Background: In this study, we compare the 12-month results of eyes that underwent ab externo, open-conjunctival XEN45 gel stent placement with mitomycin C (MMC) with and without the intraoperative addition of Ologen collagen matrix (XEN45 and XEN45 + Ologen groups, respectively). Methods: Intraocular pressure (IOP) measurements were recorded postoperation at 1 month, 3 months, 6 months, and 9 months, and 12 months, and IOP reduction, reduction in number of IOP-lowering medications, and success rate were compared between XEN45 and XEN45 + Ologen groups. A complete success was defined as a ≥20% drop from baseline IOP at 12 months without the use of medications and without any of the following: an additional procedure (e.g., needling), a recorded IOP ≥ 21 mm Hg at two consecutive visits, or the occurrence of catastrophic events (e.g., no light perception (NLP)). A qualified success was defined as an IOP reduction of ≥20% from baseline with the use of medications. We included 145 eyes with at least 1 month of follow-up data, 46 in the XEN45 group and 99 in the XEN45 + Ologen group. Of these, 113 eyes had 12 months of follow-up data comprising 41 XEN45 eyes and 72 XEN45 + Ologen eyes. Results: There were no significant differences in the IOP change from baseline between XEN45 and XEN45 + Ologen groups except at the 3-month postop timepoint (p < 0.05). At the 12-month follow-up, 41.5% (17/41) of XEN45 eyes and 52.8% (38/72) of XEN45 + Ologen eyes met complete or qualified success criteria. Conclusions: No significant differences in success rate and decrease in the number of IOP-lowering medications from baseline were identified between XEN45 and XEN45 + Ologen groups.
1 February 2026 in Journal of Cataract & Refractive Surgery
This study evaluated the effectiveness of surgeon self-reporting and anterior vitrector equipment billing in identifying intraoperative posterior capsular tears (PCT) with vitreous loss during cataract surgery. A total of 19,258 cataract surgeries performed over six years at the John A. Moran Eye Center were analyzed, with 343 potential complications identified through billing or self-reporting, and 193 confirmed PCT cases based on chart review. Billing data captured 83.9% of PCTs but lacked specificity, including many non-PCT uses of anterior vitrectomy. Surgeon self-reporting was highly specific, with 100% accuracy according to operative reports, but detected only 58.5% of total PCT cases. The findings highlight the strengths and limitations of both methods-billing is sensitive but overinclusive, while self-reporting is accurate but underutilized. Neither method alone was sufficient to identify all complications, emphasizing the need for a standardized, comprehensive approach to intraoperative complication monitoring to enhance patient safety and quality assurance in ophthalmic surgery.