Shwetabh Verma

Dr. Shwetabh Verma


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 February 2015 in Eye and Vision
Verified
Journal Article
Open access
PDF file
SASamuel Arba-Mosquera
Samuel Arba-Mosquera
SVShwetabh Verma
Shwetabh Verma
Colm McAlindenColm McAlinden
Colm McAlinden
The human eye is an asymmetric optical system and the real cornea is not a rotationally symmetrical volume. Each optical element in the eye has its own optical and neural axes. Defining the optimum center for laser ablation is difficult with many available approaches. We explain the various centration approaches (based on these reference axes) in refractive surgery and review their clinical outcomes. The line-of-sight (LOS) (the line joining the entrance pupil center with the fixation point) is often the recommended reference axis for representing wavefront aberrations of the whole eye (derived from the definition of chief ray in geometrical optics); however pupil centration can be unstable and change with the pupil size. The corneal vertex (CV) represents a stable preferable morphologic reference which is the best approximate for alignment to the visual axis. However, the corneal light reflex can be considered as non-constant, but dependent on the direction of gaze of the eye with respect to the light source. A compromise between the pupil and CV centered ablations is seen in the form of an asymmetric offset where the manifest refraction is referenced to the CV while the higher order aberrations are referenced to the pupil center. There is a need for a flexible choice of centration in excimer laser systems to design customized and non-customized treatments optimally.

1 September 2015 in American Journal of Ophthalmology
Verified
Journal Article
Open access
MLMichiel H.A. Luger
Michiel H.A. Luger
CMColm McAlinden
Colm McAlinden
Phillip BuckhurstPhillip Buckhurst
Phillip Buckhurst
James S. WolffsohnJames S. Wolffsohn
James S. Wolffsohn
SVShwetabh Verma
Shwetabh Verma
SASamuel Arba-Mosquera
Samuel Arba-Mosquera
To evaluate distance and near image quality after hybrid bi-aspheric multifocal central presbyLASIK treatments. Consecutive case series. Sixty-four eyes of 32 patients consecutively treated with central presbyLASIK were assessed. The mean age of the patients was 51 ± 3 years with a mean spherical equivalent refraction of -1.08 ± 2.62 diopters (D) and mean astigmatism of 0.52 ± 0.42 D. Monocular corrected distance visual acuity (CDVA), corrected near visual acuity (CNVA), and distance corrected near visual acuity (DCNVA) of nondominant eyes; binocular uncorrected distance visual acuity (UDVA); uncorrected intermediate visual acuity (UIVA); distance corrected intermediate visual acuity (DCIVA); and uncorrected near visual acuity (UNVA) were assessed pre- and postoperatively. Subjective quality of vision and near vision was assessed using the 10-item Rasch-scaled Quality of Vision and Near Activity Visual Questionnaire, respectively. At 1 year postoperatively, 93% of patients achieved 20/20 or better binocular UDVA; 90% and 97% of patients had J2 or better UNVA and UIVA, respectively; 7% lost 2 Snellen lines of CDVA; Strehl ratio reduced by ∼-4% ± 14%. Defocus curves revealed a loss of half a Snellen line at best focus, with no change for intermediate vergence (-1.25 D) and a mean gain of 2 lines for near vergence (-3 D). Presbyopic treatment using a hybrid bi-aspheric micro-monovision ablation profile is safe and efficacious. The postoperative outcomes indicate improvements in binocular vision at far, intermediate, and near distances with improved contrast sensitivity. A 19% retreatment rate should be considered to increase satisfaction levels, besides a 3% reversal rate.

21 June 2018 in PLOS ONE
Verified
Journal Article
Open access
PDF file
RMRichard N McNeely
Richard N McNeely
SMSalissou Moutari
Salissou Moutari
SASamuel Arba-Mosquera
Samuel Arba-Mosquera
SVShwetabh Verma
Shwetabh Verma
JMJonathan E Moore
Jonathan E Moore
To highlight the potential shortcomings associated with the current use Rasch analysis for validation of ophthalmic questionnaires, and to present an alternative application of Rasch analysis to derive insights specific to the cohort of patients under investigation. An alternative application of Rasch analysis was used to investigate the quality of vision (QoV) for a cohort of 481 patients. Patients received multifocal intraocular lenses and completed a QoV questionnaire one and twelve months post-operatively. The rating scale variant of the polytomous Rasch model was utilized. The parameters of the model were estimated using the joint maximum likelihood estimation. Analysis was performed on data at both post-operative assessments, and the outcomes were compared. The distribution of the location of symptoms altered between assessments with the most annoyed patients completely differing. One month post-operatively, the most prevalent symptom was starbursts compared to glare at twelve months. The visual discomfort from the most annoyed patients is substantially higher at twelve months. The current most advocated approach for validating questionnaires using Rasch analysis found that the questionnaire was “Rasch-valid” one month post-operatively and “Rasch-invalid” twelve months post-operatively. The proposed alternative application of Rasch analysis to questionnaires can be used as an effective decision support tool at population and individual level. At population level, this new approach enables one to investigate the prevalence of symptoms across different cohorts of patients. At individual level, the new approach enables one to identify patients with poor QoV over time. This study highlights some of the potential shortcomings associated with the current use of Rasch analysis to validate questionnaires.

27 November 2020 in Photonics
Verified
Journal Article
Open access
PDF file
SASamuel Arba-Mosquera
Samuel Arba-Mosquera
SVShwetabh Verma
Shwetabh Verma
SAShady Awwad
Shady Awwad
(1) Background: The purpose of the study is to present a simple theoretical account of the effect of translation of coma and spherical aberrations (SA) on refractive error and higher order aberrations. (2) Methods: A computer software algorithm was implemented based on previously published methods. The effect of translation (0 to +1 mm) was analyzed for SA (0 to +2 µm) and coma (0 to +2 µm) for a circular pupil of 6 mm, without any rotation or scaling effect. The relationship amongst Zernike representations of various aberrations was analyzed under the influence of translation. (3) Results: The translation of +0.40 µm of SA (C[4,0]) by +0.25 mm with a pupil diameter of 6mm resulted in induction of tilt (C[1,1]), −0.03D defocus (C[2,0]), +0.03D astigmatism (C[2,2]) and +0.21 µm coma (C[3,1]). The translation of +0.4 µm of coma (C[3,1]) by +0.25 mm with a pupil diameter of 6 mm resulted in induction of tilt (C[1,1]), −0.13D defocus (C[2,0]) and +0.13D astigmatism (C[2,2]). A theoretical quantitative relationship between SA, coma, astigmatism and defocus is presented under the influence of translation. (4) Conclusion: The results can act as a guide for the clinician, in order to readily assess theoretical impact of wavefront map translation from pupil center to the visual axis. The resultant refractive coupling has to be taken into consideration especially when treating eyes with an abnormal corneal shape and/or large pupil center to corneal vertex chord.

7 November 2024 in Photonics
Verified
Journal Article
Open access
PDF file
SVShwetabh Verma
Shwetabh Verma
SASamuel Arba-Mosquera
Samuel Arba-Mosquera
(1) Background: Ultrashort high-energy laser pulses may cause interaction mechanisms, including photodisruption and plasma-induced ablation in the medium. It is not always easy to distinguish between these two processes, as both interaction mechanisms rely on plasma generation and overlap. The purpose of this paper is to discuss prominent cavitation bubble models describing photodisruption and plasma-induced ablation and to explore their nature for different threshold energies. This exploration will help to better distinguish the two interaction mechanisms. As a second aim, we present an alternative model for the low-energy regime close to the laser-induced optical breakdown (LIOB) threshold, representing the phenomenological effect of the plasma-induced ablation regime. (2) Methods: The cavitation bubble models for photodisruption and plasma-induced ablation were used to calculate the bubble radius for a series of threshold energies (ETh = 30, 50, 70, and 300 nJ) that loosely represent commercial systems currently used in ultrashort-pulse tissue ablation. Taking a photodisruption model coefficient commonly used in the literature, the root mean square error between the two interaction models was minimized using the generalized reduced gradient fitting method to calculate the optimum scaling factors for the plasma model. The refined models with optimized coefficients were compared for a range of pulse and threshold energies. (3) Results: For low ETh (30, 50, and 70 nJ), the plasma-induced ablation model dominates for low energies that are close to the threshold energy. The photodisruption model dominates for high energies that are well above the threshold energy. At very high pulse energies, for all the simulated cases, the photodisruption model transitions and crosses over to the plasma-induced ablation model. The cross-over points from which the photodisruption model dominates tend to be reduced for larger ETh. A new universally applicable model for plasma-induced ablation has been hypothesized that considers the cavitation bubble volume and potentially better explains the bubble dynamics during intrastromal processes. (4) Conclusions: This theoretical exploration and the comparison of the outcomes to empirical data substantiate that inadvertently using the photodisruption model to explain the cavitation bubble dynamics for the entire spectrum of pulse energies and laser systems might provide erroneous estimates of cavitation bubble sizes. A reliable estimate of the true size (the maximum radius) of the cavitation bubble can be reasonably retrieved as the maximum predicted size from the fit of the photodisruption model and the newly proposed plasma-induced ablation model at any given pulse energy.

22 November 2019 in Lasers in Surgery and Medicine
Verified
Journal Article
Open access
PDF file
SVShwetabh Verma
Shwetabh Verma
TKTobias Kehrer
Tobias Kehrer
JHJürgen Hesser
Jürgen Hesser
SASamuel Arba-Mosquera
Samuel Arba-Mosquera
Background and Objectives: To analyze the impact of humidity and temperature on excimer laser ablation of polyethylene terephthalate (PET), polymethylmethacrylate (PMMA) and porcine corneal tissue, and an ablation model to compensate for the temperature and humidity changes on ablation efficiency.Study Design/Materials and Methods: The study was conducted using an AMARIS 1050RS (Schwind eye‐tech‐solutions) placed inside a climate chamber at ACTS. Ablations were performed on PET, PMMA, and porcine cornea. The impact of a wide range of temperature (~18°C to ~30°C) and relative humidity (~25% to ~80%) on laser ablation outcomes was tested using nine climate test settings. For porcine eyes, change in defocus was calculated from the difference of post‐ablation to pre‐ablation average keratometry readings. Laser scanning deflectometry was performed to measure refractive change achieved in PMMA. Multiple linear regression was performed using the least square method with predictive factors: temperature, relative humidity, time stamp. Influence of climate settings was modeled for pulse energy, pulse fluence, ablation efficiency on PMMA and porcine cornea tissue.Results: Temperature changes did not affect laser pulse energy, pulse fluence (PET), and ablation efficiency (on PMMA or porcine corneal tissue) significantly. Changes in relative humidity were critical and significantly affected laser pulse energy, high fluence and low fluence. The opposite trend was observed between the ablation performance on PMMA and porcine cornea.Conclusions: The proposed well‐fitting multi‐linear model can be utilized for compensation of temperature and humidity changes on ablation efficiency. Based on this model, a working window for optimum operation has been found (temperature 18°C to 28°C and relative humidity 25% to 65%) for a maximum deviation of ±2.5% in ablation efficiency in PMMA and porcine corneal tissue. Lasers Surg. Med. © 2019 The Authors. Lasers in Surgery and Medicine Published by Wiley Periodicals, Inc.