Broadband spectral measurements of the ballistic transmission of scattering samples are challenging. The presented work shows an approach that includes a broadband system and an automated adjustment unit for compensation of angular distortions caused by non-plane-parallel samples. The limits of the system in terms of optimal transmission and detected forward scattering influenced by the scattering phase function are investigated. We built and validated a setup that measures the collimated transmission signal in a spectral range from 300 nm to 2150 nm. The system was validated using polystyrene spheres and Mie calculations. The limits of the system in terms of optimal transmission and detected forward scattering were researched. The optimal working parameters of the system, analyzed by simulations using the Monte Carlo method, show that the transmission should be larger than 10% and less than 90% to allow for a reliable measurement with acceptable errors caused by noise and systematic errors of the system. The optimal transmission range is between 25% and 50%. We show that the phase function is important when considering the accuracy of the measurement. For strongly forward-scattering samples, errors of up to 80% can be observed, even for a very small numerical aperture of , as used in our experimental system. We also show that errors increase with optical thickness as the ballistic transmission decreases and the multiscattered fraction increases. In addition, errors caused by multiple reflections in the sample layer were analyzed and also classified as relevant for classical absorption spectroscopy.
Manipulating the wavefront of coherent light incident on scattering media to enhance the imaging depth, sensitivity, and resolution is a common technique in biomedical applications. Local phase variations cause changes in the interference and can be used to create a focus inside or behind a scattering medium. We use wavefront shaping (WFS) to force constructive interference at an arbitrary location. The amount of light transmitted into a given region strongly depends on the scattering and absorption characteristics. These are described by their respective coefficients and and the scattering phase function. Controlling the scattering and absorption coefficients, we study the behavior of wavefront shaping and the achievable intensity enhancement behind volume scattering media with well-defined optical properties. The phantoms designed in this publication are made of epoxy resin. Into these epoxy matrices, specific amounts of scattering and absorbing particles, such as titanium dioxide pigments and molecular dyes, are mixed. The mixture obtained is filled into 3D-printed frames of various thicknesses. After a precise fabrication procedure, an integrating sphere-based setup characterizes the phantoms experimentally. It detects the total hemispherical transmission and reflection. Further theoretical characterization is performed with a newly developed hybrid method. This method senses the flux of light into a particular angular range at the lower boundary of a slab. The calculations are performed without suffering from ringing and fulfill the exact boundary conditions there. A decoupled two-path detection system allows for fast optimization as well as sensitive detection. The measurements yield results that agree well with the theoretically expected behavior.
A measurement system for a distance insensitive acquisition of the reflectance from turbid media is presented. The geometric relationships of the detection unit are discussed theoretically and subsequently verified using Monte Carlo simulations. In addition, an experimental setup is presented to prove the theoretical considerations and simulations. The use of the presented measurement system allows measurements of the reflectance in a distance range of approximately with a deviation of less than for highly scattering media. This contrasts with the use of a fiber in a classical detection unit placed at a defined angle and position relative to the sample surface, which results in deviations of in the measured reflectance over the same distance range.
Coherent backscattering is an interference phenomenon that occurs in the backwards direction of the incident illumination. It arises from photons traveling the same path in opposite directions within a scattering medium. Accurately determining the background signal for normalization can be challenging in such measurements. This study investigates the use of a spatial light modulator to control spatial coherence, effectively switching the interference on and off. This approach enables independent, absolute measurements of both the signal and background across the full angular detection range without modifying the experimental setup. We demonstrate this method experimentally, highlighting the importance of accurate background determination in coherent backscattering measurements using a Fourier-based setup. Additionally, we demonstrate that measurements normalized to the correct background closely match Monte Carlo simulations of the coherent backscattering signal.