Detecting antibiotics in the milk supply chain is crucial to protect humans from allergic reactions, as well as preventing the build-up of antibiotic resistance. The dairy industry has controls in place at processing facilities, but controls on dairy farms are limited to manual devices. Errors in the use of these manual devices can result in severe financial harm to the farms. This illustrates an urgent need for automated methods of detecting antibiotics on a dairy farm, to prevent the shipment of milk containing antibiotics. This work introduces the microchip capillary electrophoresis dairy device, a low-cost system that utilizes microchip capillary electrophoresis as well as fluorescence spectroscopy for the detection of ciprofloxacin contained in milk. The microchip capillary electrophoresis dairy device is operated under antibiotic-absent conditions, with ciprofloxacin not present in a milk sample, and antibiotic-present conditions, with ciprofloxacin present in a milk sample. The response curve for the microchip capillary electrophoresis dairy device is found through experimental operation with varied concentrations of ciprofloxacin. The sensitivity and limit of detection are quantified for the microchip capillary electrophoresis dairy device.
Antibiotics are classes of antimicrobial substances that are administered widely in the field of veterinary science to promote animal health and feed efficiency. Cattle-administered antibiotics hold a risk of passing active residues to milk, during the milking process. This becomes a public health concern as these residues can cause severe allergic reactions to sensitive groups and considerable economic losses to the farmer. Hence, to ensure that the produced milk is safe to consume and adheres to permissible limits, an on-farm quick and reliable test is essential. This study illustrates the design and development of a microfluidic paper biosensor as a proof-of-concept detection system for gentamicin in milk. Localized surface plasmon resonance (LSPR) properties of gold nanoparticles have been explored to provide the user a visual feedback on the test, which was also corroborated by RGB analysis performed using Image J. The assay involves the use of a short stretch of single stranded DNA, called aptamer, which is very specific to the gentamicin present in the milk sample. The camera-based LOD for the fabricated paper device for milk samples spiked with gentamicin was calculated to be 300 nM, with a reaction time of 2 min.
Terahertz spectral acquisition has a fundamental limitation in implementation due to long experimental acquisition time. The long experimental acquisition time in terahertz spectral acquisition is a result of the required high integration time associated with usable dynamic range signals acquired through delay stage interferometry. This work evaluates the effectiveness of a non-linear version of the Kalman Filter, known as the extended Kalman filter (EKF), and the recently developed extended sliding innovation filter (ESIF), for increasing dynamic range in terahertz spectral acquisition. The comparison establishes that the EKF and ESIF can reduce integration time (time constant) of terahertz spectral acquisition, with EKF reducing the integration time by a factor of 23.7 for high noise signals and 1.66 for low noise signals to achieve similar dynamic ranges. The EKF developed in this work is comparable to a nominal application of wavelet denoising, conventionally used in terahertz spectral acquisitions. The implementation of this filter addresses a fundamental limitation of terahertz spectral acquisition by reducing acquisition time for usable dynamic range spectra. Incorporating this real-time post-processing technique in existing terahertz implementations to improve dynamic range will permit the application of terahertz spectral acquisition on a wide array of time sensitive systems, such as terahertz reflection imaging, and terahertz microfluidics. This is the first implementation, to our knowledge, of Kalman filtering methods on terahertz spectral acquisition.
Terahertz (THz) technology has been developed to meet advancements in spatial light modulation of frequencies in the THz regime, where fast modulation techniques designed for optical wavelengths perform poorly. Applications of THz frequencies in nondestructive imaging and quality testing have been thoroughly explored—specifically, polarization-resolved measurements can be scanned to image fiber anisotropy and birefringence in wood products and 3-D printed materials and strains in plastics. There is a need to explore faster image acquisition techniques, such as single-pixel imaging via spatial light modulation, to realize fast polarization-resolved THz imagers. Such spatial light modulators are vital for patterning the THz imaging beam before interacting with the sample to reconstruct the response of the sample with a single detector via compressive sensing algorithms. In this work, a spatial polarization modulation scheme is employed using wire grid polarizer (WGP) mask patterns to acquire polarization-resolved images of polarizing samples at 0.1 THz. A laser ablation technique is used to fabricate 8 × 8 WGP masks with randomly vertical and horizontal wire grids to pattern the imaging beam and enable orthogonal polarization images. With various sampling amounts, 8 × 8 polarization images are successfully reconstructed for polarizing samples of low and high spatial frequencies.
10 September 2018 in IEEE Transactions on Instrumentation and Measurement
Hyperspectral imaging (HSI) is an emergent instrumentation technology with great potential in many applications, due to its ability to measure important spectral features. However, the widespread adoption of HSI requires the development of accessible (i.e., inexpensive and uncomplicated) HSI instrumentation architectures. In this paper, we present, design, develop, and evaluate an accessible HSI instrumentation architecture, with snapshot operation, based on the integration of readily available components and frequency multiplexing with Fourier analyses. In the experimental work, an incident image beam is divided into spatial image channels, each with an assigned dynamic binary code via a dynamic coded aperture. This dynamic coded aperture is constructed from repurposed diffractive optical disc technologies and is patterned with strategic opaque and transparent regions. When it is rotated by a motor, dynamic binary codes are used, along with Fourier analyses, to identify the diffraction of each spatial image channel. The spatially overlapped spectra from the diffraction are directed onto a charge-coupled device sensor, and each spatial image channel is distinguished through Fourier analyses. The resulting Fourier amplitude spectra are transformed into corresponding functions of wavelength, and this transformation is based on the experimental instrumentation geometry. The performance of the HSI instrumentation architecture is evaluated using a comparison with data from a commercial spectrometer. The presented HSI instrumentation architecture can be adapted for 2-D operation. Ultimately, the presented HSI instrumentation architecture can benefit regions of the world that have limited financial resources and a need for accessible HSI technologies.