of their pain during an exhaustive run or they reached 10 sets.Main Outcome Measure(s): : Pain, isometric hip and trunk strength, and running mechanics were assessed before and after the protocols. Dependent variables were pain, normalized strength (abduction, extension, external rotation, lateral trunk flexion), and peak lower extremity kinematics and kinetics in all planes. Pain scores were analyzed using a Friedman test. Strength and mechanical variables were analyzed using repeated-measures analyses of variance. The α level was set at P < .05.Results: : Pain was decreased after the TENS (pretest: 3.10 ± 1.95, posttest: 1.89 ± 2.33) and increased after the RSLS (baseline: 3.10 ± 1.95, posttest: 4.38 ± 2.40) protocols (each P < .05). The RSLS protocol resulted in a decrease in hip-extension strength (baseline: 0.355 ± 0.08 kg/kg, posttest: 0.309 ± 0.09 kg/kg; P < .001). Peak plantar-flexion angle was decreased after RSLS (baseline: −13.97° ± 6.41°, posttest: −12.84° ± 6.45°; P = .003). Peak hip-extension (pretest: −2.31 ± 0.46) and hip-abduction (pretest: −2.02 ± 0.35) moments decreased after both the TENS (extension: −2.15 ± 0.48 Nm/kg, P = .015; abduction: −1.91 ± 0.33 Nm/kg, P = .015) and RSLS (extension: −2.18 ± 0.52 Nm/kg, P = .003; abduction: −1.87 ± 0.36 Nm/kg, P = .039) protocols.Conclusions: : This study presents a novel and effective method of increasing pain in persons with PFP. Functionally increased pain after RSLS coincides with reduced hip-extensor muscle strength and decreased plantar-flexion angle during running. The TENS treatment decreased pain during running in those with PFP but failed to influence strength. Hip moments were reduced by both protocols, which may demonstrate that acute increases or decreases in pain cause runners to change their mechanics.
Context: Foot-orthosis (FO) intervention to prevent and treat numerous lower extremity injuries is widely accepted clinically. However, the results of quantitative gait analyses have been equivocal. The foot models used, participants receiving intervention, and orthoses used might contribute to the variability. Objective: To investigate the effect of a custom-molded FO intervention on multisegment medial foot kinematics during walking in participants with low-mobile foot posture. Design: Crossover study. Setting: University biomechanics and ergonomics laboratory. Patients or Other Participants: Sixteen participants with low-mobile foot posture (7 men, 9 women) were assigned randomly to 1 of 2 FO groups. Intervention(s): After a 2-week period to break in the FOs, individuals participated in a gait analysis that consisted of 5 successful walking trials (1.3 to 1.4 m/s) during no-FO and FO conditions. Main Outcome Measure(s): Three-dimensional displacements during 4 subphases of stance (loading response, mid-stance, terminal stance, preswing) were computed for each multisegment foot model articulation. Results: Repeated-measures analyses of variance (ANOVAs) revealed that rearfoot complex dorsiflexion displacement during midstance was greater in the FO than the no-FO condition (F1,14 = 5.24, P = .04, partial η2 = 0.27). Terminal stance repeated-measures ANOVA results revealed insert-by-insert condition interactions for the first metatarsophalangeal joint complex (F1,14 = 7.87, P = .01, partial η2 = 0.36). However, additional follow-up analysis did not reveal differences between the no-FO and FO conditions for the balanced traditional orthosis (F1,14 = 4.32, P = .08, partial η2 = 0.38) or full-contact orthosis (F1,14 = 4.10, P = .08, partial η2 = 0.37). Conclusions: Greater rearfoot complex dorsiflexion during midstance associated with FO intervention may represent improved foot kinematics in people with low-mobile foot postures. Furthermore, FO intervention might partially correct dys-functional kinematic patterns associated with low-mobile foot postures.