Xiaohong Zhang

Prof. Dr. Xiaohong Zhang


Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 January 2020 in International Journal of Radiation Biology
Verified
Journal Article
Closed access
XZXiaohong Zhang
Xiaohong Zhang
XXXueshuang Xing
Xueshuang Xing
HLHuiwen Liu
Huiwen Liu
JFJundong Feng
Jundong Feng
MTMengxin Tian
Mengxin Tian
HZHaiqian Zhang
Haiqian Zhang
Purpose: To study whether radiation-induced bleeding in the bone marrow induced iron accumulation, and subsequently caused ferroptosis in granulocyte-macrophage hematopoietic progenitor cells. Materials and methods: Male mice were subjected to different doses (0, 4, 8, or 10 Gy) of gamma radiation from a 137Cs source. The changes in iron metabolism or ferroptosis-related parameters of irradiated bone marrow were accessed with biochemical, histopathological, and antibody methods. Hematocytes were detected with a hematology analyzer. The counts of granulocyte-macrophage hematopoietic progenitor cells were measured with the granulocyte-macrophage colony-forming unit. Results: Iron accumulation occurred in the bone marrow, which caused by radiation-induced hemorrhage. The iron accumulation triggered an iron regulatory protein-ferroportin 1 axis to increase serum iron levels. Using LDN193189, radiation-induced iron accumulation was demonstrated to decrease white blood cell counts at least partly through a decrease in the counts of granulocyte-macrophage hematopoietic progenitor cells. The reduction in the counts of granulocyte-macrophage hematopoietic progenitor cells was subsequently demonstrated to attribute to ferroptosis with the use of ferroptosis inhibitors and through the detection of ferroptosis related-parameters. The survival rate of irradiated mice was improved using Ferrostatin-1 or LDN193189. Conclusions: These findings suggest that radiation-induced hemorrhage in the bone marrow causes ferroptosis in granulocyte-macrophage hematopoietic progenitor cells, and anti-ferroptosis has the potential to be a radioprotective strategy to ameliorate radiation-induced hematopoietic injury.

31 January 2021 in International Journal of Radiation Biology
Verified
Journal Article
Closed access
XZXiaohong Zhang
Xiaohong Zhang
MTMengxin Tian
Mengxin Tian
XLXin Li
Xin Li
CZChunyan Zheng
Chunyan Zheng
AWAilian Wang
Ailian Wang
HZHaiqian Zhang
Haiqian Zhang
Baicalein (an anti-ferroptosis drug) was recently reported to synergistically improve the survival rate of mice following a high dose of total body irradiation with anti-apoptosis and anti-necropto...

4 January 2022 in International Journal of Radiation Biology
Verified
Journal Article
Closed access
XZXiaohong Zhang
Xiaohong Zhang
XLXin Li
Xin Li
CZChunyan Zheng
Chunyan Zheng
CYChunzhi Yang
Chunzhi Yang
RZRui Zhang
Rui Zhang
HZHaiqian Zhang
Haiqian Zhang
Ferroptosis is an iron-dependent form of regulated cell death, driven by excessive lipid peroxidation and/or inactivation/depletion of protective molecules against lipid peroxidation. Ionizing radi...

2 April 2019 in Nanomaterials
Verified
Journal Article
Open access
PDF file
SCShuquan Chang
Shuquan Chang
XWXian Wu
Xian Wu
JLJianzhang Lan
Jianzhang Lan
ZLZheng Li
Zheng Li
XZXiaohong Zhang
Xiaohong Zhang
HZHaiqian Zhang
Haiqian Zhang
Quantum dots (QDs) have attracted great attention due to their unique optical properties. High fluorescence efficiency is very important for their practical application. In this study, we report a simple and efficient strategy to enhance the photoluminescence of water-dispersed thiol-capped QDs using γ-radiation. Three kinds of QDs with different surface ligands and cores (MPA-CdTe, MPA-CdSe and Cys-CdTe) were fabricated and irradiated by high-energy γ-ray in an aqueous solution. Their photoluminescence intensities were significantly enhanced after irradiation, which were closely related to the radiation dose and the structure of QDs. The positions of the fluorescence emission peaks did not shift obviously after irradiation. The mechanism of photoluminescence enhancement was discussed based on the results of photoluminescence (PL) spectra, UV-visible light absorption (UV-vis) spectra, transmission electron microscope (TEM), X-ray diffraction (XRD) patterns, Fourier transform infrared (FT-IR) spectra and X-ray photoelectron spectroscopy (XPS). This method can be employed to uniformly treat large batches of QDs at room temperature and without other chemicals.

5 February 2024 in Radiation Oncology
Verified
Journal Article
Open access
PDF file
BLBenzhe Liang
Benzhe Liang
GGGuanzhong Gong
Guanzhong Gong
YTYing Tong
Ying Tong
LWLizhen Wang
Lizhen Wang
YSYa Su
Ya Su
YYYong Yin
Yong Yin
Purpose: This study seeks to examine the influence of the heartbeat on the position, volume, and shape of the heart and its substructures during various breathing states. The findings of this study will serve as a valuable reference for dose-volume evaluation of the heart and its substructures in radiotherapy for treating thoracic tumors. Methods: Twenty-three healthy volunteers were enrolled in this study, and cine four-dimensional magnetic resonance images were acquired during periods of end-inspiration breath holding (EIBH), end-expiration breath holding (EEBH), and deep end-inspiration breath holding (DIBH). The MR images were used to delineate the heart and its substructures, including the heart, pericardium, left ventricle (LV), left ventricular myocardium, right ventricle (RV), right ventricular myocardium (RVM), ventricular septum (VS), atrial septum (AS), proximal and middle portions of the left anterior descending branch (pmLAD), and proximal portion of the left circumflex coronary branch (pLCX). The changes in each structure with heartbeat were compared among different respiratory states. Results: Compared with EIBH, EEBH increased the volume of the heart and its substructures by 0.25–3.66%, while the average Dice similarity coefficient (DSC) increased by − 0.25 to 8.7%; however, the differences were not statistically significant. Conversely, the VS decreased by 0.89 mm in the left–right (LR) direction, and the displacement of the RV in the anterior–posterior (AP) direction significantly decreased by 0.76 mm (p < 0.05). Compared with EIBH and EEBH, the average volume of the heart and its substructures decreased by 3.08–17.57% and 4.09–20.43%, respectively, during DIBH. Accordingly, statistically significant differences (p < 0.05) were observed in the volume of the heart, pericardium, LV, RV, RVM, and AS. The average DSC increased by 0–37.04% and − 2.6 to 32.14%, respectively, with statistically significant differences (p < 0.05) found in the right ventricular myocardium and interatrial septum. Furthermore, the displacements under DIBH decreased in the three directions (i.e.,− 1.73 to 3.47 mm and − 0.36 to 2.51 mm). In this regard, the AP displacement of the heart, LV, RV, RVM, LR direction, LV, RV, and AS showed statistically significant differences (p < 0.05). The Hausdorff distance (HD) of the heart and its substructures under the three breathing states are all greater than 11 mm. Conclusion: The variations in the displacement and shape alterations of the heart and its substructures during cardiac motion under various respiratory states are significant. When assessing the dose-volume index of the heart and its substructures during radiotherapy for thoracic tumors, it is essential to account for the combined impacts of cardiac motion and respiration.

14 July 2021 in Materials
Verified
Journal Article
Open access
PDF file
WZWei Zhang
Wei Zhang
KWKaikai Wang
Kaikai Wang
YZYufeng Zeng
Yufeng Zeng
XHXiaodan Hu
Xiaodan Hu
XZXiaohong Zhang
Xiaohong Zhang
HZHaiqian Zhang
Haiqian Zhang
The diffusion of ferric ions is an important challenge to limit the application of Fricke gel dosimeters in accurate three-dimensional dose verification of modern radiotherapy. In this work, low-diffusion Fricke gel dosimeters, with a core-shell structure based on spatial confinement, were constructed by utilizing microdroplet ultrarapid freezing and coating technology. Polydimethylsiloxane (PDMS), with its excellent hydrophobicity, was coated on the surface of the pellets. The concentration gradient of the ferric ion was realized through shielding half of a Co-60 photon beam field size, and ion diffusion was measured by both ultraviolet-visible spectrophotometry and magnetic resonance imaging. No diffusion occurred between the core-shell pellets, even at 96 h after irradiation, and the diffusion length at the irradiation boundary was limited to the diameter (2–3 mm) of the pellets. Furthermore, Monte Carlo calculations were conducted to study dosimetric properties of the core-shell dosimeter, which indicated that a PDMS shell hardly affected the performance of the dosimeter.