Madhan Kumar Vasudevan

Dr. Madhan Kumar Vasudevan


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

19 April 2023
Verified
Conference Paper
Open access
MVMadhan Kumar Vasudevan
Madhan Kumar Vasudevan
SZShu Zhong
Shu Zhong
JKJan Kučera
Jan Kučera
DCDesiree Cho
Desiree Cho
MOMarianna Obrist
Marianna Obrist

25 September 2020 in The International Journal of Medical Robotics and Computer Assisted Surgery
Verified
Journal Article
Open access
PDF file
MVMadhan Kumar Vasudevan
Madhan Kumar Vasudevan
JIJoseph H. R. Isaac
Joseph H. R. Isaac
VSVenkatraman Sadanand
Venkatraman Sadanand
MMManivannan Muniyandi
Manivannan Muniyandi
Background: Training surgeons to use surgical robots are becoming part of surgical training curricula. We propose a novel method of training fine‐motor skills such as Microscopic Selection Task (MST) for robot‐assisted surgery using virtual reality (VR) with objective quantification of performance. We also introduce vibrotactile feedback (VTFB) to study its impact on training performance.Methods: We use a VR‐based environment to perform MST with varying degrees of difficulties. Using a well‐known human–computer interaction paradigm and incorporating VTFB, we quantify the performance: speed, precision and accuracy.Results: MST with VTFB showed statistically significant improvement in performance metrics leading to faster completion of MST with higher precision and accuracy compared to that without VTFB.Discussion: The addition of VTFB to VR‐based training for robot‐assisted surgeries may improve performance outcomes in real robotic surgery. VTFB, along with proposed performance metrics, can be used in training curricula for robot‐assisted surgeries.

11 May 2024
Verified
Conference Paper
Open access
ZSZhouyang Shen
Zhouyang Shen
ZMZak Morgan
Zak Morgan
MVMadhan Kumar Vasudevan
Madhan Kumar Vasudevan
MOMarianna Obrist
Marianna Obrist
DPDiego Martinez Plasencia
Diego Martinez Plasencia
Multi-point STM offers a great range of parameters (i.e., drawing frequency, number of points) to produce different tactile sensations. However, existing studies offer limited insight on the effects of these parameters, and ignore their effect on the physical stimuli delivered, limiting effective haptic design. We propose a two-stage model to predict response to multi-point STM. The first stage predicts physical stimulus properties with 7.8% error, while the second stage predicts mean and spread of perceived intensity with 8.0 % and 8.8% error. We report 3 studies conducted to derive this model: one to characterize physical stimuli, another one measuring user perceptual thresholds, and a third one measuring user’s perceptual response to multi-point STM. Besides, we characterize 4 effects that influence device performance, confirm if previous effects reported are due to physical or perceptual effects (or both) and derive recommendations for manufacturers, haptic designers and HCI researchers.

17 February 2020 in Somatosensory & Motor Research
Verified
Journal Article
Closed access
MVMadhan Kumar Vasudevan
Madhan Kumar Vasudevan
VSVenkatraman Sadanand
Venkatraman Sadanand
MMManivannan Muniyandi
Manivannan Muniyandi
MSMandayam A. Srinivasan
Mandayam A. Srinivasan
The Pacinian Corpuscle (PC) is the most sensitive mechanoreceptor in the human body found in clusters of two or three. We extended our previous model of an isolated-PC to a cluster-PC focussing on relative spike delay and displacement threshold for understanding how the stimulus location is coded. In our model, two PCs with Gaussian overlapping receptive fields are arranged beneath the skin model. For a spatiotemporal stimulus (vibration), the model response is proposed to be a time-division multiplexing of responses from two PCs within the cluster. While the spike rate characteristics and pole-zero plot of cluster-PC model show similarities with the isolated-PC model, the frequency response shows ripples after 1 kHz as the distance (d) between the PCs increases. The stimulus location (ψ) and d influence the relative spike delay and the displacement threshold, but not the spike rate. The novel contributions from our model include prediction of (i) relative spike delay for various d, stimulus frequency (f), and ψ, (ii) spike rate characteristics for varying f, and (iii) displacement threshold curve as a function of frequency for various d. Although the physiological validation of the novel predictions is impractical, we have validated the relative spike delay and the displacement threshold curves with experimental data in the literature.

19 April 2023
Verified
Conference Paper
Open access
PCPatricia Cornelio
Patricia Cornelio
SHStephen Hughes
Stephen Hughes
OGOrestis Georgiou
Orestis Georgiou
WFWilliam Frier
William Frier
MMMartin Maunsbach
Martin Maunsbach
MOMarianna Obrist
Marianna Obrist