Introduction: Sepsis, a leading cause of death in critically ill patients, is the result of complex interactions between the infecting microorganisms and the host responses that influence clinical outcomes. We evaluated the prognostic value of presepsin (sCD14-ST), a novel biomarker of bacterial infection, and compared it with procalcitonin (PCT). Methods: This is a retrospective, case–control study of a multicenter, randomized clinical trial enrolling patients with severe sepsis or septic shock in ICUs in Italy. We selected 50 survivors and 50 non-survivors at ICU discharge, matched for age, sex and time from sepsis diagnosis to enrollment. Plasma samples were collected 1, 2 and 7 days after enrollment to assay presepsin and PCT. Outcome was assessed 28 and 90 days after enrollment. Results: Early presepsin (day 1) was higher in decedents (2,269 pg/ml, median (Q1 to Q3), 1,171 to 4,300 pg/ml) than in survivors (1,184 pg/ml (median, 875 to 2,113); P = 0.002), whereas PCT was not different (18.5 μg/L (median 3.4 to 45.2) and 10.8 μg/L (2.7 to 41.9); P = 0.31). The evolution of presepsin levels over time was significantly different in survivors compared to decedents (P for time-survival interaction = 0.03), whereas PCT decreased similarly in the two groups (P = 0.13). Presepsin was the only variable independently associated with ICU and 28-day mortality in Cox models adjusted for clinical characteristics. It showed better prognostic accuracy than PCT in the range of Sequential Organ Failure Assessment score (area under the curve (AUC) from 0.64 to 0.75 vs. AUC 0.53 to 0.65). Conclusions: In this multicenter clinical trial, we provide the first evidence that presepsin measurements may have useful prognostic information for patients with severe sepsis or septic shock. These preliminary findings suggest that presepsin may be of clinical importance for early risk stratification.
In 2010, the EUPHAS 2 collaborative group created a registry with the purpose of recording data from critically ill patients suffering from severe sepsis and septic shock treated with polymyxin-B hemoperfusion (PMX-HP) for endotoxin removal. The aim of the registry was to verify the application of PMX-HP in the daily clinical practice. The EUPHAS 2 registry involved 57 centers between January 2010 and December 2014, collecting retrospective data of 357 patients (297 in Europe and 60 in Asia) suffering from severe sepsis and septic shock caused by proved or suspected infection related to Gram negative bacteria. All patients received atleast one cycle of extracorporeal endotoxin removal by PMX-HP. Septic shock was diagnosed in 305 (85.4 %) patients. The most common source of infection was abdominal (44.0 %) followed by pulmonary (17.6 %). Gram negative bacteria represented 60.6 % of the pathogens responsible of infection. After 72 h from the first cycle of PMX-HP, some of the SOFA score components significantly improved with respect to baseline: cardiovascular (2.16 ± 1.77 from 3.32 ± 1.29, p < 0.0001), respiratory (1.95 ± 0.95 from 2.40 ± 1.06, p < 0.001) and renal (1.84 ± 1.77 from 2.23 ± 1.62, p = 0.013). Overall 28-day survival rate was 54.5 % (60.4 % in abdominal and 47.5 % in pulmonary infection). Patients with abdominal infection treated with PMX-HP within 24 h from the diagnosis of septic shock had a 28-day survival rate of 64.5 %. Patients showing a significantly cardiovascular improvement after PMX-HP had a 28-survival rate of 75 % in comparison to the 39 % of patients who did not (p < 0.001). Cox regression analysis found the variation of cardiovascular, respiratory and coagulation SOFA to be independent covariates for 28-day survival. In European patients were observed a higher 28-day (58.8 vs. 34.5 %, p = 0.003), ICU (59 vs. 36.7 %, p = 0.006) and hospital survival rate (53.2 vs. 35 %, p = 0.02) than in Asian patients. However, the two populations were highly heterogeneous in terms of source of infection and severity scores at admission. The EUPHAS 2 is the largest registry conducted outside Japan on the clinical use of PMX-HP in septic patients. Data analysis confirmed the feasibility of PMX-HP to treat septic patients in daily clinical practice, showing clinical benefits associated with endotoxin removal without significant adverse events related to the extracorporeal technique.
The synergic combination of D-dimer (as proxy of thrombotic/vascular injury) and static compliance (as proxy of parenchymal injury) in predicting mortality in COVID-19-ARDS has not been systematically evaluated. The objective is to determine whether the combination of elevated D-dimer and low static compliance can predict mortality in patients with COVID-19-ARDS. A “training sample” (March–June 2020) and a “testing sample” (September 2020–January 2021) of adult patients invasively ventilated for COVID-19-ARDS were collected in nine hospitals. D-dimer and compliance in the first 24 h were recorded. Study outcome was all-cause mortality at 28-days. Cut-offs for D-dimer and compliance were identified by receiver operating characteristic curve analysis. Mutually exclusive groups were selected using classification tree analysis with chi-square automatic interaction detection. Time to death in the resulting groups was estimated with Cox regression adjusted for SOFA, sex, age, PaO2/FiO2 ratio, and sample (training/testing). “Training” and “testing” samples amounted to 347 and 296 patients, respectively. Three groups were identified: D-dimer ≤ 1880 ng/mL (LD); D-dimer > 1880 ng/mL and compliance > 41 mL/cmH2O (LD-HC); D-dimer > 1880 ng/mL and compliance ≤ 41 mL/cmH2O (HD-LC). 28-days mortality progressively increased in the three groups (from 24% to 35% and 57% (training) and from 27% to 39% and 60% (testing), respectively; p < 0.01). Adjusted mortality was significantly higher in HD-LC group compared with LD (HR = 0.479, p < 0.001) and HD-HC (HR = 0.542, p < 0.01); no difference was found between LD and HD-HC. In conclusion, combination of high D-dimer and low static compliance identifies a clinical phenotype with high mortality in COVID-19-ARDS.
We report the peculiar case of a patient with a retained large epidural catheter fragment, incidentally found 12 years after its placement. Our primary aim is to emphasize how the breakage and retention of even exceptionally large portions of this device can go undetected. The patient can be completely asymptomatic and, with no clue that such a foreign body exists, the presentation of its potential complications can be subtle and misleading. To our knowledge, this is the first reported case of the incidental discovery of such a large fragment so many years after its placement. No consensus exists about how to handle this complication, therefore our report adds to the amount of available evidence. A 53-year-old caucasian female with a history of diverticulitis requiring multiple hospitalizations underwent laparoscopic sigmoidectomy. The early postoperative period was complicated by peritonitis, demanding an urgent “second-look” exploratory laparoscopy. Nine days post-operatively, a filiform metallic object in the upper-quadrant was noted on x-ray. No epidural had been placed for either one of her recent surgeries. Given the patient’s history, the object was initially thought to be a retained surgical sponge. Previous studies, however, showed that the same image was already present preoperatively. Upon further questioning, the patient reported an epidural being placed twelve years before, at the time of her pregnancy. No mention of breakage had been made to her at that time, nor a retained foreign body was ever reported afterwards, despite her many imaging exams. She also never experienced any symptoms. A 15 cm fragment of a wire-reinforced catheter was surgically retrieved under local anesthesia and fluoroscopic guidance. Breakage of the epidural catheter with fragment retention is a known complication of this device, possibly leading to devastating sequelae. The fragment can go undetected for years. In this case our finding was incidental and the patient was asymptomatic. However, in the event a neurologic complication arose, the identification of the unknowingly retained epidural as the causative agent could have been difficult and delayed, with potential harm to the patient.